1、 Product Overview
Juchuang Catering Integrated Oil Fume Rapid DetectorJCY-130(S)The model is suitable for measuring the concentration of oil fume, particulate matter, and non methane total hydrocarbons in fixed pollution sources such as chimneys and flues, as well as measuring oil fume parameters such as temperature, dynamic pressure, static pressure, and environmental atmospheric pressure and temperature parameters of flue gas, to evaluate the concentration of organized emissions of oil fume.
2、 Execution standards
JJG 680-2007Verification Regulations for Smoke and Dust Samplers
JJG 518-1998Verification Regulations for Pitot Tubes
GB16157-1996Determination of particulate matter and sampling methods for gaseous pollutants in exhaust from fixed pollution sources
HJ/T48-1999Technical Conditions for Smoke and Dust Samplers
GB18483Emission Standards for Cooking Fumes in the Catering Industry
3、 Main features
1.Easy on-site operation, greater than5Data can be generated in minutes.
2.The electronic flowmeter automatically controls the flow rate without any fluctuations.
3.Using high-performance ultra-low frequency imported diaphragm pump to improve stability, long service life, and ultra-low noise.
4.Measure flow rate and displacement based on pitot tube.
5.Juchuang Catering Integrated Oil Fume Rapid DetectorCan measure smoke temperature, static pressure, and dynamic pressure.
6.Using high-resolution capacitive touch screen, high sensitivity, intuitive interface, and simple operation.
7.Equipped with a Bluetooth printer for fast data output.
8.haveUDisk export function, automatically generates tables for easy data processing.
9.Built-in lithium battery
4、 Technical parameters
Main parameters |
parameter range |
resolution |
accuracy |
sampling flow |
1.0L/min |
0.1L/min |
Better than ±2% |
delay time |
1min~99min |
1min |
Better than ±0.2% |
sampling time |
1min~99min |
1min |
Better than ±0.2% |
Non-Methane Total Hydrocarbons (NMTHC) |
(0~200)mg/m³ |
0.1mg/m³ |
±5% |
particulate matter |
(0~200)mg/m³ |
0.1mg/m³ |
±5% |
cooking fumes |
(0~30)mg/m³ |
0.1mg/m³ |
±5% |
Smoke dynamic pressure |
(0~3500)Pa |
1Pa |
Better than ±2.5% |
Smoke static pressure |
(-35~+35)KPa |
0.01kPa |
Better than ±2.5% |
atmospheric pressure |
(70~130)KPa |
0.1kPa |
Better than ±2.5% |
Smoke temperature |
(-20~220)℃ |
0.5℃ |
Better than ±0.5℃ |
Smoke velocity |
(0~30)m/s |
0.1m/s |
Better than ±5% |
Smoke humidity |
(0~80)% |
1% |
Better than ±2.5% |
Front pressure of flowmeter |
(-35~+0)KPa |
0.01kPa |
Better than ±2.5% |
Temperature before flowmeter |
(-55~+125)℃ |
1.0℃ |
Better than ±2% |
Operating Temperature |
(-20~+80)℃ |
/ |
/ |
Operating Humidity |
(0~95)%RHNo condensation |
/ |
/ |
working power supply |
DC12V 3A |
||
store data |
≥500group |
||
warm-up time |
2minute |
||
Built-in lithium battery |
8.4V 10AH |
||
Continuous working time |
>15h |
||
noise |
<55dB(A) |
||
power consumption |
<12W |
||
Overall dimensions |
220mm×160mm×100mm |
||
Total weight |
about3.2kg |
||
More models, equipment requirements, and discounted quotes