Intelligent mattress heart rate and breathing simulator
Key Features:Heart rate and breathing simulator, also known as intelligent mattress tester, intelligent pillow simulator, sleep simulation tester.
Applicable to:Suitable for intelligent sleep mattresses, pillows, and other sensing solutions such as ceramic piezoelectric sensing, millimeter wave radar, and gyroscopesCan be used for pillows, sleep respiratory monitors, sleep recorders, physical sign monitors, wearable heart rate monitors, etcHeart rate and respirationSimulation testing.
Applicable locations:Smart mattresses, smart pillows, sleep breathing related enterprises, medical device testing and registration institutions, medical metrology calibration units, and high-endSchool research, teaching, and training.
Intelligent mattress heart rate and breathing simulator
Technical Specifications
parameter name |
Heart rate respiratory simulator(LFT-B/A)Technical specifications |
||||
measurement range |
step size |
margin of error |
widthDegree level |
||
heart rate |
40-240 times/min |
1 time/min |
±1 time/min |
0~Level 5 |
|
breathe |
5-100 times/min |
1 time/min |
±1 time/min |
0~Level 5 |
|
Mode Settings |
singleHeart rate mode |
Only activate heart rate mode |
|||
singlebreathing pattern |
Only activate breathing mode |
||||
heart rate+Breathingmixpattern |
Heart rate and respiration are activated simultaneously |
||||
output signal |
Low frequency vibration and expansion signals,simulationHuman heart rate and respiratory signals |
||||
LFT-B |
Equipped with an independent silicone mold, the internal filling material isSilicone |
||||
LFT-A |
The mold and the host are integrated, and the contact surface is made of rubber |
||||
IIIConfiguration List
serial number |
Material Name |
quantity |
explanation |
1 |
host |
1 unit |
Nothing |
2 |
Silicone mold body |
1 unit |
Nothing |
3 |
connecting wire |
1 item |
Nothing |
4 |
3-core power cord |
1 item |
Nothing |
5 |
Instruction Manual |
1 point |
electronic version |
6 |
Measurement Calibration Certificate |
1 copy |
printed version |
7 |
Certificate of Conformity&Warranty Card |
1 copy |
printed version |
Operation steps introduction:
1Connect the host controller and silicone mold through the manufacturer's standard data cable;
2Connect the host controller to the AC power supply and turn it on;
3Place the silicone mold on the tested instrument, paying attention to aligning the center of the silicone mold with the sensor position;
4Click the start button on the main interface to see the waveform moving, indicating signal output, and observe the numerical reading on the tested instrument;
5Adjust the range and amplitude of heart rate or respiratory rate values, and directly touch and click on the corresponding area of the interface to make relevant settings;
6If only measuring single heart rate mode, set the breathing amplitude to 0If only one breath is measured, set the ECG amplitude to 0.
1. Stick the adhesive tape or strip used by the device on the testing window, paying attention to placement
Central position, diagram 2 Just a reference;
2. Operating the shuttle knob: Rotate the shuttle to select the operating button;
3. LCD screen: displays breathing amplitude and breathing rate;
4. Power switch: power on and off;
5. Power socket: external connection 220V/50Hz power