Beckman Coulter ACCESS 2 chemiluminescence immunoassay analyzer | |
![]() | |
|
ACCESS 2 chemiluminescence immunoassay analyzer |
|
| immunology principle | |
| -Antigen antibody specific binding | |
| -Small molecules use (one-step, two-step) competitive binding method | |
| -The large molecule adopts the sandwich method (one-step, two-step) | |
| Third generation AMPPD | |
| -Internationally recognized third-generation mature and stable luminescent substrates | |
| -High detection sensitivity, up to 10-21 | |
| Magnetic Particle Technology | |
| -Magnetic particles d<7u | |
| -Expand surface area and increase sensitivity | |
| -Accelerate reaction speed, quickly capture antigens and antibodies | |
| -Easy to separate bound and free phases, improving accuracy | |
| -Improve luminous intensity, quickly achieve stable and continuous luminescence | |
| Reagent system | |
| -Six layer membrane reagent kit sealing technology effectively improves reagent storage and utilization rate | |
| -The puncture function of the reagent system effectively reduces contamination of the reagent probe during the reaction process | |
| -Each reagent kit contains five reagent compartments, and no auxiliary reagents need to be added during the reaction process | |
| -In desktop computers, the ACCESS 2 chemiluminescence immunoassay analyzer has the largest reagent supply position and can simultaneously perform testing for 24 items | |
| Ultrasonic cleaning and mixing technology | |
| -Unique ultrasonic automatic cleaning probe ensures cross contamination rate<10ppm | |
| -Using ultrasound to mix reagents and mixtures, avoiding the drawbacks of oscillating mixing methods | |
| Powerful emergency function | |
| -Truly 24-hour standby, ensuring emergency testing results within 10-20 minutes | |
| -At least 100 experiments per hour | |
| -Automatic dilution and retesting function | |
| Central control and supply system | |
| -Simple and easy to learn intelligent Chinese operation software | |
| -Powerful programming, data query, calibration, quality control, and assistance systems | |
| -Ability to operate a laboratory workstation with a single processor connected to 4 instruments simultaneously | |
| -24 reagents are stored in the instrument's own refrigeration system, and do not need to be taken out before all reagents are used up | |
| -A standard curve that is stable and long-lasting for more than 28 days | |
| Sample processing system | |
| -60 original tubes can be loaded onto the machine at once, and can be continuously added without interruption of operation | |
| -Random combinations of sample testing items and emergency specimens have priority authority | |
| -Raw tube, sample, reagent barcode input | |