1. Kubota desktop centrifuge from Japan--S700T
Function Introduction:
1. Speed: 6000rpm; Centrifugal force: 5350xg; Capacity: 3000ml
2. Control system: VFD display screen, microprocessor control using brushless variable frequency motor, rotor with automatic recognition function, no need to input serial number, just put in the rotor to recognize the automatic recognition speed, avoid overspeed, safe and reliable.
3. Alarm display: door cover not open, imbalance, overspeed, motor, frequency conversion circuit abnormality detection function
4. Acceleration/Deceleration: Three options: Fast, Slow, Ultra Slow
5. Speed setting: from 200 to 6000 rpm, increasing by 10 or 100 rpm
6. Centrifugal force setting: from 10 to 5350 xg, increasing by 10 rpm
7. Time setting and display: digital display, with reservation and electronic beeping; 59 minutes and 59 seconds, increasing by 1 second; 99 hours and 59 minutes, increasing by 1 minute; Can operate continuously.
8. High noise: ≤ 60 decibels meets the standard and has an imported medical device registration certificate or filing certificate;
9. Has program memory: ≥ 50 sets, suitable for repeated operations, and can choose ≥ 9 different acceleration and deceleration curves according to sample types and experimental conditions.
10. The centrifugation conditions obtained by calculating the g.sec value function have a customizable step-by-step centrifugation mode;
11. It has a centrifugal force (xg) setting operation function, which can switch between RCF and speed with one click, and display speed/relative centrifugal force alternately;
12. Quality management: There is a circular speed testing window in the center of the centrifuge cover, which can directly measure the speed and comply with GMP standards;
13. Compliant with safety standard IC61010-2-020; The production also has ISO9001 standard quality management system, ISO13485 medical device management system, and EU CE certification.
14. The door lock is an interlocking structure with two locking hooks on the left and right, which is not affected by mechanical impact and adopts an electrical dual protection circuit.
When the sample separation is completed, the door cover can be set to automatically open,
15. Speed setting: from 200 to 6000 rpm, increasing by 10 or 100 rpm
16. There are multiple ringtone prompts to choose from when centrifugation ends
Kubota desktop centrifuge from Japan--S700T
Rotor introduction: Horizontal rotor, no need to replace rotor. Enzyme plate and centrifuge tube rack can be used on the same rotor. The rectangular centrifuge cup has a large capacity (4X750ml), and different test tube racks can be selected: 144x5/7ml, 96X5/10/15ml, 68 × 15ml (TC), 28X50ml (TC), 8X enzyme plate, etc.
Rated voltage and current: 220/230V, 3.7A/3.6A; Power and heat output: 600W, 2.2MJ/H;
Power requirements: single-phase AC220V ± 10%, AC230V ± 10%, 50/60Hz, 8A
At least 144 x5/7ml of test tube should be centrifuged simultaneously; Zui high speed: 8500rpm high centrifugal force: 9690xg large capacity: 3000 mL (4 x 750mL) temperature range: -20 to 40 ° C size (amplitude x depth x height): 500x650x850mm weight: 110kg