Scope of application: Salt water spray testing machine is designed for surface treatment of various materials, including coating, electroplating, organic and inorganic film, anodic treatment, antirust oil and other anti-corrosion treatments, and then test their corrosion resistance to establish the quality of products.

Model and Name:QBYW-90Salt water spray tester
one、experimental space:900×600×500mm(W*D*H)mm
twoOuter box size:1400×800×1180mm(W*D*H)mm
IIIpower supply:220Vsingle-phase2KW 50HZ
4All materials:
1. |
The laboratory uses imported PVC polyethylene board with a thickness of 5mm and a durable temperature of 80 ℃. |
2. |
The laboratory sealing cover is made of imported European acrylic board with a thickness of 4.5mm. |
3. |
The test drug replenishment bottle adopts a hidden water level gauge, which is easy to clean and not easy to break. |
4. |
The pressure air tank is made of SUS # 304 stainless steel, which is resistant to high pressure and has excellent insulation effect |
5. |
The laboratory basket frame adopts a flat dividing frame, which can adjust the angle freely. It is consistent in terms of falling and receiving fog on all sides, and has a large number of test pieces placed. |
5according toCNS. JIS. ASTMSpecification, adjustable constant temperature control:
1. |
Salt water spray test: |
NSS (neutral), ACSS (acidic), AASS (acetate salt spray test) |
2. |
Laboratory: Pressure air tank: |
35℃±1℃ 47℃±1℃ |
3. |
Corrosion resistance test: |
CASS (Copper Acetate) |
4. |
test room: Pressure air tank: |
50℃±1℃ 63℃±1℃ |
6、 Air supply system: The air pressure is1kg/cmTwo stage adjustment
Adjusted to 2kg/cm ² imported air filter with drainage function;
The second adjustment is1kg/cm ² pressure.
7Spray mode:
1. |
The Bernoulli principle is used to extract salt water and then atomize it uniformly, which can prevent crystallization and ensure the standard of continuous testing. |
2. |
Nozzle: Made of special glass nozzle, with adjustable spray volume. |
3. |
Spray volume adjustment 1-2mI (mI/80cm ²/h) (16 hour average) |
4. |
Spray mode: continuous |
5. |
Using direct heating method, the heating speed is fast and the standby time is reduced. When the temperature reaches ON/OFF, the temperature switchesLow power consumption. (The heating tube is made of a highly corrosion-resistant heating system: titanium tube). |
8、 Safety protection device:
(A) When the water level is low, the power supply device is automatically cut off.
(B) When the temperature exceeds the limit, the power supply device of the heater will be automatically cut off.
(C) Equipped with safety warning light device.
(D)The warning light automatically alerts at the end.
9、 Standard configuration
1. |
Storage rack |
1 set (6 upper row 0-shaped bars and 6 lower row V-shaped frames)6branch) |
2. |
50ml measuring cylinder |
1 unit |
3. |
temperature indicator |
2 groups |
4. |
Collecting cups |
2 pieces |
5. |
Glass nozzle |
1 unit (regularly cleaned) |
6. |
Salt water filter |
1 unit (regularly cleaned) |
7. |
Spray tower |
1 set |
8. |
Mist removal system |
1 group |
10、 Random attachments
1. |
Sodium chloride (NaCl) 500g |
2 bottles |
2. |
Operation manual and warranty card |
1 copy |
3. |
5L plastic measuring cup |
1 unit
|