| path | model | measurement range | accuracy class | tapered pipe length | Tested fluid state | ||
| Water at 20 ℃ | Air at 20 ℃ | Temperature (°C) | Pressure (Mpa) | ||||
| 3 | LZB-3W(F) LZB-3BW(F) | (0.4~4)ml/min (0.6~6)ml/min (1~10)ml/min (1.6~16)ml/min (2.5~25)ml/min (4~40)ml/min (6~60)ml/min (10~100)ml/min | (6~60)ml/min (10~100)ml/min (16~160)ml/min (25~250)ml/min (40~400)ml/min (60~600)ml/min (0.1~1)L/min (0.16~1.6)L/min |
4 |
100 |
0~60 |
≤0.2 |
| 4 | LZB-4W(F) LZB-4BW(F) | (16~160)ml/min (25~250)ml/min (40~400)ml/min | (0.3~3)L/min (0.6~6)L/min | ||||
| 6 | LZB-6W(F) LZB-6WB(F) | (40~400)ml/min (60~600)ml/min (0.1~1)L/min | (0.7~7)L/min (1~10) L/min (1.5~15) L/min |
2.5 | |||
| 10 | LZB-10W(F) LZB-10BW(F) | (0.1~1)L/min (0.16~1.6)L/min | (3~30) L/min (5~45) L/min | 120 | |||
Note: Please specify the special flow range for ordering
3、 Product Features
1. High sensitivity adjustment
Equipped with regulating valves, supporting fine flow adjustment, suitable for laboratory and precision instrument matching.
2. Corrosion resistant design
The anti-corrosion type adopts 304 stainless steel and fluororubber sealing, which can withstand corrosive media such as strong acids and alkalis.
3. Transparent visual window
Hard glass cone tube design, real-time observation of float position, ensuring clear flow status at a glance.
4. Quick installation and adaptation
Supports hose, thread, and quick interface connections, compatible with multiple pipeline systems.
4、 Application scenarios
1. Environmental monitoring: Trace gas/liquid flow detection in waste gas and wastewater treatment.
2. Medical equipment: Flow calibration of medical instruments such as infusion pumps and ventilators.
3. Laboratory analysis: Fluid control of precision instruments such as chromatography and mass spectrometry.
4.Food and light industry: flow monitoring for beverage filling and trace addition of chemical raw materials.
5、 Installation and maintenance
1. Installation requirements
It must be installed vertically (with the large end of the cone facing upwards) to avoid pipeline vibration or backflow.
Filters need to be installed in the pipeline (if the fluid contains impurities).
2. Operating standards
Open the upstream valve to full open, then slowly adjust the downstream valve to control the flow rate.
Close the upstream valve before closing the downstream valve during shutdown.
3. Maintenance suggestions
Regularly clean the cone tube and float to prevent dirt from affecting accuracy.
If the float is stuck, the pipeline needs to be disassembled and cleaned. It is forbidden to strike the glass tube.