Jiuyin Technology Wall mounted Oxygen Analyzer

NegotiableUpdate on 01/03
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The use of imported fuel cell sensors has the characteristics of long service life, fast response time, high detection accuracy, and long calibration cycle; $n Jiuyin Technology Wall mounted Oxygen Analyzer: Using DT's protective gas path, it effectively protects the sensor and avoids the sensor's lifespan being affected by prolonged exposure to air; Calibration at any point within the range is sufficient, without the need for multiple calibration points, to meet the measurement accuracy of the entire range; Built in temperature compensation function, eliminating the impact of environmental temperature changes on sensor measurement accuracy; Automatic data storage function and the ability to access historical data at any time; The function of switching between Chinese and English menus is intuitive and convenient to operate;
Product Details
Jiuyin Technology Wall mounted Oxygen Analyzer
Technical Specifications:
Measurement principle: fuel cell
Display mode: 320 × 240 dot matrix LCD
Measurement range: 0~10/100/1000ppm, 1.00%, 25.00% O2
Measurement accuracy: 0~1000ppm/1.00%/10.00%/25.00% ≤± 1% FS
0~100ppm≤±2%FS
0~10ppm≤±5%FS
Resolution: 0.1ppm
Repeatability: ≤± 1%
Response time: T90 ≤ 60 seconds
Analog output: 4~20mA.DC (non isolated output, load resistance less than 500 ohms)
0~5V. DC (non isolated output, load resistance greater than 10K ohms)
1 programmable dry contact type passive alarm output, contact Z has a large capacity of 220VAC/2A
Power supply: AC170~264V50/60HZ
Sample gas temperature: 0~50 ℃
Sampling method: suction type or through type
Sample gas flow rate: 600~800ml/min
Working pressure (without pump): 0.05Mpa ≤ inlet gauge pressure ≤ 0.35Mpa, stable pressure atmosphere
Working pressure (with pump): micro positive pressure, micro negative pressure, or normal pressure
Background gases: mixed gases such as He, H2, CO2, N2, and inert gases
L Specification size: 400mm × 300mm × 200mm (H × W × D)
L Service life:>24 months (under normal usage conditions)
Gas interface: NPT1/8 internal thread
Installation method: wall mounted
久尹科技壁挂式氧分析仪
Jiuyin Technology Wall mounted Oxygen Analyzer
Instrument features:
The use of imported fuel cell sensors has the characteristics of long service life, fast response time, high detection accuracy, and long calibration cycle;
Adopting DT's protective air path effectively protects the sensor and avoids the sensor's lifespan being affected by prolonged exposure to air;
Calibration at any point within the measurement range is sufficient, without the need for multiple calibration points, to meet the measurement accuracy of the entire range;
Built in temperature compensation function, eliminating the impact of environmental temperature changes on sensor measurement accuracy;
Automatic data storage function and the ability to access historical data at any time;
The function of switching between Chinese and English menus is intuitive and convenient to operate;
Automatic blowback function (optional), to avoid blockage of the sampling pipeline (especially the filter) caused by dust and other pollutants in the sampling gas;
Built in imported air pump (optional).
Application scenarios:
Widely used for online analysis of oxygen content in industries such as protective gas furnaces for high-temperature sintering furnaces such as magnetic materials and brazing furnaces, protective gas furnaces for electronic semiconductors, and glass process requirements.
Ordering Notice (Please specify when placing an order)
Instrument measurement range
Measure whether the medium contains acidic gases (such as CO2, etc.)
Tested gas pressure: positive pressure, slight pressure, or negative pressure
Main components, impurities, and sulfides of the tested gas