LD-4 floor standing electric centrifuge

NegotiableUpdate on 03/23
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The LD-4 floor standing electric centrifuge is suitable for use in hospital laboratories, clinics, and biochemistry laboratories for qualitative analysis of plasma, serum, urea, and vaccine manufacturing.
Product Details

Floor standing electric centrifuge

1Floor standing electric centrifuge Product Introduction

LD-4The low-speed centrifuge is suitable for qualitative analysis in hospital laboratories, clinics, and biochemistry laboratories, and is used for plasma, serum, urea, and vaccine manufacturing.

IITechnical Specifications

1Power supply:220V 50HZ

2Host speed:4000r/min

3、 Maximum relative centrifugal force:2800g

4Capacity:4×100mlor 12×10ml

5Noise:<75Db(A)

6Weight:49

III Safety Instructions

It is strictly prohibited to operate without a rotating head installed; Before operation, check whether the rotor is corroded or damaged; Do not touch the rotating head while it is running; It is strictly prohibited to operate in a state of unbalanced loading when turning the head.

4Instructions for Use

The worktable of the centrifuge should be flat and sturdy, the workspace should be neat, clean, dry, and well ventilated, and the ambient temperature should be5-32It is appropriate. Turn on the centrifuge and wipe the inner cavity and rotor clean. Place the test tube for weighing *, close the centrifuge cover, adjust the speed knob, and raise it to the desired speed. Before each shutdown, the speed control knob must be placed in the minimum position. Cut off the power supply. Wipe the inner cavity and rotor, and close the centrifuge cover.

5maintenance

Do not place any objects on the centrifuge cover. After each use, be sure to clean and wipe the inner cavity and rotor, cover the centrifuge lid to prevent dust and dirt from entering. If the centrifuge has not been used for a long time before reuse, the centrifuge cover should be opened for a period of time to dry the inner cavity. The carbon brush of the motor is in use3000After hours, it should be replaced promptly to avoid wear and tear on the rectifier. After long-term use, natural grinding and extraction of centrifuges is a normal phenomenon. After one year of use, if there are any malfunctions or difficulties, our company will continue to provide high-quality services and assist in handling them.