JH5005A ion air curtain can generate a large amount of airflow with positive and negative charges, which can neutralize the charges carried on objects. When the surface charge of an object is negative, it absorbs positive charges from the airflow. When the surface charge of an object is positive, it absorbs negative charges from the airflow, thereby neutralizing static electricity on the surface of the object and achieving the goal of eliminating static electricity. High speed compressed air can also blow away stubborn dust deposits on objects.
Ionizing device: Under the action of high voltage and low current generated by the high-voltage generator, the ionizing device forms a stable high-voltage electric field, ionizes the air to form ions, which are carried out by the high-voltage airflow to reach the surface of the object, achieving the purpose of neutralizing static electricity and dust removal.
1. Neutralize static electricity quickly.
2. Ionic airflow covers a large area.
3. The wind speed regulation range is wide (air conditioning valves need to be installed).
4. The ion air curtain has good grounding protection.
Input voltage |
220V/50Hz or 110V/60Hz |
Output voltage |
AC7.0KV(JH1103A) |
Power |
20W |
Environmental operating temperature |
-10℃~+50℃ |
Length of high-voltage power lines |
3M |
Stick long |
Customized according to customer requirements |
Airflow velocity |
3~10m/S |
Compressed air pressure |
0.3Mpa~0.8Mpa |
Test results:
Tester distance |
centerline |
100mm |
0.4s |
200mm |
0.5s |
300mm |
0.6s |
*The static elimination time complies with ESD standards, and is measured from a test voltage of 5000V to 500V.
*The results of the ME268A electrostatic comprehensive tester used for testing shall prevail.
*The test is based on IEC-6140-5-1 A · 6.
*The test data may vary due to changes in surrounding temperature and humidity.