Leakage testing of industrial grade methanol CH3OH detection tube gas detector
Methanol detection tube
The methanol detection tube is a sealed, slender glass tube that presents a specific color due to being filled with specific reagents and coloring agents. When a gas sample containing methanol enters the detection tube, a chemical change occurs, causing a change in color. The scale corresponding to the boundary of observing color changes is the concentration of methanol in the tested sample.
Specification 111:
| Testing Scope | 0.002-0.004% | 0.004-0.02% | 0.02-1.5% | 1.5-4.5% |
| Extraction frequency | 4 times (400ml) | 2 times (200ml) | 1 time (standard) (100ml) | 1/2 time (50ml) |
| correction factor | 1/9 | 1/5 | 1 | 3 |
| Detection Time | 4 points | 2 points | 1 point | 30 seconds |
Testing line: 0.0004% (pumping 4 times)
Color change: light red, light blue
Temperature and humidity correction: Temperature correction is required
Validity period: 3 years
Reaction principle:CH3OH + Cr6+(Light red)+H2SO4Cr3+(Light Blue)
111L specification:
| Testing Scope | 20-40ppm | 40-1000ppm | |
| Extraction frequency | 2 times (200ml) | 1 time (standard) (100ml) | |
| correction factor | 1/2 | 1 | |
| pumping time | 6 minutes | 3 minutes |
Detection line: 15ppm (pumping twice)
Color change: light red, light blue
Temperature and humidity correction: Temperature correction is required
Relative standard deviation: 15% (40-200ppm), 10% (200-1000ppm)
Validity period: 3 years
reaction principle:CH3OH+Cr6++H2SO4Cr3+
Other substances that can be detected by this detection tube:
| substance | conversion factor | Extraction frequency | Testing Scope |
| chloroethanol | According to the conversion table | 3 times | 80-200ppm |
111LL specification:
| Testing Scope | 2-20ppm | 20-56ppm | |
| Extraction frequency | 4 times (standard) (400ml) | 2 times (200ml) | |
| correction factor | 1 | 2.8 | |
| pumping time | 8 minutes | 4 minutes |
Detection line: 0.2ppm (pumping 4 times)
Color change: light yellow, light blue-green
Temperature and humidity correction: Temperature correction is required
Relative standard deviation: 15% (2-5ppm), 10% (5-20ppm)
Validity period: 2 years
reaction principle:CH3OH+Cr6++H2SO4Cr3+
111TP specification:
| Testing Scope | 20-300ppm |
| Flow setting | 50ml/min |
| correction factor | 1 |
| Detection Time | 10 points |
Testing line: 3ppm (500ml)
Color change: light yellow, light blue-green
Temperature and humidity correction: Temperature correction is required
Relative standard deviation: 10% (20-100ppm), 5% (100-300ppm)
Validity period: 24 months
reaction principle:CH3OH+Cr6++H2SO4Cr3+