Introduce the outline drawing of Vickers pressure switch
Range: -100Kpa to 200MPa;
Power supply voltage: 12~35V DC (24V DC calibration voltage)/AC 220V AC power supply
When the pressure inside the system is higher or lower than the rated safety pressure, the disc inside the sensor instantly moves, and the switch joint is connected or disconnected by the connecting guide rod. When the pressure drops or rises to the rated recovery value, the disc instantly resets, and the switch automatically resets. Or simply put, when the measured pressure exceeds the rated value, the free end of the elastic element shifts, directly or after comparison, pushing the switch element to change the on/off state of the switch element, achieving the purpose of controlling the measured pressure. The elastic components used in pressure switches include single coil spring tubes, diaphragms, bellows, and corrugated tubes.
Output relay capacity: 380V 3A, 220V 5A, 24V DC 5A, etc
Accuracy: better than various parameters such as 0.0.5% FS and 1% FS
Function activation: When the pressure exceeds (upper limit+0.1MPa), the relay is disconnected and the screen alarm displays "E-2". When the pressure falls below (upper limit+0.1MPa) again, the alarm is cancelled and the controller resumes operation.
Setting range: Full range range range can be set
Sampling rate: 10 times/second (can be customized according to customer requirements).
Interface thread: M20 * 1.5, G1/4, G1/2, 1/4NPT
Mechanical pressure switch, caused by pure mechanical deformation resulting in micro switch action. When the pressure increases, it acts on different sensing pressure components (diaphragm, bellows, piston) to deform and move upwards. Through mechanical structures such as railing springs, the top micro switch is finally activated to output electrical signals. The setting method of UE pressure switch can be divided into continuous displacement type and force balance type based on functional principles.

DG4V-3-2AL-M-U-H7-60
DG4V-3-OC-M-U-H7-60
Blade pump 45V42A-1A-22-R
Vickers CG5V-6GW-EMUH7-11
Vickers CG2V-6GW-10
Vickers DG3V-8-2C-10-EN521
Vickers DG4V-3-35A-VM-S7-U-H7-60
DG4V-5-2AJ-VM-U-P7-22
DGMX2-5-PP-BW-B-40 Vickers
Balance valve CBV1-10-S-1S4G-A-30
YYO20240306-226
DGMX2-5-PP-BW-B-30
Overflow valve DG4V-3-0B-M-UH7-60
Introduce the outline drawing of Vickers pressure switch