- Phone
-
Address
2517, Building 4, Changxin Yue Plaza, Intersection of Huayuan East Road and Olympic West Road, Lixia District, Jinan City, Shandong Province
Shandong Knox Automation Technology Co., Ltd
2517, Building 4, Changxin Yue Plaza, Intersection of Huayuan East Road and Olympic West Road, Lixia District, Jinan City, Shandong Province
IMI Norgren safety valve
IMI Norgren, safety valve, XSz 8... XSz 50 series
Product Model:
2493230.0800.110.50
Order number:
2CGI1001
sales volume:
10
Sales status:
on sale
IMI Norgren safety valve
Technical parameters of stainless steel Dehailong HERION solenoid valve
2493230.0800.024.00
Main application scenarios: Single acting process execution mechanism
Based on IEC 61 508, DIN V 19 251
T Ü V certification. Certification: DIN EN 161/3394
DVGW, Rm group and EN 13611
Valves certified with SIL4 or AK7 safety systems
Standard NAMUR type integrated system, easy to install
Redundancy: 1oo2,2O3
Additional manual emergency control or inductive limit switch
Even in the event of a power failure, it can be mechanically returned
Type spring reset
The protection of electromagnetic coils complies with ATEX standards
Suitable for outdoor use under harsh environmental conditions (see reference)
Refer to the electromagnetic coil table)
Technical parameters of stainless steel Dehailong HERION solenoid valve
Technical Specifications
Medium:
Neutral or corrosive gases or liquids
Work pressure
0~10bar
flow to:
optional
Installation location:
Optional, it is recommended to install vertically.
Fluid temperature:
-25 ° C~+80 ° C NBR (rubber)
-10 ° C~+120 ° C FPM (fluororubber), water temperature
Degree Z is+95 ° C
-40 ° C~+60 ° C VMQ (silicone rubber)
When the temperature is below 0 ° C, please use dry air. When installed outdoors
To prevent moisture from seeping into the connection.
Please consult our technical department when using below+2 ° C.
Xxxx Insert the electromagnetic coil code according to the table below. *****Insert voltage code according to the table below
*The ambient temperature can reach as low as -40 ° C
**Certification is not included in the supply, part number 0695241.
#Gas or liquid fluid viscosity Z reaches 40mm2/s
The valve with T Ü V certification and installed in will be considered in the maintenance instruction document 7503444 based on safety standards DIN V 19250, IEC 61511.
The maintenance and repair of solenoid valves are the responsibility of the users or management agencies of these process systems.
Technical parameters of stainless steel Dehailong HERION solenoid valve