- Phone
-
Address
Building 1, 6400 Yinggang East Road, Qingpu District, Shanghai
Tianchou (Shanghai) Automation Equipment Co., Ltd
Building 1, 6400 Yinggang East Road, Qingpu District, Shanghai
Japanese CKD air solenoid valve AB41-02-3-02G-DC24
Electromagnetic valve for dry air
Direct acting 2-3 way solenoid valve for dry air (multi-purpose fluid valve)
Model AB, GAB, AG, GAG-Z
High durability direct acting solenoid valve suitable for dry air from atmospheric dew point -60 ℃ to inert gases such as nitrogen.
High durability
Based on the rectification of coils and anti wear measures for sliding parts, high durability can be achieved even for dry air and inert gases.
The valve body material (brass, stainless steel) and seal material (nitrile rubber, fluororubber, EPDM) can be selected.
【 Compact 】
Suitable for integrated valves, it can achieve space saving in piping.
modelnameSwitch categoriesPipe diameterremark
AB31-Z2-way single valveNC typeRc1/8, 1/4
AB41-Z2-way single valveNC typeRc1/4, 3/8
GAB-Zintegrated valve--
AG3※-Z3-way single valveRc1/8, 1/4
AG4※-Z3-way single valveRc1/4, 3/8
GAG-Zintegrated valve
Japanese CKD air solenoid valve AB41-02-3-02G-DC24
Regarding the use of fluids
Quality standards for dry air applicable to multi-purpose fluid valves (Z series) for dry air
Accurate, atmospheric dew point above -60 ℃, oil removal rate: 0.01mg/m3
Below.
2 cannot be used for vacuum maintenance. When used for vacuum maintenance, please contact our sales representative
Negotiation.
Regarding continuous power on
When continuously energizing (using) a three-way valve through NO side pressurization, please use the NO pressurization type.
In addition, please use fluororubber seals for continuous power on of universal and NC pressurized types.
Regarding leakage current from other control components
When driving solenoid valves through PLC or other means, please confirm that the output leakage current of the PLC is present in each machine
Within the specification range of the species. Otherwise, it may lead to misoperation.
1. Manual operation method
When using a manual device, please follow the following instructions.
<NC (open when powered on) type>
Opening operation: Insert a screwdriver into the groove of manual shaft one and turn it to the right or left
After rotating about 120 °, the moving iron core rises and becomes open (when using a three-way valve)
The NC valve side is open, and the NO valve side is closed.
Even if the drive is removed, it remains open.
Please make sure to return to the original position after use.
Closing operation: Rotate the manual shaft from the open position, and after the groove returns to the vertical position,
The moving iron core descends to a closed state (when the three-way valve is closed, the NC side valve seat is closed,
The NO side valve seat is open. (Refer to the following figure)