KC-4ATintelligentParticle strengthdeterminationceremony
I. Overview
KC-4AT-1000NtypeintelligentThe particle strength meter adopts advanced measurement and control technology, which can automatically complete force application, measurement display, and maximize the strength valueAnd the average valueThe locking and resetting operations of this instrument are highly automated and have a wide measurement range. It has the advantages of small size, direct reading of measurement values, high accuracy, and easy use, making it an ideal new instrument for particle strength determination.
2、 Main technical indicators:
1.Power supply voltageAC220V±10% 40W
2.Ambient temperature0℃~40℃
3.Relative humidity: ≤85%
4.Particle diameter: ≤35mm
5.Measurement range:5N~1000N
6.Resolution:0.1N
7.Measurement accuracy: ≤0.5%FS
8.External dimensions:225mm×325mm×330mm
9.Weight:25㎏
2.Open the test doors and windows, place the sample in the center of the sample tray, and close the test doors and windows.Conventional mode (single shot),Press the start button, and the linear motor will automatically apply force. When it comes into contact with the sample, the display will output real-time data. When the sample is broken, the buzzer will soundyowlAs a reminder(When the sensor is reset and no longer subjected to force, the buzzer stops beeping)The maximum value of the applied force (strength value) is locked, and the linear motor runs in reverse untilreturn to positionStatus stopped,You can also click on the 'Pause' button in the interface/The reset button pauses and returns to its original position to save pressing time and shorten detection time.
3.When continuing the experiment, remove any residue from the sample,If the interface is not paused/Reset to zero,canClick on the 'Pause' button in the interface/Reset to zeroClear the previous result values with the keyIf the interface has been paused/Clear to zero, can be directly resetClick the 'Start' button on the interface to directly test the data,Repeat the above steps.
4.When the sample strength is too highWhen exceeding the range, displaying numerical valuesfor999.9NWhen leaving the factory, the alarm value is set at950NinsideTo prevent sensor overload and damage)The instrument buzzer sounds, indicating an over range alarm, and the linear motor automatically runs in reverse untilreturnPosition status, thisResult valueThe locked value is invalid.