Level TROLL 400、 500 and 700 water level gaugesProduct Introduction
The water level gauge is sturdy and durable, with accurate data and intuitive software. It can be used for self recording monitoring, long-term online monitoring, and portable measurement to meet different monitoring needs.
Analysis of water layer characteristics: micro water test and pumping test, coastal, tidal, wetland and estuary research, storm surge and flood monitoring, long-term and real-time groundwater and surface water monitoring, mining and remediation, geothermal and drilling development.
Level TROLL 400、 500 and 700 water level gaugesProduct Features
·Easy to operate:In Situ's intuitive software platform and integrated components can shorten training and installation time.Level TROLL series water level gauge and RuggedTable ®systemThe proprietary twist lock connector on ensures accurate deployment.
·Simplified management: With the VuSitu Mobile app, all site information can be integrated onto smart terminals, and site photos and GPS coordinates can be added to the data. Simply connect the instrument to Wireless TROLL Com to easily read data, record data, and download results in a standard universal data file format. Connect to a PC using TROLL Com Cable Connect or Direct Connect, and use Winsitu 5 PC software to create logs, configure instruments, read data, and analyze data.
·Durable and sturdy: The water level gauge can be installed in fresh water, saltwater, and sewage. The sturdy titanium metal sealing structure far exceeds the performance and service life of water level gauges made of other materials.
·Accurate data: High accuracy can be achieved under all working conditions. The sensor is calibrated through 3D and NIST traceable factory calibration within the complete pressure and temperature range. The gauge pressure (ventilation) system can meet the measurement requirements with high accuracy.
·Ultra long battery life: These low-power water level gauges can typically work for 10 years, significantly reducing the number of maintenance and replacement times for users.
Technical Specifications
model |
Level TROLL 400 |
Level TROLL 500 |
Level TROLL 700 |
temperature range1 |
function:-20-80 ℃ (-4-176 ℉) Storage: -40-80 ℃ (-40-176 ℉) Calibration: -5-50 ℃ (23-122 ℉) |
||
diameter |
1.83 cm (0.72 in.) |
||
length |
21.6 cm (8.5 in.) |
||
weight |
124g (0.27lb) |
||
material |
Titanium metalSubject;Delrin®protective cap |
||
output method |
Modbus/RS485、SDI-12、4-20 mA |
||
Battery type and lifespan2 |
3.6V lithium battery; 10 years or 2 million readings |
||
external power supply |
8-36 VDC |
||
|
memory data recording3 data log |
2.0 MB 120,000 50 |
2.0 MB 120,000 50 |
4.0 MB 250,000 50 |
Log Type |
Linear, Fast Linear, and Event |
Linear, Fast Linear, and Event |
Linear, Fast Linear, Linear Average, Event, Ladder Linear, True Logarithmic |
Quickly record the speed |
per second2 items |
per second2 items |
per second4 items |
Fast output rate |
Modbus: 2 per second; SDI-12 and 4-20 mA: 1 per second |
||
Real-time clock |
precise and penetrating1 second/24 hours |
||
pressure sensor |
Titanium metal varistor |
||
scope |
Absolute pressure(Non ventilated) 30 psia:11 m (35ft) 100 psia:60 m (197ft) 300 psia:200 m (658ft) 500 psia:341 m (1120ft) |
Gauge pressure (ventilation) 5psig:3.5 m (11.5ft) 15psig:11 m (35ft) 30psig:21 m (69ft) 100psig :70 m (231ft) 300psig:210 m (692ft) 500psig:351 m (1153ft) |
Absolute pressure(Non ventilated) 30 psia:11 m (35ft) 100 psia:60 m (197ft) 300 psia:200 m (658ft) 500 psia:341 m (1120ft) 1000 psia:693 m (2273ft) Gauge pressure (ventilation) 5psig: 3.5 m (11.5ft) 15psig:11 m (35ft) 30psig:21 m (69ft) 100psig:70 m (231ft) 300psig:210 m (692ft) 500psig:351 m (1153ft) |
peak pressure |
very big2x range; peakgreater than3x range |
||
precision(15℃)4 |
Full range±0.05%(-5-50℃) |
||
Accuracy (Full Scale)5 |
Full range±0.1% |
||
resolution |
Full range± 0.005% or better |
||
unit of measurement |
StressPsi、kPa、bar、mbar、mmHg、inHg、cmH2O、inH2O Water level:in.、ft、mm、cm、m |
||
temperature sensor |
silicon |
||
Accuracy and Resolution |
±0.1℃; 0.01 ℃ or better |
||
unit of measurement |
Celsius or Fahrenheit |
||
Remarks |
1Liquid does not freeze within the temperature range.2The standard battery life when used within the temperature range calibrated at the factory.31 data record=2 parameters recorded by the device within the temperature range of date/time and factory calibration (without line breaks).4Within the pressure range of factory calibration.5Within the pressure and temperature range of factory calibration. |
||