Welcome Customer !

Membership

Help

Grant Instruments (Cambridge) Limited, UK
Custom manufacturer

Main Products:

instrumentb2b>Products

Grant Instruments (Cambridge) Limited, UK

  • E-mail

  • Phone

  • Address

    Room 1204, Regis Ginza Enterprise Center, 1388 Shaanxi North Road, Shanghai

Contact Now

Imported low-temperature circulating water bath

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Imported low-temperature circulating water bath Grant OptimaTM TX150 series digital refrigeration circulating bath performance, suitable for daily or various high-precision temperature operation applications, with a temperature setting range of -47 ℃ to 100 ℃. The Grant TX150 series refrigeration cycle bath is paired with the high-performance and multifunctional Grant OptimaTM TX150 digital constant temperature controller, offering 5 different capacities of stainless steel refrigeration equipment to choose from

Product Details

Imported low-temperature circulating water bathIt is a high-performance, programmable temperature controller with a full-color QVGA TFT display for actual and set temperatures. The intuitive screen icons and menus allow for quick setting of multiple parameters.
TX150 is programmable and can be remotely controlled by a PC through a USB interface for data storage. Through Labwise? The software can set all parameters, including programming, and display the operating conditions of the controller in real time, while recording data for future retrieval and analysis.

Imported low-temperature circulating water bathcharacteristic

  • Powerful built-in circulation pump: maximum flow rate of 18L/minute (adjustable), maximum pressure of 310mbar

  • Color screen QVGA TFT display

  • Add 3 adjustable preset temperatures to the operating set point

  • Reaction timing, 99 hours, 59 minutes audible alarm and heater control, timer function

  • The temperature range and heating power are safely adjusted according to the type of liquid selected

  • fault display

  • Programming Relay

  • User recalibration of internal and external probes at two points (TXPEP. TXSEP)

  • The temperature compensation function is done * temperature

  • USB port

  • Optional LabwiseTMComputer program settings, data recording, and real-time graphics software

  • Can edit one 30 step program

  • Language options: English, French, German, Spanish, and Italian

  • Low liquid level protection function, achieved through float switch

  • Adjustable over temperature cut-off protection sound alarm

  • Equipped with convenient clamps for easy replacement of the bath

  • 5 types of cooling baths (R series) are available for different conditions, working capacities, and cooling power.

  • Cooling/Heating Range: -47 to 100 ℃ (depending on the selected cooling unit)

  • Stability: ± 0.1 ° C

Note: All refrigeration units can be turned off independently of the thermostat controller. The maximum operating temperature for all refrigeration units is 100 ℃

technical parameters

Grant Optima ™ Technical parameters of constant temperature controller
●=Standard configuration Universal digital type High performance digital type
T100 TC120 TX150 TXF200
Stability (DIN12876) Water at 10 ℃ ±0.1 ±0.1 ±0.1 ±0.1
50% water, 50% ethylene glycol @10℃ - ±0.1 ±0.1 ±0.1
Uniformity (DIN12876) Water at 10 ℃ ±0.1 ±0.1 ±0.1 ±0.1
50% water, 50% ethylene glycol @10℃ - ±0.1 ±0.1
set precision 0.1 0.1 0.1 (0.01 using Labwise) ™ Software)
display mode 4-digit LED Color screen QVGA TFT
timer function - 1 to 9999 mins 1min to 99h59mins
Number of preset temperatures 3 3 3 3
Two-point calibration
Temperature compensation function - -
External temperature probes (TXPEP, TXSEP) - -
communication interface - - USB&RS232 USB&RS232
Programming mode - - PC remote control/1 programming 30 steps Interface control/remote PC control/10 programming 100 steps
relay - - 1 1
safety over-temperature protection fixed Adjustable disconnect
Low liquid level protection - floating on light
Alarm (can set a relay control switch) - - high and low temperature high and low temperature
heating power 230V KW 1.3 1.3 1.9 1.9
120V KW 1.4 1.4 1.4 1.4
total power 230V KW 1.4(50-60Hz) 1.4(50Hz) 2.0(50Hz) 2.0(50-60Hz)
120V KW 1.5(50-60Hz) 1.5(50-60Hz) 1.5(50-60Hz) 1.5(50-60Hz)
Above the height of the edge of the bath mm 200 200 200 200
Depth below the edge of the bath mm 135 135 135 135
Grant Optima ™ Thermostatic circulation pump (built-in)
The biggest pressure Water bar - 210 310 530
Zui high flow velocity Water L/min - 16 18 23 (adjustable flow rate)
Pipeline diameter In/out mm - 6/11 6/11 6/11

R Series Refrigerator - Model and Technical Parameters
Grant Optima ™ circulator
●=Standard configuration R1 R2 R3 R4 R5
Relay control function (refrigeration unit) -
refrigerant R134a R134a R134a R134a R134a
drain outlet -
Over temperature protection function 100 ℃ restriction
Waterproof icing function
High pressure refrigeration switch 27bar - - -
Cooling power, room temperature 20 ℃ @20℃ W 250 250 160 900 1100
@0℃ W 140 140 150 500 1050
@-10℃ W 100 100 120 300 800
@-20℃ W 35 35 50 180 580
@-30℃ W - - 5 40 370
@-40℃ W - - - - 130
@-47℃ W - - - - 25
power 230V W 334(50Hz)* 334(50Hz)* 354(50Hz)* 850(50Hz) 1400(50Hz)
120V W 328(50-60Hz) 328(50-60Hz) 370(60Hz) 780(60Hz) -
Electromagnetic Radiation Registration class B B B B B

*Optima ™ The temperature controller and accessory pump can be powered through the R1, RW, and R3 220-240V refrigerator back sockets. The power of the refrigerator is increased by an additional 2kW

**The optional VTP pump will bring an additional two liang to the bath, so without refrigeration accessories, the lowest temperature that the bath can reach will increase.

Attention: When ordering a VTP pump, please indicate the model of the Grant bath that comes with it.