NexION 1100Inductively Coupled Plasma Mass SpectrometerThe combination of three sets of quadrupole rods and an upgradable gas channel design, as well as a modern workflow, jointly achieves the multiple requirements of simple and efficient interference elimination, low maintenance, and high stability, while also considering the principle of sustainable use. All of these are integrated into a simple and efficient operating system, making it an ideal ICP-MS for daily trace element analysis.
NexION 1100Inductively Coupled Plasma Mass SpectrometerIt is an ICP-MS with three sets of quadrupole design and an upgradable gas channel, with a technical combination of:
The proprietary three group quadrupole design provides three-level mass resolution:
The quadrupole analyzer (Q2, full-size, mass resolution<0.7 amu) is used as a mass filter or ion guiding device to direct ions towards the detector.
The quadrupole universal reaction cell (Q1) comes standard with one gas channel and can be upgraded to dual or triple channels. It has instant gas mixing function and is suitable for collision and reaction modes to enhance interference removal capability
The quadrupole ion deflector (Q0) guides ions into the universal reaction cell (Q1) through different voltages to improve sensitivity to target ions and effectively reduce interference from non target mass numbers.
A single gas channel provides a universal solution for most applications, using helium only in collision mode or a helium hydrogen mixture in collision and reaction modes, making it easier to switch between different modes without changing the gas
A single gas channel is also suitable for pure reactive gases and can be upgraded to dual or triple channels to achieve stronger interference elimination capabilities
The proprietary intelligent electronic dilution technology (EDR) increases the linear dynamic range to 1014, allowing for simultaneous analysis of high and low concentration samples in one analysis run, thereby reducing duplicate testing.
The powerful all matrix injection system (AMS) allows for online dilution of gases, improving efficiency and preventing contamination, providing up to 200 fold dilution, and supporting samples with total dissolved solids up to 35%.
In addition, the innovative free running RF generator uses LumiCoil ™ RF coils (designed specifically for ICP-MS applications) can provide precise impedance matching and easily handle challenging substrates and solvents. This revolutionary combination provides outstanding plasma power and stability, achieving outstanding performance, robustness, and reliability.
Extend normal operation time with low maintenance rate:
The combination of a three cone interface and a QID quadrupole ion deflector requires no maintenance for the parts other than the cone, and can operate continuously to improve stability.
The 34 MHz free running RF generator provides a low fault user experience - the plasma is generated by LumiCoil RF load coils, eliminating the need for water or gas cooling, thus requiring no maintenance or replacement of the plasma load coils.
The innovative LCD touch screen enables you to perform critical daily tasks, including hardware control, result review, instrument parameter diagnosis, analysis, access to embedded training videos, and more.
The external status LED light allows users to easily view the analysis status and optimize laboratory efficiency.
Syngistix ™ The modern database backend of ICP-MS software version v.4.0 is more convenient for LIMS integration, with the new FastQuant ™ The data viewer simplifies the review, reprocessing, and export operations, enhancing the user experience.