Welcome Customer !

Membership

Help

Tianjin Klerui Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Tianjin Klerui Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    Juncheng Business Center, No. 85 Xihu Road, Nankai District, Tianjin

Contact Now

Imported BUEHLER sampling pump gas analyzer sampling probe

NegotiableUpdate on 05/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

BUEHLER Technologies gas analyzer, BUEHLER Technologies liquid level switch, measuring probe, BuhlerTechnologies gas analyzer, BuhlerTechnologies dust detector, BuhlerTechnologies float switch, temperature switch, BuhlerTechnologies gas detector, flow meter. Imported BUEHLER sampling pump gas analyzer sampling probe

Product Details

BUEHLER Technologies gas analyzer, BUEHLER Technologies gas sampling probe, BUEHLER Technologies gas filter, BUEHLER Technologies sampling air pump, BUEHLER Technologies gas condenser, BUEHLER Technologies flow meter, BUEHLER Technologies nitrogen oxide (NO2-NO) converter, BUEHLER Technologies gas analyzer, BUEHLER Technologies liquid level switch, measuring probe, BuhlerTechnologies gas analyzer, BuhlerTechnologies dust detector, BuhlerTechnologies float switch, temperature switch, BuhlerTechnologies gas detector, flow meter

====================================

BUEHLER Technologies Company Introduction

B ü hler Technologies GmbH is a medium-sized enterprise headquartered in Germany, specializing in the research and development, manufacturing, and sales of components and system solutions in the fields of gas analysis technology and fluid control. It is one of the few global suppliers specializing in a full range of hydraulic system gas analysis and fluid control. In addition to the series of products designed and continuously optimized by its independent research and development department, BUEHLER has also developed highly personalized solution applications. For over 45 years, BUEHLER Technology has been providing customized environmental industrial solutions for customers in the process, chemical, petrochemical, power plant, and other energy industries - for which they have an undeniable responsibility. In the hydraulic field, BUEHLER Technology provides connected sensors and systems for monitoring and stabilizing process parameters, thereby improving efficiency and oil product life in the long term. BUEHLER Technology's quality management system has passed the Lloyd's Register Quality Assurance certification in the UK and holds the EN ISO 9001 certificate.

The main products of BUEHLER in Germany include measurement probes, Buhler Technologies gas analyzers, uhler Technologies dust detectors, Buhler Technologies float switches, temperature switches, Buhler Technologies gas detectors, flow meters, etc.Imported BUEHLER sampling pump gas analyzer sampling probe

=================================

BUEHLER Technologies Product Introduction:

Corrosion-resistant material

simple structure

The measuring tube is easy to replace

Limit switch optional

Durable and easy to protect fuse

Widely applicable

High safety standards

In addition to simply monitoring and regulating flow, flow meters can also be used to monitor the pollution level of upstream filters in the flow meter in the processing pipeline.

For this purpose, the BUEHLER Technologies flow meter SM-6 can be equipped with an electrical limit switch on the measuring tube. They are connected to the control system through appropriate isolation amplifiers.

The version with integrated needle valve also allows setting specific flow values.

Some applications in liquid and gas analysis require strengthened safety precautions, including flow meters.

It is particularly important to protect transparent measuring tubes from mechanical damage. This series achieves this goal by using sturdy slotted protective tubes made of stainless steel.Imported BUEHLER sampling pump gas analyzer sampling probe

Although the measuring tube wall is already very thick, the stainless steel shell can naturally protect the environment and prevent the glass tube from bursting.

In gas analysis and processing systems, flow meters perform various tasks.

Typically, very demanding applications require the use of highly corrosion-resistant materials and a high level of operational reliability.

Reliable analysis results require constant operating conditions. This also includes precise adjustment and monitoring of traffic.

Like all other components that come into contact with the medium, the key to a suitable flowmeter is to choose highly durable materials and easy to maintain.

Inductive limit switches and corresponding wiring devices allow the flow meter to be integrated into the system control.

------------------------------------------

BUEHLER Technologies Gas Cooler Series TC-MIDI-H2/- O2

Suitable for applications with high-purity hydrogen or oxygen

The cleaning standard is based on EIGA Doc 33/18, which states that the O2 type heat exchanger does not contain particles, oil, and grease

Materials in contact with the medium undergo high concentration H2 and O2 suitability testing

Perform standard leak testing on H2 heat exchangers using helium gas

Nominal cooling capacity of 195 kJ/h (40 ° C version) or 175 kJ/h (50 ° C version)

Constant dew point stability ± 0.1 ° C

Output dew point and alarm threshold adjustable

Cooling block temperature display

Optional signal output 4-20 mA or Modbus RTU

Low leaching effect

Compact design: pre assembled, can be directly connected

Due to good accessibility and low maintenance costs

Optimized Type 2 heat exchanger made of Duran glass or PVDF

Output dew point and alarm threshold adjustable

Nominal cooling capacity of 100 kJ/h (40 ° C version) or 90 kJ/h (50 ° C version)

