E-mail
hbkkgs@yeah.net
-
Phone
18739222263
-
Address
No. 21 Chunlei Road, Shancheng District, Hebi City, Henan Province
Hebi Kaike Analytical Instrument Co., Ltd
hbkkgs@yeah.net
18739222263
No. 21 Chunlei Road, Shancheng District, Hebi City, Henan Province
KZDL-4C fast intelligent sulfur analyzer
Adopting standards:
GB/T214-2007 "Determination of Total Sulfur in Coal", GB/T483-2007 "General Provisions for Coal Analysis Experimental Methods", GB/T387 "Determination of Sulfur Content in Dark Petroleum Products - Tube Furnace Method"
Scope of application:
Suitable for the determination of total sulfur in coal, coke, petroleum and other substances in power, coal mining, metallurgy, chemical, cement geological exploration, scientific research institutions and other departments.
Performance characteristics:
Lenovo computers and printers must be equipped to operate the instrument;
Automatic control of the heating process of the high-temperature electric furnace;
■ Automatic zero calibration of instrument system;
Automatically determine the endpoint of the testing process and exit in a timely manner;
The instrument can automatically maintain up to 100 times of test data, automatically update, and prevent data loss during power outages;
Technical parameters:
Test principle: Coulombic titration method
■ Sample quantity: 1
■ Dimensions: 680mm × 480mm × 430mm
Net weight of the instrument: 40kg
(The following technical parameters are not only available for this instrument, but also for other types of sulfur analyzers in our company.)
Test principle: Coulombic titration method
■ Sulfur resolution: 0.001% (higher than other peers' 0.01%)
■ Sulfur measurement range: 0.1% to 40% (if exceeding the range, please contact special models by phone)
■ Sample weight: 50.0mg (input range 0.1 ㎎~99.9 ㎎) Ultra high sulfur content samples can be weighed less, while ultra-low sulfur content samples can be weighed more for easy analysis of other substances
Test time: 4-8 minutes (automatic determination of titration endpoint, specific time depends on sample type and weight)
Test temperature: 1150 ℃ (coal coke) and 920 ℃ (oil). The temperature control range is 400-1200 ℃, which is convenient for other analyses
Temperature control accuracy ± 2 ℃.
Precision: Complies with GB/T214-2007
Accuracy: Within the allowable error range of the standard sample, and better than the national standard
Power supply: AC220V ± 10% 50Hz
Instrument power consumption: ≤ 3kw. (New design, energy-saving and environmentally friendly.)
Standard configuration: KZDL-4C host, Lenovo brand computer, laser printer (computer sulfur analyzer)
Testing environment requirements and user provided materials
The ambient temperature is 0-40 ℃, and the relative humidity is ≤ 80%. There is no strong vibration, dust, strong electromagnetic interference, or corrosive gas around. The air should be basically free of SO2 gas.
Power supply: 220V, 50Hz, power 3KW.
Worktable: 700mm (width) x 2500mm (length).
Potassium bromide (analytical grade)
Potassium iodide (analytical grade)
Iced acetic acid (analytical grade)
Distilled water or purified water
■ Degreasing cotton (medical)
Color changing silicone gel
■ Standard sample
■ Tungsten trioxide (analytical grade)