| insulation resistance | When the ambient temperature is within the range of (15-35) ℃ |
| When the relative humidity is less than 80% | |
| The insulation resistance value of platinum resistance should be greater than 100M Ω | |
| Self heating effect | Thermal resistance allows a maximum measured current of 2-5mA |
| The resulting temperature rise shall not exceed 0.3 ℃ | |
| Extension tube | Stainless steel, length 130mm |
| Minimum depth of placement | ≥100mm, Excluding special products |
| process connection | Stainless steel, thread/chuck/sheath/flange |
| Protection tube | Stainless steel/titanium/tantalum/Hastelloy/PTFE/wear-resistant materials |
| 8mm,10mm,12mm,16mm | |
| response time | t0.5,10s~120s |
| accuracy class | Pt100, Class A: ± (0.15+0.002 | t |) |
| Grade B: ± (0.30+0.005 | t |) | |
| | t | "is the absolute value of the measured temperature of the temperature sensing element | |
| Junction box | B-type junction box, explosion-proof junction box |
| IP65 (GB4208-1993 standard) | |
| Transmitter | Analog output 4-20mA (see data sheet 7401) |
| wiring method | Two wire system, three wire system, four wire system |
| 防爆形式 | Intrinsic safety type: ia |
| Explosion proof type: d | |
| Explosion proof level group | Ex ia ⅡCT6 |
| Ex d ⅡCT6 | |
| Explosion proof electrical equipment marking GB3836-2000 standard | |
| Equipment category | Class I refers to electrical equipment used underground in coal mines |
| Class II refers to electrical equipment used in factories | |
| Explosion-proof rating | A. Strength or weakness of explosion-proof capability for Class II electrical equipment with levels B and C |
| Temperature Class | Six groups of T1 to T6, the maximum allowable surface temperature of the equipment |
·The standard material for protective tubes, extension tubes, and process connections is stainless steel 1.4301. For other stainless steel materials, please consult our sales staff and indicate them when selecting;
·For special ranges or the use of other temperature sensing components such as Pt500, Pt1000, etc., please consult our sales staff and indicate when selecting;
·When choosing a module with a temperature transmitter, please indicate the temperature range of the transmitter. We will help you set it up together when it leaves the factory;
·The process connection is a flange connection. Please provide flange drawings and relevant standards;
·The standard form of the junction box is B-type. For other types of junction boxes, please consult our sales personnel and indicate when selecting.