I80-2GX6GT Industrial Grade Gigabit 2-Optical 6-Electric TSN Synchronous Time Sensitive Switch

NegotiableUpdate on 05/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Supports 2 Gigabit SFP slots and 6 Gigabit RJ45 ports, providing users with flexible networking options; Support TSN time sensitive network series standards (IEEE802.1AS/Qbv/Qbu/CB/Qci), providing clock synchronization, low latency flow control, and reliability mechanisms; Support ring redundancy protocols such as KNEWlink Ring, ERPSv1/v2, STP/RSTP/MSTP, etc., to improve network reliability; ◆ Supports multiple power supply options, with DC dual power input voltage of DC9~60V, supporting dual power redundancy and non-polar connection; AC/DC single power input voltage AC85~264V or DC110~370V; ◆ Strong aluminum alloy shell, IP40 protection level, fanless shell for heat dissipation, equipment can reliably operate in harsh industrial environments ranging from -40 ℃ to+75 ℃

Product Details

overview

The I80-2GX6GT series is an 8-port full gigabit layer 2 network management card rail TSN industrial Ethernet switch from Shanghai Newlink Communication Technology Co., Ltd. It achieves reliable and deterministic low latency transmission of streams, supports 2 gigabit SFP slots and 6 gigabit electrical ports. Adopting a store and forward mechanism, it has powerful bandwidth processing capabilities, automatically checks packet errors, reduces transmission failures, and ensures stable, reliable, and efficient data transmission. The product selects industrial grade components, matched with high standard system design and production control, standard DIN card rail installation, aluminum alloy shell, sturdy and durable, fanless and efficient heat dissipation, wide temperature operation from -40 ℃ to+75 ℃, industrial protection design, able to adapt to various harsh working environments, and stable communication performance.

I80-2GX6GTThe series of switches follow the main communication standards in the industrial field, meeting technical issues such as real-time communication and network security. The product provides multiple ways to manage switches, such as accessing the switch command line (CLI) through CONSOLE port or TELNET/SSH protocol, accessing the switch web interface through HTTP/HTTPS, and accessing the device MIB through SNMP protocol. Simultaneously providing multiple network protocols and industry standards, such as TSN、PTP、ERPS、knewlink-Ring、STP/RSTP/MSTP、VLAN、QoS、LACP、IGMP Snooping、LLDP、802.1X、ACL、RMON、DHCPv4 Client/Server/Listening/Relay NTP、 Port mirroring, DDM, Ping, Traceroute, etc. Support system management such as uploading and downloading configuration files, upgrading and backing up image files online. In terms of structural installation, it is flexible to choose between rail mounted or wall mounted. The product is widely applicable in fields such as comprehensive energy, smart cities, rail transit, intelligent transportation, industrial automation, etc.

Support broadcast frame, multicast frame, and unknown frame storm suppression, support broadcast and multicast packet storm detection, and prevent network storms;

Supporting static and dynamic aggregation of LACP links can increase transmission bandwidth, improve link reliability, and achieve network load sharing;

Support 802.1Q VLAN, provide Access, Trunk, Hybrid interfaces for easy division into multiple broadcast domains, and enhance network security;

Support VLAN partitioning based on MAC, protocol, IP subnet, flow, and other methods, which can be applied to networks in different environments;

Support MAC address table and aging time limit, static unicast/multicast MAC address and interface binding to ensure the use of legitimate users;

Support PIM, IGMP, IGMP Snooping, and multicast filtering to reduce the broadcast of multicast data in the network and save network resources;

Support LLDP link layer discovery protocol, obtain LLDP neighbor device information, monitor link status, facilitate topology management and fault location;

Support ERPS Ethernet multi ring protection technology, provide multi ring networking, perform link backup, achieve fast convergence, and improve network stability;

Support VRRP virtual routing redundancy protocol, which combines multiple routing devices into a virtual router to achieve redundant backup;

Support multiple login methods such as HTTP, HTTPS, TELNET, SSH, CONSOLE port, etc;

Support SNMP v1/v2 c/v3, allowing for information retrieval, modification, and troubleshooting through the MIB network management system, achieving centralized management;

Support RMON remote network monitoring, perform statistics and alarms on various types of data frames, and can be used for remote monitoring and management of network management systems;

