Welcome Customer !

Membership

Help

Guangzhou Jianlun Biotechnology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Guangzhou Jianlun Biotechnology Co., Ltd

  • E-mail

  • Phone

  • Address

    101, Building A2, No. 63 Chuangqi Road, Tsinghua Science and Technology Park, Shilou Town, Panyu District, Guangzhou City, Guangdong Province

Contact Now

Instruction manual for rapid detection reagent of black fever using colloidal gold method

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Instructions for rapid colloidal gold detection reagent for black fever: Qualitative detection of L. donovani antibodies in human serum using rapid immunochromatography. This experiment helps diagnose visceral leishmaniasis (VL). And only used for in vitro diagnosis. Guangzhou Jianlun Biotechnology Co., Ltd., call: 020-8257 4011 Yang Yonghan

Product Details

Instruction manual for rapid detection reagent of black fever using colloidal gold method

黑热病胶体金法快速检测试剂说明书

Guangzhou Jianlun Biotechnology Co., Ltd. comprehensively supplies professional testing reagents covering drug abuse, animal derived ingredients, cow and sheep milk ingredients, real and fake meat, microorganisms, biosafety, prohibited items, food safety, animal diseases, tropical infectious diseases and other fields. At the same time, it provides routine testing reagents frequently used in scientific research and daily work of disease control systems, providing a one-stop solution for the testing needs of related industries.

Leishmania parasites are a type of parasite that can be transmitted through sand fly bites and can cause black fever. Symptoms of the disease include fever, hepatosplenomegaly, and anemia.

Expected use

This test strip is used for diagnosing visceral leishmaniasis, using rapid immunochromatography to qualitatively detect Leishmania donovani in human serum(L. donated)Antibodies. This experiment helps diagnose visceral leishmaniasis(VL). And only used for in vitro diagnosis.

保存方法

The sealed bag or bottle containing the experimental test strip should be stored in2028(Room temperature) until expiration date. The capture buffer in the bottle should also be stored2028℃. Exposed to more than30Temperature at ℃ can affect experimental performance, so it should be avoided as much as possible. The test strip should not be stored frozen. After being taken out of the sealed bag, it should be1Use within hours to avoid being affected by humidity.

Collection of serum

1Human serum should be used in this experiment. Whole blood samples should not be used as excessive background may affect the correct reading of experimental bands. Serum should be diluted with buffer solution to avoid starting the experiment directly. Positive serum should be diluted with negative serum.

2 After coagulation, centrifuge and separate the serum to avoid hemolysis as much as possible.

3 Experiments should be conducted as soon as possible after serum collection. Serum cannot be stored at room temperature for a long time. Serum in2-8Can be stored at ℃3Oh my god. Otherwise, the serum should be stored in20Below ℃.

4 The serum was equilibrated to room temperature before the experiment. Frozen serum must be thoroughly melted. Avoid repeated freezing and thawing of serum.

5 If serum needs to be transported, its packaging should comply with federal infectious source transportation regulations.

Experimental Procedure

1 Allow the serum to equilibrate to room temperature before the experiment.

2 Remove the rapid test strip for black fever from the sealed bag or bottle

3 Add below the detection bar arrow20 ulThe serum.

4 Place the detection strip in the experimental tube, or96In the micropores of the tissue culture plate, according to the arrow on the detection strip, the end should face downwards.

5 join2-3Drip(150ul)Capture buffer solution

6 in10Read results within minutes. Clear background is crucial before reading the results. Especially when the sample is a low titer anti Leishmania antibody, only a weak band appears in the experimental area(T).10Reading after minutes may result in incorrect results.


黑热病胶体金法快速检测试剂说明书


result interpretation

positive result

If the experiment is positive, both the quality control band and the experimental band appear, as shown in the figure1A positive result indicates the detection of antibodies against Leishmania donovani. A weak color band is also a positive result. As an explanatory guide, the color intensity of the red band in the experimental area is related to the concentration of anti Leishmania antibodies. The experimental band is a "weakly positive" serum sample, and the experimental result may be between a weakly positive red band and a red dot, with almost a white background ("weakly positive" samples contain low affinity or low titer antibodies to recombinant antigens).

Negative result

If the experiment is negative, only the quality control tape appears. A negative result indicates that no antibodies against Leishmania donovani were detected. No experimental tape appeared.

Tropical infectious disease detection kit

Quick and rapid detection kit for chikungunya fever

Ross River Fever IgM Antibody Detection Kit

Quick detection kit for Trypanosoma cruzi

Malaria Antigen Rapid Detection Kit

Quick and rapid detection kit for chikungunya fever

Zika virus rapid detection kit

Yellow fever rapid detection kit

Rapid detection test for black fever

Rapid detection kit for Lassa fever virus

New Bunyavirus Rapid Detection Kit

Leishmania parasite rapid detection kit

RK39 detection kit

Ebola Rapid Detection Kit

Ebola testing kit

American INBIOS Rapid Detection Kit for Black Fever Antibody

Kalazar kalazar antibody detection reagent (Inbios, USA)

RK39 rapid detection reagent for black fever for scientific research

Instruction manual for rapid detection reagent of black fever using colloidal gold method

Guangzhou Jianlun Biotechnology Co., Ltd. also represents:CarestartinbiosLove NovartisINOVA, Andus, USA, AustraliaCellabs, DenmarkSSI, Japanese Graduate School, ThailandSA, GermanyNadal, GermanySIFIN(Serum), Kejie, GermanyQiagen, South KoreaRapiGENMerieux, United StatesFOCUS, United StatesFULLERAmerican Gaozicortez, EuropeFast-track, SpainCertest, SpainVircell, UKOXOID, South KoreaSDFunny, AbbottAbott, United Statesseracarezeptometrix

黑热病胶体金法快速检测试剂说明书

黑热病胶体金法快速检测试剂说明书