CHILLROW data center row air conditioning is suitable for large and medium-sized data centers, as well as various electronic equipment rooms. Installed between cabinets, adjacent to the heat source, the high-density heat in the cabinets is carried away by horizontal air supply, resulting in high efficiency of air supply and heat exchange. By using EC fans, the energy efficiency ratio of the unit can be improved, and the air supply and pressure can be easily adjusted. This series of units adopts height adjustable support feet and casters for easy movement. CHILLROW includes two cooling methods, including direct evaporative air cooling (DXA) and single coil tube chilled water (CW). The direct evaporative air-cooled type adopts a variable frequency compressor, which can achieve stepless speed regulation and adjust the cooling capacity according to demand.
High Efficiency and Energy Saving
DC variable frequency scroll compressor, which can dynamically adjust the cooling output within the range of 20% to 100% and cool as needed;
Efficient and low-noise post tilt EC centrifuge, adjusting speed output according to real-time thermal load changes to achieve maximum energy savings;
Electronic expansion valve, with faster response speed, more precise flow regulation, and more energy-efficient when combined with variable frequency compressors;
Variable frequency outdoor unit, which quickly and smoothly adjusts the speed output according to system pressure changes, achieving high energy efficiency operation;
The use of high-efficiency internally threaded copper tubes and aluminum fin evaporators with windows coated with hydrophilic layers significantly improves heat transfer efficiency;
Two stage evaporator design, with a water tray added in the middle of the evaporator to effectively prevent water blowing;
Efficient and environmentally friendly refrigerant R410A, in line with international green and environmentally friendly refrigerant requirements;
The air conditioner adopts a high return temperature design to further improve cooling efficiency.
safe and reliable
Using rigorously certified high-quality components to enhance reliability from the source;
DC frequency conversion technology, with low starting current, reduces the impact on the power grid;
Accurately control the temperature and humidity of the supply/return under low load;
Intelligent monitoring of power supply voltage, power supply frequency, and three-phase imbalance;
The air conditioner comes standard with an oil separator to prevent compressor damage due to oil shortage;
Standard one-way valve to prevent damage caused by refrigerant migration to the compressor during shutdown;
Standard liquid sight glass, which can visually and effectively check the status of refrigerant in the air conditioning system pipeline;
The product has undergone rigorous and repeated testing and verification, with high standard requirements and high-quality delivery.
intelligent control
Advanced control system intelligently manages components such as compressors/expansion valves/machines, adjusting cooling capacity and output as needed;
7-inch high-end true color capacitive touch screen, supporting multiple display modes for graphic status and temperature and humidity curves;
Adopting a fast and flexible CAN communication protocol, it can support group control and management of no less than 64 units;
At least 10 temperature sensors can be connected externally to accurately sense changes in the temperature field;
Standard RS485 interface, supports optional SNMP interface; Multi level password protection and hierarchical authorization management.
flexible configuration
High cooling density, with a comprehensive coverage of cooling capacity ranging from 12.5-60kW;
Standard electrode humidifier, supporting optional wet film humidifier;
Optional centralized outdoor unit, using V-shaped heat exchanger, with small footprint and large heat transfer capacity;
Support optional upper pipe/upper drainage to meet the needs of different scenarios;
Optional grille for left and right delivery needs;
Optional fluorine pump natural cooling module; Optional dual power input.