JJH-500TL nuclear air purification car is usually used in nuclear powernuclear medicineOn site decommissioning and dismantling of nuclear facilities, radioactive decontamination, nuclear equipment maintenance, waste sorting, etc., can ensure environmental cleanliness and prevent internal radiation hazards; Used to remove gaseous radioactive aerosols and radioactive iodine from the air in the nuclear air isolation room (SAS), achieving the purpose of purifying the air and ensuring the safety of operators.

Equipment characteristics and progressiveness:
This car adopts a newly designed top tightening device, which is more convenient for fixing and completely sealing the filtering device.
The high-efficiency filter used in this car adopts the current domestic new technology polymer material filter material, which is conducive to enhancing the filtration effect on nuclear air.
This car adopts a high-quality steel shell (spray painted), which is beneficial for extending the service life, reducing maintenance costs, and easy to clean and remove dirt.
This car has undergone structural optimization design to reduce the overall weight, facilitate movement and transportation, and replace high-efficiency filtersIodine adsorber.
The small car has added a storage cabinet at the bottom of the car, which can store air ducts, cables, tools, etc. with the car, making the appearance beautiful and tidy.
The sealed box part of this car adopts frame reinforced support components inside the box, making the structure of the sealed box more solid and reliable.
Product comes with supporting documents:
1) JJH-500TL Maintenance and Use Manual for Nuclear Air Purification Vehicle (including equipment vulnerable parts, spare parts list, and maintenance drawings).
2) JJH500 Nuclear Air Purification Vehicle Test Regulations.
3) JJH500 Nuclear Air Purification Car Manufacturing Quality Plan.
4) JJH500 nuclear air purification vehicle efficiency test report (one copy per vehicle).
5) JJH500 Nuclear Air Purification Vehicle Training Manual.
6) JJH500 nuclear air purification trolley supporting air duct documents (including manufacturer's certification and inspection report, etc.).
7) JJH500 nuclear air purification car supporting fan, differential pressure gauge related documents (including manufacturer certification, user manual, inspection report, etc.).
8) JJH500 nuclear air purification car certificate and warranty card (one copy per car).
9) Production completion report of JJH500 nuclear air purification car equipment.
10) Quality Assurance Documents (Quality Assurance and Quality Control).
11) Quality assurance documents for purchased components of the equipment.
12) Manufacturer profile, business license, and quality management system certification certificate (in both Chinese and English).
Main technical indicators:
JJH500 nuclear air purification car:
Rated air volume: 500 cubic meters per hour
Initial resistance: ≤ 250Pa (under rated air volume)
Dimensions: 630mm × 450mm × 900mm
Weight: ≤ 55Kg
The filtration efficiency of the whole machine is ≥ 99.99% (DOP method, sodium flame method)
Electrical configuration: 220V AC, 370W
Function: Integrated horizontal movement, vertical structure
Supporting equipment (consumables): GG/ZA high-efficiency air filter
Instructions:
(1) Equipment assembly
Installation of high-efficiency filters and iodine adsorbers. During installation, the airflow direction of the car should be consistent with the direction indicated on the high-efficiency filter and iodine adsorber. The sealing gasket should be evenly compressed, and the compression amount should not be too large, preferably controlled at 40% -60%. If the sealing gasket is found to be damaged or lose elasticity, it should be replaced.
Installation of air ducts. When installing the air duct, a stainless steel hose clamp should be used to tightly connect the air duct to the air inlet of the trolley to ensure good sealing.
Installation of sealed doors. When installing the sealed door, use a fixed handwheel to tighten the seal.
(2) Use
The safe operation and safety of JJH500 nuclear air purification trolley should be regularly inspected and tested on site after a period of use.
The relative humidity of the airflow should be less than 50%, otherwise a drying device should be installed.
To ensure the normal use of the car, daily monitoring of the pressure difference between the high-efficiency filter and iodine adsorber should be carried out. If the display of the differential pressure gauge exceeds twice the initial resistance, it needs to be replaced, or if the radiation dose rate exceeds 250uSv/h, the iodine adsorber needs to be replaced.
(3) Disassemble the high-efficiency filter
Put on latex gloves, loosen the top tightening device, and remove the high-efficiency filter from the rack.
Seal the extracted high-efficiency filter with a plastic bag.