Dew point stability at 0.1 ° C

Status display and output

Cooling block temperature display

Optional signal output 4-20 mA or Modbus RTU

Optional CE mark or FM certification

Optional humidity sensor, filter, and condenser pump

The TC-MIDI sample gas cooler with heat exchanger-H2/- O2 is an ideal solution for reliably cooling hydrogen (H2) and oxygen (O2) when strong cooling is required in gas extraction analysis. The use of renewable energy to produce green hydrogen through electrolysis is key to achieving a sustainable and emission free energy future.

Many analytical methods require extracting sample gases from the process. Pollutants related to the process, such as particles or moisture, will also be removed. These may affect the measurement results or damage the measuring unit. Therefore, the sample gas must be adjusted before entering the analyzer. As a result, the gas temperature in the sample gas cooler drops below the dew point, causing water to be analyzed and discharged in the form of condensate.

The BUEHLER Technologies gas cooler series TC-MIDI-H2/- O2 with - H2/- O2 heat exchanger is an ideal solution for reliably cooling hydrogen (H2) and oxygen (O2) in gas extraction analysis when a compact design is required. The use of renewable energy to produce green hydrogen through electrolysis is key to achieving a sustainable and emission free energy future.Imported BUEHLER sampling pump gas analyzer sampling probe

Suitable for applications with high-purity hydrogen or oxygen

The cleaning standard is based on EIGA Doc 33/18, which states that the O2 type heat exchanger does not contain particles, oil, and grease

Materials in contact with the medium undergo high concentration H2 and O2 suitability testing

Perform standard leak testing on H2 heat exchangers using helium gas

Rated cooling capacity of 100 kJ/h (40 ° C version) or 90 kJ/h (50 ° C version)

Constant dew point stability ± 0.1 ° C

Output dew point and alarm threshold adjustable

Cooling block temperature display

Optional signal output 4-20 mA or Modbus RTU

Due to good accessibility and low maintenance costs

Can set two independent temperatures

Can perform two-stage cooling

Heat exchangers made of stainless steel, Durand glass, or PVDF

Output dew point and alarm threshold adjustable

Nominal cooling capacity of 270 kJ/h (40 ° C version) or 310 kJ/h (60 ° C version)

The maximum ambient temperature is 60 degrees Celsius

Dew point stability at 0.1 ° C

Status display and output

Display cooling block temperature

Optional signal output 4-20 mA or Modbus RTU

Optional CE mark or FM certification

Optional humidity sensor, filter, and condenser pump

--------------------------------------

BUEHLER Technologies Sample Air Pump P2.2 ATEX-H2/- O2

Suitable for applications with high-purity hydrogen or oxygen

Perform standard leak testing on H2 variant using helium gas

Extract sample gas containing condensate (pump head rotated 180 °)

The cleaning standard is based on EIGA Doc 33/18 and does not contain particles, oil, and grease (O2 variant)

Materials that have undergone high concentration H2 and O2 suitability testing

All plastics in contact with the medium have undergone BAM testing (O2 variant)

Production under controlled cleaning conditions according to VDA Volume 19.1 (O2 variant)

All advantages of standard measuring air pump P2. x ATEX

Easy to replace valves

Integrated corrugated pipe

Transport sample gas containing condensate

Mature pump technology

Attractive prices

Compact size

Optional installation accessories and screw connections

Shell version IP20

Optional integrated bypass valve

Provide 24V version

12 V version can be provided upon request

FM C-US certification (ordinary venue) optional

Simple and sturdy structure

Easy to replace valves

Integrated corrugated pipe

Transport sample gas containing condensate

long service life

Atex version (see separate data sheet)

Low noise emissions

The 115V version has obtained FM C-US certification

Type C is specifically designed for transporting gases

Bypass valve for PTFE and VA pump body

For process control or emission monitoring in the chemical, petrochemical, or biochemical industries, gas analysis is crucial for the safe and efficient operation of factories. P1.1 pumps are also very suitable for maritime applications and are widely used at sea. Many analytical methods used in these fields require extraction and processing of sample gases.Imported BUEHLER sampling pump gas analyzer sampling probe

BUEHLER Technologies sample air pump P2.2 ATEX-H2/- O2 is crucial for process control or emission monitoring in the chemical, petrochemical, or biochemical industries, and gas analysis is essential for safe and efficient factory operation. Many analytical methods used in these fields require extraction and processing of sample gases.

