- Phone
-
Address
No. 39-502 West, Lvyiju Commercial and Residential Building, Xiuning, Hefei City
Hefei Aibensen Scientific Instrument Co., Ltd
No. 39-502 West, Lvyiju Commercial and Residential Building, Xiuning, Hefei City
Introduction to desktop high-speed centrifuge:
The ABSON desktop high-speed centrifuge combines the advantages of * functionality, high versatility, and simple operability. It adopts the latest control technology, and has reliable quality and good performance. It is widely used in medical laboratories, biochemical and molecular biology research, and routine analysis in industrial laboratories. It is particularly significant in experimental research on genetic genes, protein nucleic acids, and PCR products
Characteristics of desktop high-speed centrifuge:
1: Adopting a reliable Infineon vector sine wave drive system, it can accurately control the speed, time, and relative centrifugal force;
2: Brushless maintenance free variable frequency induction motor, with a speed range of 100-15000rpm and an accuracy of ± 10rpm;
4: High strength host and rotor materials can resist various chemical corrosion, have sealing performance and unlimited high-temperature disinfection function;
5: Stainless steel chamber, sturdy construction, suitable for continuous use, electronic door lock, easy to open cover, automated lock cover ensures experimental safety;
6: Equipped with automatic ID recognition function for multi rotor high-speed models, it makes the use safer and more convenient. The door cover protection, overspeed and imbalance detection system can monitor the centrifugal process in real time, ensuring the safe operation of the instrument. When the operation ends, there is an error or imbalance occurs, the sound signal prompts and the operation stops, and the LED displays the result code;
7: Automatically open the centrifuge cover after centrifugation to prevent sample overheating and facilitate sample retrieval and storage;
8: Equipped with a sealed corner rotor and rotor cover to prevent staff from being contaminated by the sample;
9: Forced ventilation cooling and good air heat exchange technology significantly and effectively reduce the increase in rotor temperature, ensuring that the sample is not damaged. After centrifugation, the centrifuge door cover is automatically opened to prevent sample overheating and facilitate sample retrieval and placement;
10: There is an isolation layer outside the centrifuge chamber that can fully absorb noise, reduce vibration, and provide a sense of tranquility for experimental personnel;
Technical parameters of desktop high-speed centrifuge:
Product Model |
TH-15G |
Maximum capacity [ml] |
50ml(5ml×10) |
Maximum speed [r/min.] |
15000 |
Maximum relative centrifugal force [× g] |
20375 |
Fastest acceleration time [sec] |
16 |
Fastest deceleration time [sec] |
18 |
Speed and centrifugal force step increase regulation |
10rpm/10×g |
time control |
1-99 minutes or 1-99 seconds, with an accuracy of ± 1 second |
Instantaneous centrifugation (flash) |
have |
Speed/Rcf conversion button |
have |
Single button rotary control |
Can quickly make parameter changes |
size(mm) |
280×360×250 |
power supply |
AC230V/50~60Hz |
Noise at maximum speed |
≤56dB(A) |
Desktop high-speed centrifuge rotor parameters:
rotor model |
capacity |
maximum speed |
Relative centrifugal force |
Test tube type |
A-1 angle rotor |
1.5/2.2ml*24 |
15000r/min |
20375G |
PP cone bottom with cover |
A-2 angular rotor |
Capillary hematocrit tube * 24 |
12000r/min |
15455G |
Diameter 1.5mm |
A-3 angle rotor |
5ml*10 |
13500r/min |
12920G |
PP cone bottom with cover |
A-4 angle rotor |
PCR tube tip 0.2 × 8 × 4 |
14800r/min |
16200G |
PP cone bottom with cover |
A-5 angle rotor |
0.5×36 |
13500r/min |
13250G |
PP cone bottom with cover |