Instrument Overview: One measuring position, with functions such as automatic temperature control, automatic measurement, automatic calculation of viscosity value, automatic discharge of waste liquid, automatic cleaning, automatic drying, and data processing.
Instrument design principle: Using the Ubbelohde viscosity method to measure the kinematic viscosity, dynamic viscosity, viscosity ratio, viscosity number, specific viscosity, increased viscosity, intrinsic viscosity, polar viscosity number, polymerization degree, viscosity average molecular weight, etc. of polymer or copolymer, Newtonian fluid, etc.
Application fields:
lPET、PBT、PBAT、PBS、PA、PES、PVC、PAM、PAA、PVDF、ACR、POM、PAAS、HA、PLA 、PGA、PLGA、PMMA、PEEK、PAN、PC、 Hyaluronic acid, aramid, polysulfone, cellulose, polysaccharides, and organosiliconwait.
lPE、PP。
lFuel oil, lubricating oil, and other mineral oils, oil agents, etc.
Applicable standards:GB/T14190、GB/T17931、ISO1628、ISO307、ASTM D445、ASTM D446、GB/T 265、SY/T5651 Pharmacopoeia, etc.
|
Instrument Overview:One measuring position with functions such as automatic temperature control, automatic measurement, automatic calculation of viscosity value, automatic discharge of waste liquid, automatic cleaning, automatic drying, and data processing.
|
Equipment functions and features
Instrument structure |
lThis instrument is an intelligent module combination structure. It can be combined into a viscosity testing instrument that maximizes the satisfaction of user needs according to their different technical requirements. Each set is mainly composed of1 control module、1 piecemeasurementmoduleandcommunication line、1 pieceautomatic cleaningmodule、1 pieceConstant temperature bath、1 temperature control module、1Taiwancooling module、Ubbelohde viscosity tube、control softwareandPC machineWaiting for composition. |
|
IV-MC(I)
control module
|
lIt is the central module of the system and is implemented simultaneouslyConnection between PC and various components.
lAnd measurement module andThe communication interface of the PC is a USB interface, which is very convenient to plug and unplug.
lThe 8-channel control system can accommodate up to 8 measuring stations working simultaneously.
|
|
IV-X
measurement module
|
lKe AnInstall different standardsSpecificationsA capillary viscometer, such asUbbelohde viscosity tube、Automatic Pinshiviscositypipe.
lEquipped with automatic constant temperature control、Enhance samples、Timing function. Only one control module is neededConnection of USB communication cable.
ladoptImported lifting pump and armored stainless steelinfraredfiber optic sensor.
lMeasurement method: photoelectric method.
lApplicable temperature range:-10~150℃.
lmeasurementTime range:0~9999.99s.
lTiming accuracy:≤0.01s.
lViscosity range:0.3~50000 mm ²/s (depending on the viscosity meter used)).
|
|
SCL
Automatic cleaning module
|
lIt has automatic waste discharge, automatic cleaning, and automatic drying functions.
lEach automatic cleaning module is equipped with an independent drainage pump, and the waste liquid collection is independent of each other.
lCleaning and drying methods: back and forth multiple times for cleaning, dual air path drying.
lThe measurement module and cleaning module adopt a split design and a one-to-one approach.
lReagent quantity: <13ml。
|
|
HT constant temperature bath and
WK-XTemperature Control Module
|
lCan be placed at mostTwo measurement modules.
lMaterial: Stainless steel inner and outer shells, double-layer tempered glass windows.
lThe dual chamber design structure ensures long-term consistency and temperature control accuracy of the bath solution in the measurement area of the bath.
lIt has high and low liquid level alarm and ultra-high temperature protection functions.
lThe temperature calibration function can be set up by oneself.
lWorking temperature range:20~100℃。
lTemperature fluctuation:≤±0.01℃。
ltemperaturedisplayResolution:0.001℃.
lCirculating pump speed digital display adjustable:200-1900 revolutions per minute.
|
|
V1.0
Control operation software
|
lAutomatic result calculation processing, automatically converting kinematic viscosity, dynamic viscosity, relative viscosity (viscosity ratio), viscosity number, specific viscosity, increased viscosity, intrinsic viscosity, ultimate viscosity number, polymerization degree, viscosity average molecular weightequivalence.
lIt has functions such as measuring out of tolerance compensation and three-level permission management.
lThe number of repeated measurements for a single sample can be set by oneself(1-99 times).
lIt has functions such as result query, report preview, long-term result analysis and statistics, export, and connecting to a printer to print reports;
lEach workstation is controlled by an independent operating interface.
lOperation interface: Chinese and English are optional.
|
|
Water, electricity, gas, etc
External condition requirements
|
l220Vambush50 Hz,Power:2KW
lIt is best to place the device inside a fume hood or under a ventilation hood
lworktemperature-5 to 40 ℃,workhumidity ≤ 75% RH (non condensing)
lEquipment dimensions (length)*Width * Height: 830 * 245 * 580mm
|