Gas analysis is also crucial for the safe operation of potential explosive factories in the chemical, petrochemical, or biochemical industries. Many analytical methods used in these fields require extraction and special treatment of sample gases. Suitable for Atex Zone 2 gases and environments

The use of renewable energy to produce green hydrogen through electrolysis is key to achieving a sustainable and emission free energy future. Their specially developed P2. x ATEX-H2/- O2 measuring gas pump is an ideal solution for reliable gas preparation in hydrogen (H2) and oxygen (O2) analysis.

-------------------------------------

BUEHLER Technologies Aggregation Filter K-AGF-PV-30-A

Breuer's unique quick release device

Easily and quickly replace filter cartridges without the need for tools

Variable wall mounted installation

The additional connection (G1/4) in the filter head is used for humidity sensors or bypass

Can be connected to an automatic condensate drain

Breuer's unique quick release device

Easily and quickly replace filter cartridges without the need for tools

Low dead volume

Variable wall mounting through cushion blocks

Drain condensate through the connecting thread (G3/8) in the filter housing

Bypass connection inside the filter head (G1/4)

Easily and quickly replace filter cartridges without the need for tools

Low dead volume

Variable wall mounting through bracket installation

The condensate can be automatically drained through the connecting thread (NPT 1/4 ') in the filter cup

In special applications of gas technology, gas maintains high pressure in the system.

The aerosols contained in the gas in such systems are also one of the adverse interferences.

These water-based suspended particles can be easily removed from the gas through coagulation in a special filtering matrix.

Another interference that must be removed in measuring gases is aerosols.

BUEHLER Technologies Aggregation Filter K-AGF-PV-30-A

The BUEHLER Technologies coalescing filter K-AGF-PV-30-A is a very complex field. In order to obtain representative and reliable analysis results, it is necessary to sample and process the sample gas to be analyzed under very different conditions.

BUEHLER Technologies coalescing filter K-AGF-PV-30-A These water-based suspended particles can be easily removed from gases through coagulation in a special filtering matrix.

During this process, tiny aerosols collide with the fibers of the filtering matrix and form increasingly larger droplets. If the filter is large enough, the condensate formed will flow down into the filter cup and be discharged.

The K-AGF-PV-30-A model adopts PVDF and glass shell of AGF-PV filter series, and adapts to condensation function through appropriate internal structure. Easy installation and unique quick release are other advantages of this type.

-------------------------------

BUEHLER Technologies Sampling Air Pump

A small sampling air pump that can be installed in the analyzer cabinet. Optional protective casing. The specially designed corrugated tube pump can transport humid sample gases. Use in a safe area. Optional installation accessories, bypass valve. Multiple power supply options available (12) 24 V DC, 115 V AC, or 230 V AC 50/60 Hz. The flow rate is as high as 280 l/h. In process control or emission monitoring applications in the chemical, petrochemical, or biochemical industries, gas analysis is crucial for ensuring safe and effective factory operations. Many gas analysis methods used in these fields require the extraction of sample gas and pre-treatment of the sample gas before it enters the analyzer.

--------------------------

BUEHLER Technologies gas condenser

The feature of the RC 1.2+series is the use of a new generation of heat exchangers, which have a particularly low leaching effect on water-soluble components and are particularly suitable for emission monitoring. Especially, the leaching effect of SO2 is very low. Therefore, RC 1.2+cooler can be used for automatic measurement systems (AMS) according to EN 15267-3. In addition to the status output for monitoring the function of the sample gas cooler, a 4-20 mA analog output or digital interface can also be optionally selected. Process control can access process and diagnostic data through Modbus RTU interface and be set in device configuration.

---------------------------------

BUEHLER Technologies Gas Sampling Probe GAS 222.10

Heat to 180 ° C

115/230 volts

basic unit

Equipped with self-adjusting heating function

Low temperature alarm 140 ℃

insulating sheath

Including flange seals and screws

The gas sampling probe constitutes a critical interface between the process and analysis system. They must be able to extract undoped sample gases from the process flow and further transport them to the analysis system.

In addition, they should remove unwanted impurities at the extraction point and cannot form cold bridges, as cold bridges may cause measurement distortion through condensates.

The maintenance of BUEHLER Technologies gas sampling probe GAS 222.10 must be simple and do not require the use of a large number of tools. Appropriate construction must be carried out to meet critical environmental conditions such as explosion or wind and rain resistance.

A non heating probe equipped with an outlet filter, suitable for indoor installation.

Rotate the handle 90 ° to easily remove the filter element.

Suitable for non condensable gases with a dust content of up to 2g/m ³.

This probe does not have its own ignition source, so it is suitable for use in hazardous areas.

Basic unit.

