Welcome Customer !

Membership

Help

Jinhu Ouwang Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Jinhu Ouwang Technology Co., Ltd

  • E-mail

    jhowkj@163.com

  • Phone

    15952326780

  • Address

    No. 48-11 Jinhu Road, Jinhu County, Jiangsu Province

Contact Now

Integrated industrial concentration/density transmitter

NegotiableUpdate on 07/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Overview of integrated industrial concentration/density transmitter/densitometer intelligent concentration and density transmitter. Intelligent concentration/density transmitter is a device used for continuous online measurement of liquid concentration and density, which can be directly used in industrial production processes

Product Details


Integrated industrial concentration/density transmitter/density meter


Overview of Intelligent Concentration and Density Transmitters
Intelligent concentration/density transmitter is a device used for continuous online measurement of liquid concentration and density, which can be directly used in industrial production processes. Its advanced technology comes from differential pressure transmitters based on capacitive sensors and pressure relays applied in the production process. Its precision software can accurately measure density.
According to different industrial processes, density can be represented in the following ways: Brix degree, Gay Lussac degree, Baum degree, Plato degree, concentration, etc.
This transmitter is a two-wire transmitter, mainly used for industrial process control, and can generate corresponding 4-20mA signals according to the concentration and density. Remote calibration and monitoring can be achieved through digital communication.
It can be installed outdoors, in pressure tanks, or through external sampling devices. The clean type transmitter uses TriClamp as the interface for easy disassembly and assembly. Its liquid contact surface is standard 32Ra. All models comply with 3A standards, with no cracks on the surface and good sealing for food and beverages. 3A is a recognized hygiene standard for the food processing industry, pharmaceutical industry, and beverage industry.
MAT3011 (Industrial Type) General Purpose
MAT301S (sanitary type) is used in food and other processes that require cleaning interfaces
Both types of transmitters have two installation methods: top mounted in a straight line and side mounted in a curved line

Technical characteristics of intelligent concentration and density transmitters
Accuracy: ± 0.0004g/cm3 (± 0.1 Brix) On site calibration: No calibration parameters required
Range: 0.5 g/cm3 to 5 g/cm3, no laboratory calibration required
No moving parts, no process interruption
The interface meets industrial and hygiene standards, simplifies maintenance, and does not require regular cleaning
Diaphragm material: 316L stainless steel or Hastelloy C remote diagnosis
Maximum static pressure: 17 kgf/cm3 digital communication (HART protocol)
The transmitter housing is made of aluminum or 316 stainless steel

Application of intelligent concentration and density transmitters
Sugar industry and brewing industry
Brix measurement of unfermented grape juice, mixtures, syrups, honey, pastes, juices, etc; Measure the Baume concentration, alcohol concentration, and contact surface of the mixed liquid in lime water.
Dairy industry
Cheese, condensed milk, cream and cheese, etc.
Juice industry
Oranges, oranges, lemons, passion fruit, grapes, etc.
oil refinery
Lubricants, fragrances, fuels, vegetable oils, etc.
food processing
Tomato juice, tomato sauce, jelly and jam, candy, juice, honey, etc.
Pulp and Paper Industry
Beverage processing
Beer, soft drinks, fruit wine, coffee, and their by-products.
chemical plant
Urea, acids, potassium hydroxide, toluene, etc.
Petroleum By-Products

Parameters of intelligent concentration and density transmitters
temperature range
Environmental temperature: -40 ℃~85 ℃ (-40 ℃~185oF)
Process temperature: 0 ℃~120 ℃ (32~248oF)
Storage temperature: -40 ℃~100 ℃ (-40 ℃~212oF)
Start Time
Start within 5 seconds after power on
Static pressure range
1.7Mpa(17Kgf/cm2)
Humidity range
0-100% RH relative humidity
damping adjustment
0-32 seconds (excluding sensor intrinsic response time of 0.2 seconds) (digital communication)

performance index
Reference conditions: The range starts from zero, temperature is 25 ℃, atmospheric pressure, 24V power supply, silicone oil, isolation diaphragm is made of 316L stainless steel, and the data setting range is the same as the upper and lower limits of the range.
range accuracy Environmental temperature effect (every 10 ℃) Stability (3 months) Zero point static pressure (2)
(Every 1kgf/cm2)
1
2
3
±0.0004g/cm3 (±0.1°Bx)
±0.0007g/cm3
±0.0016g/cm3
0.003kg/cm3
0.013kg/cm3
0.041kg/cm3
0.021kg/cm3
0.083kg/cm3
0.521kg/cm3
0.001kg/cm3
0.004kg/cm3
0.007kg/cm3




Industrial Type Selection Table
Model MAT301 Industrial density/concentration transmitter
code range
A
B
C
0,5 a 1.25 g/cm3
1.0 a 2.5 g/cm3
2.0 a 5.0 g/cm3
code DIAPHRAGM MATERIAL
H
I
Z
Hastelloy C276
316l stainless steel
other
code Filling degree
A
S
G
T
Z
DC 200/350
DC 200/20
glycerin and water
Syltherm 800
other
code display
N
M
Without display
With display
code electrical interface
O
A
B
Z
1/2-14NPT
M20×1/2
Pg13,5 DIN
other
code install
1
2
top
side
code Process interface size, pressure ratio, and standards
6
6
6
9
Z
1
2
3
C
Z
3″150# ANSI B-16.5
3″300# ANSI B-16.5
3″600# ANSI B-16.5
DN 80 PN25/40 2526-FORM D
other
code Other options
HI
ZZ
316 stainless steel shell
Other special materials
Sanitary Type Selection Table
Model KX301 Sanitary density/concentration transmitter
code range
A
B
C
0,5 a 1.25 g/cm3
1.0 a 2.5 g/cm3
2.0 a 5.0 g/cm3
code DIAPHRAGM MATERIAL
H
I
Z
Hastelloy C276
316l stainless steel
other
code Fill Fluid
A
S
G
T
Z
DC 200/350
DC 200/20
glycerin and water
Syltherm 800
other
code display
N
M
Without display
With display
code electrical interface
O
A
B
Z
1/2-14NPT
M20×1/2
Pg13,5 DIN
other
code install
1
2
top
side
code process interface
G
Z
Tri-clamp-3″ 300#
other
code Contact liquid O-ring material
B
V
T
Z
Nitrile rubber (Buna N)
VITON
Polytetrafluoroethylene (Teflon)
other
code Tank adapter
0
1
Without Tank Adapter (to be provided by the user)
Equipped with Tank Adapter
code Tri-Clamp
0
2
Without Tri Clamp
Equipped with Tri Clamp (304 stainless steel)
code Other options (*)
H1
ZZ
316 Stainless Steel Options
Other special options