K1550Fx hydrogen purity analyzerIt is a model in the HITECH K1550 series, commonly used to detect hydrogen purity in generator sets or hydrogen stations.
K1550Fx hydrogen purity analyzerThe measured concentration is displayed on a large and high-definition LCD screen. In addition, information and prompts that appear when setting and calibrating the instrument using the menu can also be displayed. Both concentration alarms have visual indicators (LED) and power-off conversion contacts. Users can set their functions (high, low, or off) and delay values. Provide 4-20mA output of *.
K1550FxThe display unit can still only be installed in safe areas, while its sensor unit is suitable for installation and use in hazardous areas. If both the display unit and sensor unit need to be installed for use in hazardous environments, they can be optionally installed for secondary metersATEX certificationExplosion proof casing.
For sampling, we can provide various sampling systems as well as the required pumps, filters, and sampling tubes. standard configurationK1550 analyzerThe material of the series' air circuit is polytetrafluoroethylene. If you need a corrosion-resistant and durable stainless steel air circuit, you can choose itK1550-SS。
If oxygen needs to be detected, it can be selectedKG1550Dual sensor gas analyzer, detecting oxygen and another gas.
K1550Fx hydrogen purity analyzertechnical parameters
Display: Dot matrix LCD, capable of displaying two or four lines of characters
Common range: 80-100%90-100%, 95-100%98~100% H2 。
Stability: better than 2% of full scale per month
Accuracy (typical): ± 2% of range
Sample gas flow rate: 100-300ml/min
Sample gas temperature: -10 ℃ to+40 ℃ (non agglomerating)
Sample gas pressure: determined by the exhaust pressure, which must be the nominal atmospheric pressure.
Response speed (typical): (T90) 20s
Sample gas interface: suitable for static sealed compression joints with an outer diameter of 0.25 '(6mm) pipes
Output (signal): programmable 4-20m.
Maximum load: 1000k Ω
Output alarm signal: Two alarms, alarm mode, alarm concentration, and alarm status can all be programmed.
Environmental temperature: -5 to+40 ℃
Power supply: 50 or 60Hz, 110/120V or 220/240V; power consumption 12VA
Installation: Secondary table: disk mounted, with two installation cards; Remote sensor part: wall mounted. Zener safety barrier: track