Welcome Customer !

Membership

Help

Anli 3D (Tianjin) Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Anli 3D (Tianjin) Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    Jinnan Entrepreneurship Building

Contact Now

G1010 G1010R G1010TxX Oxygen Analyzer

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The G1010 G1010R G1010TxX oxygen analyzer in the G1010 series uses primary batteries as the main components and can detect oxygen levels ranging from 100% to 0.1 ppm in various gases. The instrument is controlled by a microprocessor, providing high-quality and diverse functions.

Product Details

Characteristics of oxygen analyzer:

Wide dynamic range

Single point verification

microprocessor control

Programmable alarm and analog output

There are models that can be used in hazardous areas

G1010 G1010R G1010TxX Oxygen AnalyzerAll use primary batteries as the main components, which can detect oxygen levels ranging from 100% to 0.1 ppm in various gases. The instrument is controlled by a microprocessor, providing high-quality and diverse functions. There are several specific models of G1010, such as G1010R, G1010X, G1010Tx, and G1010TxX.

There are also various series of gas analyzers available, including oxygen analyzers G250, G810, Z110, Z1400, Z4010, Z230, Z1030, hydrogen analyzers K1550, K850, K6050, hydrogen oxygen analyzers KG850, KG6050, and chlorine hydrogen analyzer KK650. We also provide standard spare parts for instruments, such as N-type oxygen sensors, L-type oxygen sensors, H-type oxygen sensors, E-type oxygen sensors, 210 type thermal conductivity meters, hydrogen purity sensors, hydrogen in oxygen sensors, display screens, and various circuit boards.

G1010 multi bit automatic shift LCD displays concentration and user adjustable parameters.

G1010 has two alarm channels, which can be programmed by users as high, low, or off. Each alarm provides a set of power-off conversion contacts, which can be set to any concentration value within the instrument range.

When placing an order, the programmable analog output can be set to 0-5V or 4-20mA.

G1010 can provide several different types of sensors, allowing the analyzer to operate well in various application environments. This includes sensors that can be used in the presence of high concentrations of slightly acidic gases such as CO2 and H2S.

Remote sensor type G1010R can also be provided, so that the control/display module can be separated from the sensor by several hundred meters. Depending on the distance between them and the concentration to be detected, sensors can be directly connected to the display module or connected with a built-in two-wire transmitter, such as G1010X and G1010TxX.

Due to the fact that sensors belong to the "simple equipment" category defined by the European standard EN50020, remote sensors can be installed in hazardous areas. However, a suitable Zener safety barrier or isolation barrier must be installed between the sensor component and the control/display module.

G1010 G1010R G1010TxX Oxygen AnalyzerTechnical Specifications:

display

Multi bit LCD - Character Height

stability

Better than 2% of full scale per month

Sample gas flow rate

The optimal flow rate is 100-300ml/min, with a maximum of 1 l/min

sample gas temperature

-5~+40 ℃ (non agglomerating)

Sample gas interface

Inlet and outlet: Static sealed compression joint suitable for pipes with an outer diameter of 0.25 "(6mm)

response speed

T90 varies depending on the sensor and concentration.

At the percentage level, it takes about 3 seconds; at the ppm level, it takes about 20 seconds (assuming the sensor has been blown to the ppm concentration of the measured gas).

analog output

0-5V or 4-20mA

alarm output

Two alarms, which can be set to HIGH, LOW, or OFF respectively

The time delay can be set to 0-10% of the set concentration

Power off conversion contact: The maximum capacity is 250V R.M.S.A.C, 3A, and the maximum power consumption is 60W. It is normally in a powered state.

ambient temperature

0-40 ℃ (connected operation)

-5~+55 ℃ (intermittent operation)

power supply

50/60Hz, 110/120 V or 220/240V or 24V DC

Maximum power consumption 4VA

shell

Disk mounted glass fiber reinforced Noryl with a protection level of IP40. An optional lockable transparent door with a protection level of IP54.