-
E-mail
315506928@qq.com
-
Phone
18641536633
-
Address
No. 9 Xingyuan Street, Industrial Park, Tongxing Town, Zhen'an District, Dandong City
Dandong Haoyu Technology Co., Ltd
315506928@qq.com
18641536633
No. 9 Xingyuan Street, Industrial Park, Tongxing Town, Zhen'an District, Dandong City
HYL-1080 typeLaser Particle Size TesterIt is a new type of laser particle size analyzer, with a testing line of up to 40 nanometers and a main photoelectric receiver consisting of 71 photovoltaic cells. The maximum detection angle is 21.5 °; Non uniformly arranged lateral and backward photoelectric receivers, consisting of 9 photovoltaic cells, with a maximum angle of 135 °. Excellent inverse Fourier transform design, combined with *'s integrated optical path structure, makes the optical path more stable; Long term use without adjustment, advanced mechanical design and processing technology make the structure of the instrument more compact and reasonable, streamlined design, beautiful and elegant, and more convenient to use and maintain; Effective shielding and anti-interference technology make the electrical and other performance of the instrument more stable, the results more accurate, and the repeatability better.
IIHYL-1080 typeLaser Particle Size TesterTechnical Specifications
Test range: 0.04 μ m to 500 μ m
Light source: semiconductor laser (wavelength 635nm, power 3mw, service life over 25000 hours)
Injection method: Wet testing
Sample concentration: 0.5 ‰~1% (depending on the specific gravity, particle size, and refractive index of the sample)
Test time: less than 1 minute/time, excluding sample dispersion time
Scanning speed: 2000 times/second
Repetitive error: ≤ 1%
Power supply: AC 220V ± 10PHz or 60Hz, power: 80W
Microcomputer interface: requires computer cooperation for use, standard RS-232 serial interface
Operating System: Can run on all versions of the Windows operating system
3、 HYL-1080 typeLaser particle size analyzerfeature
(1) HYL-300 type cyclic sample feeder (optional accessory)
The HYL-300 circulating sample feeder has functions of ultrasonic, circulation, stirring, and ultrasonic timing. The circulation system adopts a peristaltic pump method, which does not cause any contamination to the sample and ensures the accuracy of the test data. The HYL-1076 laser particle size analyzer has two injection methods: a micro sample cell and a circulating sample cell. The micro sample cell is specially designed for samples that require organic solvents as the medium; The circulating sample pool is usually used to test samples of water as a medium, and these two injection methods do not need to be exchanged, making them very convenient to use.

(2) Powerful software system with powerful functions
The HYL-1080 laser particle size analyzer system is a high-tech product that integrates optics, mechanics, electronics, and computers. The data processing is completed by computer analysis system software, and the output of test reports is completed by a printer.
(3) Integrated optical path technology
Excellent inverse Fourier transform design, combined with *'s integrated optical path structure, makes the optical path more stable; Long term use, no need for adjustment. Advanced mechanical design and processing technology make the structure of the instrument more compact and reasonable, streamlined design, beautiful and elegant, and easier to use and maintain; Effective shielding and anti-interference techniques make the electrical and other performance of the instrument more stable.

(4) High sensitivity and large angle optoelectronic receiver array
HYL-1080 typeLaser particle size analyzer*The design of the photoelectric receiver array effectively improves the resolution of the instrument. Among them, the main photoelectric receiver has a total of 71 photovoltaic cells, with the largest detection angle reaching 21.5 °; The lateral and backward photoelectric receivers with non-uniform cross arrangement, consisting of 9 photovoltaic cells, have a maximum backward detection angle of 135 °, enabling the testing line to be accurate to 0.04mm.

(5) Long lasting and durable
Adopting a wavelength of 635nm and a power of 3mw semiconductor full laser, the service life is over 25000 hours, effectively improving the usage and storage time of the laser particle size analyzer.
(6) Excellent H. Golub distribution inversion algorithm
The HYL series laser particle size testing system * adopts advanced full Mie scattering theory as the basis, and adopts excellent H. Golub distribution inversion algorithm. Combined with *'s instrument hardware design, it can make the test data more accurate and fast for both single distribution and mixed samples you test.
(7) Flexible output result format
The output format of the report is flexible and can be edited according to the needs of users, including cumulative particle size distribution data and curves, interval particle size distribution data and histograms, and various typical particle size values.
(8) Complies with the standard ISO13320-1
In order to meet users' requirements for traceable accuracy and repeatability, our HYL-1076 laser particle size analyzer * complies with the ISO13320 standard. All laser particle size analyzers have been verified and passed the reference material inspection, making them the high-performance laser particle size analyzers on the market.

HYL-1080 typeLaser particle size analyzerReference Table of Standard Substances
