- Phone
-
Address
Building 3, Jibang Technology Park, No. 8 Jishan New Road Street, Tianhe District, Guangzhou City
Guangzhou Dongyi Automation Technology Co., Ltd
Building 3, Jibang Technology Park, No. 8 Jishan New Road Street, Tianhe District, Guangzhou City
XSR32FC seriesLCD display flow accumulatorSuitable for applications that require temperature and pressure compensation calculations. 128 × 64 dot matrix LCD screen display, aluminum alloy shell. Simultaneously equipped with current (voltage) flow input channel and pulse input channel. Adapt to various flow transmitters and sensors. Standard configuration includes 2 independent external power supplies, each powered by pressure (temperature) and flow transmitters. Chinese character display mode, convenient setting guidance mode. Simplify the parameter setting process. Record historical data (curves) of instantaneous flow rate, temperature, and pressure, which can be queried. Welcome to consult with all users.
LCD display flow accumulatorProduct Introduction
■ Optional communication interface
Basic specifications
project |
specification |
||
power supply voltage |
ACpower supply |
V0 |
100~240 V AC 50/60 Hz |
AC/DCpower supply |
V1 |
10~24V AC 50/60 Hz;10~24V DC |
|
power consumption |
ACpower supply |
8 VAbelow |
|
AC/DCpower supply |
AC:7 VAfollowing;DC:6Wbelow |
||
Allowable voltage variation range |
The voltage of the power supply90%~110% |
||
insulation resistance |
≥100MΩ(500V DC MEGABenchmark) |
||
insulation strength |
2000V AC (Test conditions:50/60Hz,1Minutes) |
||
anti-interference |
IEC61000-4-2(Electrostatic discharge))Grade III IEC61000-4-4(Electric Fast Transient Pulse Group), Level III IEC61000-4-5(Surge), Level III |
||
Protection level |
IP65(Product front panel protection)(GB/T42-2008) |
||
runtime environment |
ambient temperature |
-10~55℃(Save:-25~65℃) |
|
ambient humidity |
35~85 %R•HNo condensation |
||
Installation location |
Indoor, height<2000m |
||
■ Enter specifications
project |
specification |
|
Measure and control speed |
0.6second |
|
basic error |
±0.2 %F•S |
|
display range |
-99999~99999 |
|
Traffic input signal |
IK |
direct current(4-20)mAThe(0-10)mAThe(0-20) mAAnd pulse input0.1Hz~5kHz |
VK |
DC voltage(0-5)VThe(1-5)VAnd pulse input0.1Hz~5kHz |
|
MK |
millivolt(0~100)mVAnd pulse input0.1Hz~5kHz |
|
Temperature input signal |
R |
Thermal resistance:Pt100TheCU100TheCU50 |
I |
direct current(4-20)mAThe(0-10)mAThe(0-20) mA |
|
E |
Thermocouple:KTheTTheETheS(0~999.9)℃ |
|
Pressure input signal |
I |
direct current(4-20)mAThe(0-10)mAThe(0-20) mA |
V |
DC voltage(0-5)VThe(1-5)V |
|
M |
millivolt(0~100)mV |
|
■ Output specifications
project |
specification |
|
|
external power supply (Pressure channel power supply) |
B1 |
24V±5%,50mAbelow |
B2 |
12V±5%,50mAbelow |
|
|
external power supply (Flow channel power supply) |
B1 |
24V±5%,50mAbelow |
B2 |
12V±5%,50mAbelow |
|
■ Optional specifications
project |
specification |
|
alarm output |
T1~T2 |
1~2Point relay preset output,250V AC/3A, resistive load |
|
Analog output (Resolution:1/3000) |
A1 |
current output(4~20)mAThe(0~10)mAThe(0~20)mA |
A2 |
voltage output(1~5)VThe(0~5)V |
|
A3 |
voltage output(0~10)V |
|
communication interface |
S1 |
RS232Interface,TC ASCIIagreement |
S2 |
RS485Interface,TC ASCIIagreement |
|
M1 |
RS232Interface,Modbus-RTUagreement |
|
M2 |
RS485Interface,Modbus-RTUagreement |
|
USBTransfer interface |
USB |
USBdump |