Overview

Optional remote sampling ■ Non open lid operation ■ Modbus communication ■ OLED display technology ■ Measurable oxygen and over a hundred toxic gases Overview ◤ Flame retardant structure for continuous detection of toxic gases and oxygen in explosive hazardous areas ◤ Built in microprocessor for self diagnostic function ◤ Adopting detection principles suitable for toxic gases and oxygen to create excellent selectivity ◤ Long term stable quality and proven detection principles ◤ Built in backlit LCD or OLED display screen ◤ Magnetic rod for automatic calibration and program setting ◤ Level 2 alarm, single fault display

Product Details

Optional remote sampling
■ Non open lid operation
Modbus communication
OLED display technology
■ Can measure oxygen and over a hundred toxic gases


Overview

Adopting flame-retardant structure, continuous detection of toxic gases and oxygen in explosive hazardous areas
Adopting a built-in microprocessor to achieve self diagnostic function
Adopting detection principles suitable for toxic gases and oxygen, creating excellent selectivity
Long term stable quality and proven testing principles
◤ Built in backlit LCD or OLED display screen
◤ Use a magnetic rod for automatic calibration and program settings
Level 2 alarm, single fault display, and relay contact output
4-20mA DC output signal
RS-485 Modbus serial communication (optional)
Equipped with alarm device
-Normal: Green LED
-Alarm: Red LED, beep sound (95 dB)
-Fault: Yellow LED
Single person calibration and maintenance

Technical specifications

model GTD-3000Tx
Measuring gases carbon monoxide
measurement method Diffusion type
measurement method Electrochemistry, semiconductor
response time T90<45 seconds
precision ± 3%/full scale
operation method Magnetic rod operation
Work mode display 4-LED (power supply, level 2 alarm, single fault)
Indication display LCD display (built-in backlight dual line, 16 characters)/OLED type (optional)
Alarm signal output 250V 1A/3-stage single pole single throw switch (SPST) relay contacts (2-level alarm, 1-fault)
output signal Simulation: Measurement signal: 4-20mA DC
Maintenance signal: 3mA DC
Calibration signal: 3mA DC
Fault signal: 0mA DC
Digital: RS-485 Modbus (optional)
Cable/Distance Power cable+signal cable: 3-wire>1.5 square (AWG16)/* large: 2500m
RS-485 data communication cable: 1 pair (UL2919 RS-485)/* large: 1000m
Pipe connection G. Rc. NPT 1/2 inch and 3/4 inch (G 3/4 inch: standard)
Installation Type 2-inch pole installation, wall mounted installation, pipe installation
Operating Temperature -20℃ ~ +60℃
Operating humidity 5 ~ 99%. RH (non condensing)
operating power 18~31V DC (conventional: 24V DC)/200mA
size 156 x 196 x 110 (width x height x depth) mm
weight 2.0kg
certification Explosion proof (Ex d IIC T6, IP65) KCs
Explosion proof (Ex d IIC T6 Gb) NEPSI
CE(EN 50270:2006)KC

Physical display

GTD-3000TX-CO.jpg