Support port security, convert dynamic MAC addresses into secure dynamic/static/Sticky MAC, and enhance device security;

Support 802.1X port authentication for authentication and access control of access users;

Support AAA secure network management mechanism, authenticate, authorize, and account through Radius and TACACS+to prevent unauthorized user login;

Support ACL access control list, customizable filtering rules for multiple frame types, filtering or rate limiting specified messages;

Support QoS service quality, prioritize the transmission of voice, video, and important data in network devices, and solve network congestion;

Support port mirroring, which can collect data sent and received by ports for network detection and fault management;

Support DDM digital diagnostic monitoring, which can monitor parameters such as operating temperature, voltage, current, and transmit/receive optical power of DDM SFP optical modules;

Support Ping IPv4/IPv6 and Traceroute IPv4/IPv6 to detect network connectivity and locate fault points;

Support dual power redundancy power failure alarm and port disconnection alarm, and support relay alarm mode;

Support DHCPv4 servers for centralized dynamic management and configuration of user IP addresses;

Support DHCPv4 listening to ensure that DHCP clients obtain IP addresses from legitimate DHCP servers, preventing DHCP attacks;

Support DHCPv4 relay to assist DHCP servers in dynamically allocating network parameters to DHCP clients;

Support system logging to record user operations, system security, system failures, and other information, and support remote monitoring of Syslog servers.

  • 时间敏感网络

    Time sensitive network

    Time Sensitive Networking (TSN) is a protocol standard developed by the IEEE802.1 TSN task force, which defines the time sensitive mechanism for Ethernet data transmission. By allowing some traffic packets to be forwarded first, using gate control scheduling mechanisms to clean up lines, and bandwidth reservation mechanisms to ensure the transmission performance of business traffic in Ethernet, it adds determinacy and reliability to standard Ethernet to ensure that Ethernet can provide stable and consistent service levels for the transmission of critical data. The currently supported time sensitive network basic protocols include: IEEE 802.1AS、IEEE 802.1Qbv、IEEE 802.1Qbu、IEEE 802.1CB、IEEE 802.1Qci、IEEE 802.1Qcc (Netconf/Yang) Wait.

  • 网管系统支持多种网络协议和行业标准

    The network management system supports multiple network protocols and industry standards

    The network management system supports multiple network protocols and industry standards, such as IPv6、PTP、TSN、RIP、OSPF、PIM、VRRP、ISIS、NAT、Ring、STP/RSTP/MSTP、MRP、ERPS、VLAN、IGMP/MLD、IGMP/MLD Snooping、DHCP Server/Relay、LLDP、LACP、 Port mirroring, etc; Having comprehensive management functions, supporting SNMP centralized management, port statistics, storm suppression, network diagnosis, online upgrades, etc; Supports CLI, HTTP, HTTPS, TELNET, SSH, Netconf and other access methods. The interface design of the network management system is friendly, easy to operate, and can bring you a good user experience.

  • 工业级直流冗余双电源

    Industrial grade DC redundant dual power supply

    The DC power supply consists of two independent power supply circuits, ensuring that the equipment can still operate normally in the event of a power failure in one circuit. The design of the dip switch enables the device to be reset to factory settings. When there is a link failure in the power supply or port, the ALM alarm light will highlight and sound an alarm, and the alarm device connected to the relay will also sound an alarm for quick troubleshooting on site. The hardware adopts fanless, low-power, and wide temperature design. Through strict testing in accordance with industry standards, it can adapt to industrial site environments with strict EMC requirements and can be widely used in industrial fields such as rail transit, smart cities, new energy, smart mining, and intelligent manufacturing.

