- Phone
-
Address
Building 4, Lane 177, Fulian 2nd Road, Baoshan District, Shanghai
Shanghai Jixin Industrial Development Co., Ltd
Building 4, Lane 177, Fulian 2nd Road, Baoshan District, Shanghai
Li Yin Noise MeterIt has the function of measuring sound, equivalent noise level, maximum and minimum noise levels, as well as time rate noise level and noise exposure level, and recording the measurement results in the main memory or SD card. Using a single range without the need to switch ranges. When installing the windproof cover, it can also meet the specifications.
Product Features:
It has the function of measuring sound, equivalent noise level, maximum and minimum noise levels, as well as time rate noise level and noise exposure level, and recording the measurement results in the main memory or SD card.
Using a single range without the need to switch ranges.
When installing the windproof cover, it can also meet the specifications.
Use a 3-inch TFT color LCD with backlight and equip it with a touch screen.
The output port is equipped with AC output port, DC output port, RS-232C output port, and USB port.
The body has IP54 (excluding microphone) waterproof performance and can be used for outdoor measurements.
Product Configuration:
Handbag x 1 portable box x 1 windproof cover x 1 instruction manual x No. 15 dry battery x 4 windproof cover detachment rubber x 1
Li Yin Noise MeterTechnical parameters:
| model | RION NL-42 ordinary sound level meter | RION NL-52 Precision Sound Level Meter | RION NL-62 Precision Sound Level Meter | |
| Approval Number | No. SLS111 | No. SLF112 | No. SLF123 | |
| Implementation Standard | IEC 61672-1:2002 Class 2JIS C 1509-1:2005 Class 2ANSI S1.4-1983 Type 2ANSI S1.4-1985 Type 2ANSI S1.43-1997 Type 2 | IEC 61672-1:2002 Class 1JIS C 1509-1:2005 Class 1ANSI S1.4-1983 Type 1ANSI S1.4-1985 Type 1ANSI S1.43-1997 Type 1 | IEC 61672-1:2002 Class 1JIS C 1509-1:2005 Class 1ANSI S1.4-1983 Type 1ANSI S1.4-1985 Type 1ANSI S1.43-1997 Type 1IOS 7196:1995 | |
| microphone | model | UC-52 | UC-59 | UC-59L |
| sensitivity | -33dB | -27dB | -27dB | |
| Self noise level | A weighting | Not exceeding 19dB | Not exceeding 17dB | Not exceeding 17 dB |
| C weighting | Not exceeding 27dB | Not exceeding 25dB | Not exceeding 25 dB | |
| Z weighting | Not exceeding 32dB | Not exceeding 30dB | Not exceeding 35 dB | |
| G weighting | Not exceeding 42 dB | |||
| Frequency measurement range | 20Hz~8KHz | 20Hz~20KHz | 1Hz~20kHz | |
| Additional operations | As a function of measuring simultaneously with computation, any of the following measurements can be implemented: C-weighted peak sound level LcpeakZ weighted peak sound level Lzieq * 2C weighted time averaged sound level Lceq. Since the frequency weighting of the additional computation is linked to the frequency weighting of the secondary channel, when the secondary channel is C-weighted (Z-weighted), it is possible to choose the additional computation Lceq and Lcpeak (Lzpeak) | As a function of measuring simultaneously with computation, any of the following measurements can be implemented: C-weighted peak sound level, LcpeakG weighted time average sound level, LGeqZ weighted peak sound level, Lzieq * 2C weighted time average sound level, Lceq. Since the frequency weighting of the additional computation is linked to the frequency weighting of the secondary channel, when the secondary channel is C weighted (Z weighted), it is possible to choose the additional computation Lceq and Lcpeak (Lzpeak). ※ Since the frequency weighting of the additional computation is linked to the frequency weighting of the secondary channel, when the secondary channel is A weighted, it is possible to choose LA? Eq or LA? Eq? max, When it calculates weights for C, G, and Z, it is possible to choose to perform additional operations such as LCeq, LCpeak, LGeq, and LZpeak | ||
| range | A weighted 25dB~130dBC weighted 33dB~130dBZ weighted 38dB~130dBC weighted peak sound level 55dB~141dBZ weighted peak sound level 60dB~141dB | A weighted 25dB~138dBC weighted 33dB~138dBG weighted 43dB~138dBZ weighted 50dB~138dBC weighted peak sound level 60dB~141dBZ weighted peak sound level 65dB~141dB | ||
| Measurement function | Weighting characteristics for the selected time The frequency weighting characteristics are measured simultaneously for the following items | |||
