Welcome Customer !

Membership

Help

Shanghai Lifutong Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Acoustic wave detector calibration device

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

High tech products such as ultrasonic flaw detector calibration device, magnetic particle flaw detector calibration device, eddy current flaw detector calibration device, acoustic wave detector calibration device, pH meter calibration device, conductivity meter calibration standard, meter calibration device, and quantitative packaging commodity net content inspection equipment

Product Details

Acoustic wave detector calibration device


1、 Product Introduction:

The calibration device of the sound wave detector is based on《Design and manufacture of JJG 990-2004 Ultrasonic Testing Instrument Verification Regulations, used for the verification and calibration of ultrasonic testing instruments, concrete ultrasonic testing instruments, foundation pile CT imaging testing instruments, and non-metallic ultrasonic testing instruments. The device consists of a signal generator, attenuator, sound path adjustment device, load resistor, AC voltmeter, oscilloscope, etc. It can complete the calibration and verification of sound time measurement (sound signal, electrical signal), amplitude measurement level linearity, transmission voltage stability, frequency range of the receiving system, channel isolation, and other items. Optional soundproof water tank, measuring hydrophone, measuring amplifier, etc. can complete the amplitude measurement range, resonant frequency of the transmitting transducer, and other calibration items.

2、 Technical indicators

signal generator

attenuator

parameter name

Technical specifications

parameter name

Technical specifications

frequency range

(0.01~25)MHz

frequency range

(0~30 )MHz

Frequency accuracy

5×10-6

Attenuation range

(0~71 )dB

Frequency stability

5×10-6

regulation in steps

0.1dB,1dB,10dB

distortion

0.5%

error

±0.2dB/10dB

Voltage amplitude error

±1%

average power

2W

Voltage amplitude

(0.01~20)Vpp

Peak power

100W (5 μ s pulse width, 2% load cycle)

Output level frequency response

±0.5dB

Standing Wave Ratio

1.1

parameter name

Technical specifications

parameter name

Technical specifications

scope

0~500mm

frequency range

10Hz~300kHz

resolution

0.01mm

voltage range

100mV~100V

Precision

0.015mm

Voltage indication error

±1.0%

display

Digital Display

input impedance

1MΩ

☆ Configuration List of Acoustic Detector Calibration Device

name

quantity

Acoustic wave detector calibration device host
(Signal generator, attenuator, load, signal processing unit)

1

Sound path adjustment device

1

Digital voltmeter (optional)

1

Oscilloscope (optional)

1

Temperature gauge (optional)

1

Vernier caliper (optional)

1

power cord

1

test line

3

packing box

1

instruction manual

1

Calibration Certificate

1

Acoustic wave detector calibration device

声波检测仪检定装置