- Phone
-
Address
503, Block E, Building 1, Huasheng Longyue, Jinglong Community, Longhua Street, Longhua District, Shenzhen
Shenzhen Kyoto Yuqi Electronics Co., Ltd
503, Block E, Building 1, Huasheng Longyue, Jinglong Community, Longhua Street, Longhua District, Shenzhen
INFLIDGE digital temperature controller with flow sensor
INFLIDGE digital temperature controller with flow sensor
The digital thermostat DAC-8EF adds air volume adjustment function to the popular DAC-8E, making it affordable. It
It can accurately control the hot air temperature of the air heater. just
Connect the air heater and supply air to use.
The maximum air volume is 100L/min.
The characteristics of the digital temperature controller DAC-8EF are as follows:
Stable hot air temperature
It can be automatically adjusted throughout the entire temperature range.
Adopt a control method suitable for fast start air heaters.
Simply operate to set the air volume and temperature.
Various alarm outputs can notify customers of abnormal situations in their safety circuits.
When used in combination with SEN type air heater (with built-in temperature sensor), it is suitable for point heating applications that require precise temperature control, as shown in the following figure.
Preheating and final heating of solder (preheating is particularly effective for lead-free solder)
Deburring, cutting, and bending of resin and metal products
Drying of adhesives, inks, and paints
Bending of wound coils
glass processing
Other local heating applications

Before connecting the power input terminal, please ensure that the power cord is disconnected.
Ensure that the power switch of this device is turned off before connecting it to the terminal block.
Do not disassemble or modify this device.
We are not responsible for any malfunctions or accidents caused by customers' own modifications.
Incorrect wiring of this device may result in malfunctions or dangerous accidents. Before powering on, please check if the wiring is correct.
Please use within the rated specification range.
| 1 | Flow setting and display | 9 | 3) Sensor (thermocouple) input terminal (+) |
|---|---|---|---|
| 2 | Temperature setting and display | 4) Sensor (thermocouple) input terminal (-) | |
| 3 | Flow sensor power switch | 5) Event output terminal (COM) | |
| 4 | Temperature controller power switch | 6) Event output terminal (EV1) | |
| 5 | fuse | 7) Event output terminal (EV2) | |
| 6 | Fluid outlet (with a diameter of 8 pipes) | 8) External input terminal (RSW1) | |
| 7 | Fluid inlet (with a diameter of 8 distribution pipe) | 9) External input terminal (COM) | |
| 8 | Power input terminal | 10 | Flow sensor terminal |
| 9 | Temperature controller connection terminal | 10) Switch output terminal (+) | |
| 1) Heater output terminal | 11) Switching output terminal (-) | ||
| 2) Heater output terminal |
| power supply voltage | Communication 100V 50/60Hz | AC 200V 50/60Hz |
|---|---|---|
| Maximum load current | 10A | |
| Using a heater | Maximum study time | |
| temperature range | 0〜800℃ | |
| control method | Temperature controller: PID, flow rate: needle valve | |
| precision | Thermostat: ± 0.3% FS, flow rate: ± 3% FS | |
| Event output | Temperature controller: 2 event output points, flow rate: 1 event output point | |
| Contact rating | Thermostat: AC250V/DC30V 2A (resistant to load) | |
| Flow (switch output): NPN collector open circuit output (below 50mA, voltage drop below 2.4V) | ||
| external input | Temperature controller: external input number: 1, flow rate: none | |
| input format | Temperature controller: no voltage contact or open collector, flow rate: none | |
| Gas type | Air/nitrogen * injection 1 | |
| Flow control range | 3~100 liters per minute | |
| pressure resistance | 1 megapascal | |
| pressure range | 0-0.75MPa (standard pressure 0.3MPa) | |
| size | W161 × H119 (including rubber feet) × D200 (excluding terminal block) | |
| quality | About 2.6 kilograms | |
*For the purpose of improvement, specifications are subject to change without prior notice.
Note 1: The gas must be dry and free of corrosive substances (chlorine, sulfur, acid). The gas must be clean and free of dust and oil mist.
Note 2: If there is a possibility of foreign objects entering the equipment, please install filters, etc.
Note 3: When not using this product, please use a shut-off valve or other means to stop the gas supply.