·chlorophyll content
·Anthocyanin content
·Flavonol content
·NFI (nitrogen flavonol index)
MPM-100In situ plant pigment measuring instrumentThe combination of mature technologies can simultaneously measure the above different parameters. The standard diode wavelength configuration of the instrument is as follows, and other parameters such as CCI or SPAD diode wavelength can also be measured.
Chlorophyll content:T850nm/T720nm
Flavonol content:F660nm/F375nm
Anthocyanin content:F660nm/F525nm
NFI:(T850nm/T720nm)/(F660nm/F375nm)
advantage
·Using mature technology to simultaneously measure pigments from different plants
·Measurement of anthocyanin and flavonol content using ratio fluorescence
·Using the transmission spectra of leaves in the far-infrared and near-infrared bands to measure chlorophyll content
·Using the results of measuring chlorophyll content and flavonol content to determine nitrogen -Flavonol index
·The measurement mode includes discrete single measurement and average measurement(2-8 samples), the software supports average and median selection.
·2GB non-volatile measurement data memory
·USB output: comma separated data files&Excel open directly
·Touchscreen color interface &Data display
Chlorophyll content is highly sensitive for detecting plant nitrogen and sulfur stress, and is commonly used to manage nitrogen fertilization by measuring chlorophyll content. Chlorophyll content is also used to measure other types of stress in many plants, when the measured value of the tested plant is that of a normally fertilized plant At 90%, nitrogen fertilizer needs to be applied. The measurement band of this system is different from most chlorophyll measuring instruments, and it can also measure nitrogen balance index.
Chlorophyll content:T850nm/T720nm
Flavonoids appear yellow in plants. There is evidence to suggest that they contribute to photoprotection of plants in the ultraviolet spectrum and eliminate reactive oxygen species, thereby protecting plant photosynthesis. Flavonoids can effectively indicate the nitrogen status of plants, and their yellow color can attract pollinating insects.
Flavonol content: fluorescence ratio F660/F375
According to plants Different pH values can appear as red, blue, purple, or colorless. Research has shown that anthocyanins play an important role in temperature protection of plants under stress, attracting pollinating insects and promoting animal seed distribution.
Anthocyanin content: Fluorescence ratio F660/F525
Chlorophyll and flavonols are good indicators of plant nitrogen status. Under suitable conditions, plants produce chlorophyll and small amounts of flavonols. When nitrogen is insufficient, plants produce more flavonols or carbon based compounds,The sensitivity of NFI to leaf age and thickness is lower than that of standard chloroplasts.
nitrogen -Flavonol Index: Chlorophyll to Flavonol Measurement Ratio (T850nm/T720nm)/(F660nm/F375nm)
The ratio fluorescence method has many advantages and can be used to measure very small and opaque samples. The measurement methods for anthocyanins and flavonols are both ratio fluorescence methods.
MPM-100 measures the relative maturity of grapes by removing the thin berry cover with a blade, which can be used to measure the relative maturity of grapes with an instrument.
·Measurement parameters: relative chlorophyll content, relative flavonol content, relative anthocyanin content, and nitrogen -Flavonoid index.
·Measurement area:A circle with a diameter of 9.5mm
·Repeatability:±1%
·Noise:<±2%
·Light source:
·chlorophyll content -Medical grade LED light 720nm&near-infrared LED 850nm
·Flavonol content - LED 375nm&660nm
·Anthocyanin content - LED 525nm&660nm
·Detector: Solid state high-sensitivity detector, supporting band limited filtering settings
·Detection: Modulate the light signal to reduce background interference, and compensate for the temperature of the light source and detector.
·memory2GB non-volatile measurement data memory
·Measurement mode: The measurement mode includes discrete single measurement and average measurement(2-8 samples), the software supports average and median selection.
·Instrument interface:240 × 320 color touch screen
·output:USB
·Operating Temperature0-50℃
·Power Supply:2 AA rechargeable batteries, equipped with a charger
·Automatic shutdown interval:0-20min
·size:180mm×78mm×50mm
·Weight:275g
·Measurement time:5s
·GPS: The positioning accuracy can reach up to 0.3m, and it can record longitude, latitude, number of satellites, and DOP
·Device configuration:MPM-100 GPS multi-color measuring instrument, battery charger, 4 AA NiMH rechargeable batteries, USB cable, portable case, instruction manual.