Including flange seals and screws.

unheated

Basic device with manual shut-off valve

Suitable for in-situ and outlet filters

Equipped with backwash interface

Simply rotate the handle 90 ° to easily remove the outlet filter

Suitable for non condensable gases with a dust content of up to 2g/m ³. When used in conjunction with an intake filter, it can reach 10g/m ³ or even more

Including flange seals and screws

This probe does not have its own ignition source, so it is suitable for use in hazardous areas

Version certified by Atex and IECEx

Non heating probe with shut-off valve and/or inlet filter

Rotate the handle 90 ° to easily remove the filter element

Suitable for non condensable gases with a dust content of up to 2 g/m3. When used in conjunction with an intake filter, it can reach 10 g/m3 or more

This probe is suitable for use in potential explosive areas

Used in Zone 1 and Zone 21, and removed from Zone 0 and Zone 20

----------------------------

BUEHLER Technologies Flow Meter S-SM

Due to the need to observe gas flow through a transparent glass graduated tube, the fragility of the flowmeter has become a weak point in the entire analysis system, and the graduated glass may become a leakage source for key gases or liquids. For such special working conditions, Beile designed an S-SM safety flowmeter: the outer wall of the coaxial safety metal sheath and the scale glass tube are in contact, and the observation point is open. This design greatly reduces the potential danger.

------------------------------------

BUEHLER Technologies gas analyzer

Portable analysis BA 4510 is used to measure trace amounts of oxygen in inert gases. We have adopted a mature, maintenance free zirconia detector. This oxygen ion conductor combines the advantages of high selectivity, high mechanical stability, and consistency. As the oxygen content decreases in the inert gas, the voltage of the zirconia cell increases, allowing for the measurement of trace amounts of oxygen. The internal processor converts the measurement signal into oxygen concentration, displays it on the LCD screen, and can output it as an analog current signal. If the initial pressure of the sample gas is too low, necessary airflow needs to be provided through an internally switchable air pump. The analyzer adopts a graphical menu and is set through thin film buttons. The special version (BA 4510 KIZ) can be used to measure gases with components.

--------------------------------

BUEHLER Technologies gas filter

Although particulate impurities have been removed by the sampling probe at the sampling point, there is still a risk of ultrafine particulate matter being extracted into the gas analysis system. Therefore, for online, mobile, and portable gas pretreatment, precision filters need to be installed. The precision filters produced by Beile are divided into online filters or panel filters, and their housings are made of various combinations of different materials. Equipped with easily replaceable filter cartridges of various materials, with different filter diameters and multiple filter sizes, it can be widely used in various working conditions.


==========================================

Main product models of BUEHLER Technologies

BUEHLER Technologies Heated Filter AHF-22

BUEHLER Technologies Aggregation Filter K-AGF-PV-30-A

BUEHLER Technologies Aggregation Filter K-AGF-VA-23

BUEHLER Technologies Aggregation Filter K-AGF-VA-350

BUEHLER Technologies Sampling Air Pump P 1.1

BUEHLER Technologies Sampling Air Pump P 1.2

BUEHLER Technologies Sampling Air Pump P 1.3

BUEHLER Technologies Gas Condenser TC-MIDI+

BUEHLER Technologies Gas Cooler Series RC 1.2+

BUEHLER Technologies Gas Condenser TC-MIDI

BUEHLER Technologies Gas Cooler Series RC 1.1

BUEHLER Technologies Gas Condenser TC standard

BUEHLER Technologies flow meter SM-6

BUEHLER Technologies Safety Flow Meter S-SM

Level gauge NS 10/NS 25

BUEHLER gas probe GAS 222.20

BUEHLER sampling gas probe GAS 222.20 ATEX

BUEHLER gas probe GAS 222.21 Ex2

BUEHLER gas probe GAS 222.20 AMEX

BUEHLER Portable Oxygen Analyzer BA 4510

Oxygen BA 4000 injection in BUEHLER food packaging

BUEHLER Multi channel Gas Analyzer BA 3 select

BUEHLER flue gas oxygen analyzer BA 2000

BUEHLER Zirconium Oxygen Analyzer BA 1LT

BUEHLER AGF-PV 30,AGF-VA 23,K-AGF-VA-23

Gas filter AGF-FE

Air pump P2. x P2.8x

Gas filter ADF-PV-30-L

Gas filter K-AGF-PV-30-A

Gas filter AGF-VA-350

NS-10/25-AM-K7,5-SK166-/-700-DN25-PN40-DIN-2656-L1-

000033039-1122000-67627-MK2-G1/2-MS-M3/370-with-PT100-

3004999-WW-6/SW-with-changeable-contact

41010010-Filterelement-S2-

EK2-G1/2-VA-M3/200EK2-G1/2-VA-M3/200

EK2-G1/2-VA-M3/500EK2-G1/2-VA-M3/500

MK2-G1/2-MS-M3/300MK2-G1/2-MS-M3/300

NS-10/25-AM-K5-SK166-/-800-level