Liquid phase carbon infrared analyzerMeasurement range:
High carbon pool: 0.001-99.99%
Low carbon pool: 0.0001-0.3%
Low sulfur: 0.0001-0.3%
Liquid phase carbon infrared analyzerPerformance characteristics:
A、 High power high-frequency furnace: adjustable over 3.2KW.
B、 Synchronous reverse blowing dust removal.
C、 Independent data collection: Independent analog-to-digital (A/D) conversion system. Optimization of sampling frequency. Each testing unit is relatively independent and has no shared relationship.
D、 Narrowband filter and infrared detector solid-state cone sensor, with high sensitivity, output signal temperature change rate not exceeding 0.01%, good stability, high accuracy, and long service life. Imported synchronous cutting motor, capable of continuous operation for 100000 hours.
E、 Furnace head constant temperature heating technology: eliminates adsorption, does not require saturation treatment of the gas path after startup, and has the same stability regardless of interval or continuous measurement, ensuring furnace dryness and avoiding the influence of moisture on the sulfur measurement structure.
F、 Efficient filter: Ultra microporous metal filter (pore size less than 0.5 microns), which can effectively prevent dust from entering the detection room and can be used for a long time without clogging (keeping it dry). Start up and make samples without the need for waste sample saturation. Other manufacturers require three or more waste samples to be saturated (in fact, it is used to block the holes with the dust generated during the sampling process, as their metal filter mesh has a pore size greater than 5 microns. This not only wastes materials but also affects the environment - dust is discharged into the air with the carrier gas during the combustion process, as the mixed gas generated during the sampling process is vented to the atmosphere).
G、 Continuous testing of 20 samples meets the JJG395-2016 standard (international standards require continuous testing of 11 samples, while JJG395-2016 requires continuous testing of 7 samples).
H、 Linearization "mathematical model: achieving non segmented, non inflection point compensation, and no range switching, making the instrument have an almost ideal ultra wide linear range.
J、 Multi stage purification device: can heat the purification agent according to the situation. Dealing with harmful gases. Independent exhaust gas purification device.
K、 Durable and sturdy, this instrument has a normal lifespan of over 10 years under normal circumstances (without human intervention or uncontrollable factors).
L、 Oscilloscope function: It can accurately determine the faults of the light source, preamplifier, infrared cell, and related components based on the amplitude and waveform changes of the signal voltage, facilitating timely maintenance.
M、 The sensor is treated with anti-oxidation, without peeling, discharging, or sparking.
N、 Independent design and professional filtration have solved the problem of corrosive substances (including various acids, bases, salts, corrosive gases, oxides, dust, etc.) corroding detection components. This function is limited to XRCS-7A and XRCS-7H only.
P. The operating software on the Windows platform has a fully Chinese interface, rich software, and * functions.
Q、 Environmental Protection: Efficient metal filters and multi-stage purification devices ensure that the exhaust gas is dust-free and free of harmful gas emissions.
U、 The furnace body is equipped with a built-in dust collection box, achieving integrated dust removal and collection. It can continuously collect the dust generated by burning 500 samples without external dust collection devices or vacuum cleaner noise. No dust clogging of pipelines, valves, and other defects.