Acoustic wave detector calibration device
1、 Product Introduction:
The calibration device of the sound wave detector is based on《Design and manufacture of JJG 990-2004 Ultrasonic Testing Instrument Verification Regulations, used for the verification and calibration of ultrasonic testing instruments, concrete ultrasonic testing instruments, foundation pile CT imaging testing instruments, and non-metallic ultrasonic testing instruments. The device consists of a signal generator, attenuator, sound path adjustment device, load resistor, AC voltmeter, oscilloscope, etc. It can complete the calibration and verification of sound time measurement (sound signal, electrical signal), amplitude measurement level linearity, transmission voltage stability, frequency range of the receiving system, channel isolation, and other items. Optional soundproof water tank, measuring hydrophone, measuring amplifier, etc. can complete the amplitude measurement range, resonant frequency of the transmitting transducer, and other calibration items.
2、 Technical indicators
signal generator |
attenuator |
||
parameter name |
Technical specifications |
parameter name |
Technical specifications |
frequency range |
(0.01~25)MHz |
frequency range |
(0~30 )MHz |
Frequency accuracy |
5×10-6 |
Attenuation range |
(0~71 )dB |
Frequency stability |
5×10-6 |
regulation in steps |
0.1dB,1dB,10dB |
distortion |
0.5% |
error |
±0.2dB/10dB |
Voltage amplitude error |
±1% |
average power |
2W |
Voltage amplitude |
(0.01~20)Vpp |
Peak power |
100W (5 μ s pulse width, 2% load cycle) |
Output level frequency response |
±0.5dB |
Standing Wave Ratio |
1.1 |
parameter name |
Technical specifications |
parameter name |
Technical specifications |
scope |
0~500mm |
frequency range |
10Hz~300kHz |
resolution |
0.01mm |
voltage range |
100mV~100V |
Precision |
0.015mm |
Voltage indication error |
±1.0% |
display |
Digital Display |
input impedance |
1MΩ |
☆ Configuration List of Acoustic Detector Calibration Device
name |
quantity |
Acoustic wave detector calibration device host |
1 |
Sound path adjustment device |
1 |
Digital voltmeter (optional) |
1 |
Oscilloscope (optional) |
1 |
Temperature gauge (optional) |
1 |
Vernier caliper (optional) |
1 |
power cord |
1 |
test line |
3 |
packing box |
1 |
instruction manual |
1 |
Calibration Certificate |
1 |
Acoustic wave detector calibration device