IP68 Ultrasonic Water Level Gauge

NegotiableUpdate on 12/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Our IP68 ultrasonic water level gauge uses chips imported from TI and SMT. Users can check the electronic components themselves, which are made of internationally produced high-precision CPUs imported from the United States. We come standard with multiple signal outputs, circuit board gold plating technology, and durable protection against oxidation that may cause performance degradation. We use an ABS integrated shell with a 45 degree angled waterproof joint design, multi-layer anti-corrosion sealing, and the lid and electrical interface can achieve IP68 for the entire machine under tightened conditions
Product Details

1IP68 Ultrasonic Water Level GaugeProduct advantages:

1In terms of raw materials, our chips useTIandSMTImported, this user can view the electronic components themselves using high-precision international productionCPUUS import

2In terms of circuit technology, we come standard with multiple signal outputs. The circuit board is made of gold-plated technology, which is durable and provides protection against oxidation that may reduce performance

3In terms of structural components, we chooseABSIntegrated shell, with its45The design of the angled waterproof joint, multi-layer anti-corrosion sealing, and the tightening conditions of the cover and electrical interface can achieve the whole machineIP68Suitable for all working conditions and measurement of any liquid

4In terms of production technology, we carefully select each component and aging them48More than three calibration tests for the entire machine, with a minimum of one hour

5Multiple probes are available, including semi enclosed standard probes, semi enclosed standard probes, and fully enclosed anti-corrosion probes, suitable for measuring various media

6Our two-wire ultrasonic level gauge is4-20maCircuit power supply,4The wired system comes with both default and built-in settings4-20ma+moudbs485+2Relay, output4-20mAThe wiring terminal is connected as a power terminalDC24VIt won't burn either

7、 可以定制AC220VPower supply, the vast majority of manufacturers on the market only haveDC24Vpower supply

8Wide voltage power supply, signal isolation design,DC6V-30VThe factory isDC24VCalibrate the factory and provide for each product

9When operating the large LCD menu, it is clear at a glance, and each function is clearly visible. The manual provides detailed operation steps

IIIP68 Ultrasonic Water Level GaugeTechnical Specifications

Measurement range:5mThe10mThe15mThe20mThe25m(Selected based on the measured range)

blind District:0.25m0.6m

Distance measurement accuracy:0.25%0.5%(Standard conditions)

Distance measurement resolution:1mm

press 力:4Below one atmosphere pressure

Instrument display: built-inLCDDisplay liquid level or spatial distance

Analog output:420mA

Digital output:RS485 / ModbusProtocol or customized protocol

Supply voltage:DC12V /DC24V / AC220VBuilt in lightning protection device

Environmental temperature: -20℃ ~ +60℃ (please specify for high temperature customization)

Protection level:IP65 / IP68

3、 Installation method:

If it is in an open environment, the bracket installation method is generally used, and the instrument is fixed with its own flange or nut, with standard thread for the instrumentG2Can match various specifications of flanges(PPFlanges, carbon steel flanges, stainless steel flanges, to be matched according to actual on-site needs. If the pool or tank is cut slightly larger than the probe diameter at the installation position(60mm)Insert the instrument into the circular hole and tighten the flange or nut from bottom to top. Installation must ensure that the probe surface of the instrument is level with the measured liquid level

The wiring of the instrument depends on whether the selected instrument is a two-wire or four wire system. By referring to the instruction manual, the wiring can be quickly connected. If the range needs to be changed, follow the operating steps to make the changes

4、 Instrument debugging (see operating manual for details):

Liquid level calibration:After the instrument is installed and powered on, the liquid level value will be displayed on the LCD, but this data often does not match the actual liquid level, so liquid level calibration is required. as long asP04Once the menu is set, the liquid level calibration will be automatically performed(Liquid level valueH)And distance calibration(spacing valueL).

full scale20mACorresponding value setting(P02)

Press when the instrument is working normallySETEnter the parameter settings menu with the key, press the ▲ key to selectP02The menu, the second line of numbers is20mACorresponding liquid level, pressOKSet the key.

Probe installation height setting and automatic liquid level calibration(P04)

P04The menu is for setting the installation height of the probe, which must be a true and valid value. After setting the effective installation height value, it will be automatically calibratedHandLvalue(namely:Liquid level value and spatial distance).

Reaction speed setting(P05

P05The menu can change the instrument response speed. The faster the liquid level changes, the faster the corresponding instrument response speed is required. This instrument has4Medium mode available for selection:00 The fastest response speed;01 Faster response speed;02 Medium speed response speed;03 Slow response speed.

Press the ▲ key to select the desired mode and then pressOKConfirm with the key.

[Attention]The faster the response speed of the instrument, the greater the fluctuation of the displayed data; On the contrary, the slower the response speed of the instrument, the more stable the displayed data. If the liquid level does not change very quickly, there is generally no need to modify the factory settings.

IDNumber setting(P07)(Note: Only the four wire system has this function!)

When used for communication, especially for multi machine communication, the default is01.

Relay output setting (note: only four wire system has this function!)

The instrument is equipped with two relays, namelyH(upper limit)L(lower limit). PressSETKey, password interface appears:“0000”Press the [▲] key to change one digit of di to3, press【OK】Press the key to enter the relay parameter setting menu interface.

Each set of relays has two parameters corresponding to it, namely the control value and the hysteresis value.H(upper limit)Relay is determined by menu parametersH(Control value) anddH(Return difference value) control;L(lower limit)Relay is determined by menu parametersL(Control value) anddL(Return difference value) control.

For high point relays(H)When the measured value changes from small to large and exceeds the control value(H)When the relay is closed; When the measured value is less than the difference between the control value and the return value(H-dH)The relay is disconnected.

For low point relays(L)When the measured value changes from large to small and is less than the control value(L)When the relay is closed; When the measured value is greater than the control value plus the difference value(L+dL)The relay is disconnected.

Relay (alarm type)

pressSETThe password interface appears on the key“0000”Press the [▲] key to change one digit of di to4, namely:“4000”, press【OK】The key can enter the relay settings,PH:01For high-level alarm,PL02For low-level alarms, set the alarm type according to the requirements (for example, if two high-level alarms need to be set as)PH:01ThePL:01Low level alarm is set toPH:02ThePL:02This function can be achieved.