Overview
Hydrogen generator manufacturer: This hydrogen generator is equipped with two-stage overpressure protection, which reduces residual gas when stopped, and has an automatic shut-off function when power is cut off.
Product Details

Hydrogen generator manufacturer

Hydrogen generatorcharacteristic:

Fully automatic type, flow LED display, automatic tracking, simple operation, easy maintenance;

The gas and liquid paths are relatively good, with a gas-liquid separation device that can separate gas and liquid and automatically return the liquid to the electrolytic cell under pressure, solving the problem of liquid return;

Double electrolytic cells are connected in series and use microporous electrodes, with high electrolysis efficiency, stable performance during use, stable pressure and flow output, and no purity degradation;

Equipped with two-level overvoltage protection, there is less residual gas when it is stopped, and it has the function of automatically closing the gas circuit when power is cut off.

Instructions for using a hydrogen generator:

When using a high-purity hydrogen generator, the specific steps are as follows:

1. Open the packaging box, take out the high-purity hydrogen generator, check the appearance of the instrument, and verify the packing list.

2. Add electrolyte: Dilute and dissolve analytical pure potassium hydroxide with distilled water, cool it down, and inject it into the liquid tank through the inlet with a funnel. Then add distilled water to the liquid level near the mark.

3. Tighten the sealing cap on the hydrogen output port on the rear panel of the high-purity hydrogen generator.

4. Connect the power supply and check the grounding terminal of the instrument power cord to ensure it is grounded.

5. Start the high-purity hydrogen generator and observe the flow rate display (note: there may be fluctuations in the digital display of hydrogen production at the beginning of startup, which is a normal phenomenon).

6. The pressure gradually increases, and when the pressure reaches the set value, the digital display returns to zero and shows "000", indicating that the instrument is normal.

7. After starting up normally, turn off the machine first, then remove the sealing cap on the hydrogen outlet, connect it to the instrument through a pipeline, seal the joint, and then start the instrument until the pressure reaches the set pressure before use.