Welcome Customer !

Membership

Help

Shanghai Xinyi Precision Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Shanghai Xinyi Precision Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 719, Jiurun Business Building, No. 23, Lane 466, Yindu Road, Shanghai

Contact Now

Imported brand of flame photometer

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The imported brand of flame photometer has made significant improvements based on our original product, simplifying the gas system and using liquefied petroleum gas (LPG) as fuel. Equipped with a flameout protection device, greatly improving safety. This instrument has the advantages of small size, simple structure, easy operation, stability and reliability. It has the function of pre-set flame size. The display screen can show decimal points and can be freely adjusted.

Product Details

Imported brand of flame photometerProduct features
The FP640 flame photometer has been greatly improved based on our original product, simplifying the gas system and using liquefied petroleum gas (LPG) as fuel. Equipped with a flameout protection device, greatly improving safety. This instrument has the advantages of small size, simple structure, easy operation, stability and reliability. It has the function of pre-set flame size. The display screen can show decimal points and can be freely adjusted.
The completeness of the instrument set
1) 1 instrument (host)
2) 1 air compressor
3) 1 set of accessory spare parts
Normal working conditions
1. Environmental temperature (10-35) ℃.
2. Relative humidity ≤ 85%.
3. The power supply voltage is (220 ± 22) V, the frequency is (50 ± 1) Hz, and it has good grounding.
4. The rated power is 30W.
5. The product should be placed horizontally on a non vibrating workbench, and there should be no shaking during operation.
6. The testing site should have good ventilation and should not be directly exposed to strong light. There should be no interference from strong magnetic fields, electric fields, or vibration sources around the product, and no strong airflow.
7. There should be no flammable, explosive, or corrosive gases on site when using liquefied gas cylinders for the product, and fire extinguishing facilities should be prepared.
Imported brand of flame photometerTechnical indicators
Stability: Continuous injection with standard solution, relative maximum change in instrument reading within 15 seconds ≤ 3%
Measure once per minute for a total of 6 measurements, with a relative maximum change in instrument readings of ≤ 15%
Repeatability: ≤ 3%
Linear error: K: ≤ 0.005mol/L (0.0100-0.0800) mmol/L;
Na:≤0.03mmol/L(0.0500~0.400)mmol/L
Detection limit: K: Detection limit ≤ 0.004mmol/L;
Na: Detection limit ≤ 0.008mmol/L
Transmittance characteristics of filter: Potassium filter: absolute value of peak wavelength error ≤ 7nm;
Sodium filter: absolute value of peak wavelength error ≤ 5nm
Potassium filter: half width ≤ 15nm;
Sodium filter: Half width ≤ 15nm
Potassium filter: background transmittance ≤ 0.5%;
Sodium filter: background transmittance ≤ 0.5%
Response time:<8s
Sample suction and spraying volume: < 6mL/min
Display mode: LCD screen display
Spectral splitting method: interference filter
Optoelectronic conversion element: silicon photovoltaic cell
Dimensions l × b × h: 400 × 250 × 500 (mm × mm × mm)
Mass (weight) kg: 8.0
Test range: K: 0-50ug/ml
Na:0~160ug/ml