| Operation (main channel) | Noise exposure level LE Time averaged sound level Leq Time weighted sound level Lp Time rate sound level Ln (05, 10, 50, 90, 95) Greater by 5 Time weighted sound levels Large value Lmax Time weighted sound level Small value Lmin | |||
| Operation (secondary channel) | Time weighted sound level Lp | |||
| computation time | It can be set to any time through 10 seconds, 1, 5, 10, 15, 30 minutes, 1, 8, 24 hours, and manual operation; Manual calculation time: 24 hours long | |||
| Frequency weighting characteristics | A. C and Z weighting | |||
| Time weighting characteristics | Fast and Slow | |||
| Sound level range switch | None (dynamic range 113dB) | |||
| Bar chart range | Greater 110dB (20-130dB) | |||
| Bar chart switching | The upper and lower limits of the bar chart are set to every 10dB | |||
| Data call out | Browse stored data | |||
| Set Memory | Can save in memory and call up to 5 sets of settings It can be started by setting the files pre stored in the SD card | |||
| waveform | Document format | Uncompressed waveform WAVE file | ||
| Include * 3 | sampling frequency | Choose from 48kHz, 24kHz, 12kHz | ||
| Data length | Select from 24 bits and 16 bits | |||
| output | DC output | By calculating the weighting characteristics of the selected frequency, output a DC signal | ||
| output voltage | When displayed as a full bar chart, it is 2.5V and 25mV/Db | |||
| communication output | By performing calculations to select or select frequency weighting characteristics from A, C, Z, output AC signals | |||
| output voltage | When displayed as a full bar chart, it is 1Vrms (actual value) | |||
| Compare output * 2 | When the collector open circuit output (high input voltage 24V, high current 60mA, allowable loss 300mW) exceeds the set level, it will trip ON | |||
| USB | Connected to a computer, it can be recognized as a removable hard drive and controlled through communication commands | |||
| RS-232C communication | RS-232C communication can be achieved through the use of cables | |||
| Continuous data | instantaneous value | Lp | ||
| Output * 2 | Operational value | Leq,Lmax,Lmin,Lpeak | ||
| output interval | 100ms,1s | |||
| Effective value detection circuit | Digital operation method | |||
| sampling period | Lp.Leq.Le.Lmin.Lpeak: 20.8us (sampling frequency 48KHz) Ln: 100ms | |||
| correction | Measurement method: Electrical calibration is carried out through embedded electrical signals; JIS.IEC: Sound correction through NC-74 | |||
| Calibration function | Windproof cover calibration function, which also complies with JIS C 1509-1. IEC 61672-1 when the windproof cover is installed | |||
| The diffusion sound field calibration function calibrates the frequency weighting in the diffusion sound field to meet the specifications (ANSI S1.4) | ||||
| delay time | Set the time to start measuring after pressing the 'Start' button (OFF, 1, 3, 5, 10 seconds) | |||
| Nearby data deletion function (data deletion function) | When using the PAUSE/CON key to temporarily interrupt the measurement, the data with the traceability setting time from the time of interruption will be excluded from the calculation (OFF, 1, 3, 5 seconds) | |||
| display | TFT color semi transparent LCD display with backlight WQVGA (400 × 240 dots), LCD display with touch screen (electrostatic capacitive) control | |||
| Numerical display update cycle | 1s | |||
| Bar chart update cycle | 100ms | |||
| storage | manual | Record measurement results manually at each address | ||
| Record the number of data | Memory: up to 1000 sets of data SD card: depending on the capacity of the SD card | |||
| automatic | Automatically record the instantaneous value of each set time (Lq mode) and the calculated value of each set time (Leq mode) continuously | |||
| Lp storage cycle | 100ms,200ms,1s,Leq 1s | |||
| Leq operation cycle | 10 seconds, 1, 5, 10, 15, 30 minutes, 1, 8, 24 hours | |||
| measure time | 1000 hours long (depending on the capacity of the SD card) | |||
| Print test results using printer DPU-414 | ||||
| power supply | AC adapter NC-98C, 4 No. 5 dry batteries | |||
| Waterproof and dustproof function * 4 | IP rating: IP54 (excluding microphone part) | |||
| Size | 250 × 76 × 33mm, approximately 400g (including battery) | |||