Technical Parameter

FUNCTION

switching

Support 802.1Q VLAN, MAC/IP subnet/protocol/flow based VLAN, VLAN translation PVLAN

Support port configuration, such as port rate, duplex mode, flow control, maximum frame length, etc

Support port speed limit, storm suppression, storm detection, and port statistics

Support port aggregation, static aggregation, dynamic aggregation LACP

Support MAC address aging and learning restrictions, static MAC address binding

TSN

IEEE 802.1AS (generalized PTP gPTP)

IEEE 802.1Qbu (frame Preemption FP)

IEEE 802.1Qbv (Time-Aware Shaper TAS)

IEEE 802.1Qci (Per-Stream Filtering and Policing PSFP)

IEEE 802.1CB (frame Replication and Elimination for Reliability FRER)

Redundancy technology

Support Fast Loop Network (KNEWli)Nk Ring Private Protocol

Support ERPSv1/v2

Support STP/RSTP/MSTP

Support loop detection

multicast

Support IGMP Snooping

Support multicast filtering

safety management

Support HTTPS, SSH service control, HTTP/HTTPS, SNMP, TELNET/SSH access management

Support privilege levels and port security

Supports 802.1X port authentication, AAA authentication, as well as the Radius and TACACS+protocols

Support source IPv4/IPv6 protection and ARP protection

Support ACL and filter data from L2-L4 layers

Management and Maintenance

Supports IEEE 1588v2 (Precision Time Protocol PTP)

Support QoS, SP, DWRR queue scheduling

Supports DHCPv6 clients, DHCPv4 clients/servers/listeners/relays

Support SNMP v1/v2 c/v3, SNMP Trap v1/v2 c/v3, RMON, LLDP, LLDP MED

Support port mirroring DDM、Ping IPv4/IPv6、Traceroute IPv4/IPv6

Support user permission management, logging, NTP client, and daylight saving time

Support configuration file upload/download/activation/deletion, dual backup of images, restart, and factory reset

Exchange attributes

Exchange method

store and forward

backplane bandwidth

23Gbps

Cache size

1.25Mbit

MAC address table

8K

interface

Gigabit SFP

2-way 100/1000baSE-X adaptive gigabit SFP slot

Gigabit electrical port

Route 6, 10/100/1000baSe-T (X) adaptive gigabit RJ45 port, full/half duplex, MDI/MDI-X adaptive

relay

1 relay alarm output, 5.08mm spacing 3PIN terminal block

CONSOLE

1 CONSOLE port, RS232 signal RJ45 port, used for device debugging and command line configuration

key

One click factory reset

pilot lamp

Power indicator light, operation indicator light, alarm indicator light, optical port indicator light, TSN indicator light, Ring indicator light, electrical port speed and connection/activity indicator light

Power supply parameters

power input

I80-2GX6GT-D2:DC9~60V, Dual power redundancy, supporting non polarity;

I80-2GX6GT-LV: AC85~264V or DC110~370V

Full load power consumption

< 12W@DC24V

Connection method

5-position 5.08mm spacing terminal block

Power protection

Built in overcurrent protection

mechanical parameters

Physical dimensions

160 × 58 × 122 (mm) (excluding rail clamp)

Installation method

35mm standard DIN rail installation

Shell protection

IP40

weight

MISCOM7208TSN-2GF-6GT: approximately 0.86kg

MISCOM7208TSN-2GF-6GT-AD220: approximately 0.9kg

work environment

operation temperature

-40℃~75℃

storage temperature

-40℃~85℃

humidity

5%~95% (no condensation)

Industry standards

EMC

MISCOM7208TSN-2GF-6GT

IEC 61000-4-2(ESD):Level 4

Contact discharge point ± 8kV, air discharge ± 15kV

IEC 61000-4-5(Surge):Level 4

Power supply: Common mode ± 4kV, Differential mode ± 2kV Network port: Common mode ± 4kV, Differential mode ± 2kV

IEC 61000-4-4(EFT):Level 4

Power supply: ± 4kV Network port: ± 2kV

MISCOM7208TSN-2GF-6GT-AD220

IEC 61000-4-2(ESD):Level 4

Contact discharge point ± 8kV, air discharge ± 15kV

IEC 61000-4-5(Surge):Level 3

Power supply: Common mode ± 2kV, Differential mode ± 2kV Network port: Common mode ± 4kV, Differential mode ± 2kV

IEC 61000-4-4(EFT):Level 4

Power supply: ± 4kV Network port: ± 2kV


ordering information

standard model

Gigabit optical port

Gigabit electrical port

Power supply range

I80-2GX6GT-D2

2

6

Dual DC 9~60V

I80-2GX6GT-LV

2

6

AC85~264V or DC110~370V


Data Download

name