The JJH-1200TW nuclear air purification+iodine adsorption vehicle is commonly used in nuclear facility decommissioning and dismantling, radioactive decontamination, nuclear equipment maintenance, waste sorting, and other sites to ensure environmental cleanliness and prevent internal radiation hazards; Used to remove gaseous radioactive aerosols and radioactive iodine from the air in the nuclear air isolation room (SAS), achieving the purpose of purifying the air and ensuring the safety of operators.

Equipment characteristics and progressiveness
This car adopts a newly designed top tightening device, which is more convenient for fixing and completely sealing the filtering device.
The high-efficiency filter used in this car adopts the current domestic new technology polymer material filter material, which is conducive to enhancing the filtration effect on nuclear air.
This car adopts a high-quality steel shell (spray painted), which is beneficial for extending the service life, reducing maintenance costs, and easy to clean and remove dirt.
This car has undergone structural optimization design to reduce the overall weight, facilitate movement and transportation, and replace high-efficiency filtersIodine adsorber.
This small car has added a storage cabinet at the bottom of the car, which can store air ducts, cables, tools, etc. with the car, making the appearance beautiful and tidy.
The sealed box part of this car adopts frame reinforced support components inside the box, making the structure of the sealed box more solid and reliable.
Technical Indicators:
Rated air volume: 1200 cubic meters per hour
Initial resistance: ≤ 120Pa+380Pa (at rated airflow)
Dimensions: (1) Vehicle body 1500mm × 1500mm × 800mm
Weight: ≤ 250Kg
The filtration efficiency of the whole machine is ≥ 99.9%
Electrical configuration: 380V AC, 2.2KW
Function: Integrated climbing and movement, horizontal structure
Supporting product: RIZ-2000 iodine adsorber VH66-H13 high-efficiency filter
Enclosing Documents
1) JJH-1200TW Nuclear Air Purification+Iodine Adsorption Car Maintenance and Use Manual (including equipment vulnerable parts, spare parts list, and maintenance drawings).
2) JJH1200 Nuclear Air Purification+Iodine Adsorption Trolley Test Procedure.
3) JJH1200 Nuclear Air Purification+Iodine Adsorption Car Manufacturing Quality Plan.
4) JJH1200 nuclear air purification+iodine adsorption small car efficiency test report (one copy per car).
5) JJH1200 Nuclear Air Purification+Iodine Adsorption Car Training Manual.
6) JJH1200 nuclear air purification+iodine adsorption trolley supporting air duct documents (including manufacturer certification and inspection reports, etc.).
7) JJH1200 nuclear air purification+iodine adsorption trolley supporting fan, pressure difference gauge related documents (including manufacturer's certification, user manual, inspection report, etc.).
8) JJH1200 nuclear air purification+iodine adsorption car qualification certificate and warranty card (one copy per car).
9) Production completion report of nuclear air purification vehicle/nuclear air purification+iodine adsorption vehicle equipment.
10) Manufacturer's quality assurance documents (quality assurance and quality control).
11) Quality assurance documents for purchased components of the equipment.
12) Introduction to the manufacturing plant, business license, and quality management system certification certificate (in both Chinese and English).
Instructions for use
(1) Equipment assembly
Installation of high-efficiency filters and iodine adsorbers. During installation, the airflow direction of the car should be consistent with the direction indicated on the high-efficiency filter and iodine adsorber. The sealing gasket should be evenly compressed, and the compression amount should not be too large, preferably controlled at 40% -60%. If the sealing gasket is found to be damaged or lose elasticity, it should be replaced.
Installation of air ducts. When installing the air duct, a stainless steel hose clamp should be used to tightly connect the air duct to the air inlet of the trolley to ensure good sealing.
Installation of sealed doors. When installing the sealed door, use a fixed handwheel to tighten the seal.
(2) Use
In order to ensure the safe operation of the JJH1200 nuclear air purification+iodine adsorption trolley, regular on-site inspection tests should be conducted after the trolley has been in use for a period of time.
The relative humidity of the airflow should be less than 50%, otherwise a drying device should be installed.
To ensure the normal use of the car, daily monitoring of the pressure difference between the high-efficiency filter and iodine adsorber should be carried out. If the display of the differential pressure gauge exceeds twice the initial resistance, it needs to be replaced, or if the radiation dose rate exceeds 250uSv/h, the iodine adsorber needs to be replaced.
(3) Disassemble the high-efficiency filter and iodine adsorber
Put on latex gloves, loosen the top tightening device, and remove the high-efficiency filter and iodine adsorber from the rack.
Seal the extracted high-efficiency filter and iodine adsorber with plastic bags.