Horizontal furnace for fire resistance test of building componentsMainly used for evaluationFire resistance limit testing shall be conducted on coatings that can form a fire-resistant insulation protective layer on the surface of steel structures applied to buildings and structures to improve the fire resistance limit of steel structures.Used for testing fire-resistant components such as beams, slabs, and ceiling lights.
Horizontal furnace for fire resistance test of building componentsexecution standard
GB/T9978.1-2008 Fire resistance test method for building components
GB/T14907-2018 Fireproof Coatings for Steel Structures
GB/T9978.6.1-2008
GB/T9978.6.2-2008
GA/T714-2007 5.1.2
EN 13501-1:Fire classification of building products and components Part 1: Classification based on fire response test data
DIN 4102-1:Fire resistance performance of building materials and components Part 1: Classification levels for building material requirements and testing
NF P 92-501: French material flame retardant and fireproof testingMGrade determination - rigid materials(M0,M1,M2,M3,M4)
NF P 92-503: French material flame retardant and fireproof testingMGrade determination - flexible materials(M0,M1,M2,M3,M4)
BS 476:Fire retardant testing of building materials
GB/T51249-2017 Technical Code for Fire Protection of Steel Structures in Buildings
Technical specifications:
1. Furnace dimensions:4300 length * 3000 width * 1500 height mm;
2. Gas supply fuel:propane(Liquid phase bottle)LPG)Or natural gasLNG
3. Gasifier:500kg/h gasification capacity, power 54KW
4. Furnace wall temperature:<room temperature+45℃ ,Test maximum temperature:0~1360℃
5. Number of burners: on both sides15 units, a total of 30 units, with a total output power of 4500KW
6. Installation form of test piece: Inlaid
7. Combustion control form: proportional combustion1: 30. Furnace pressure PID control, temperature PID closed-loop control
8. Smoke exhaust form: The furnace smoke exhaust adopts lower smoke exhaust
9. Material of furnace sampling tube:USU310S High Temperature Resistant Stainless Steel Pipe(Furnace pressure sampling)
10. Differential pressure sensor:-200~200Pa, Full scale error ± 2Pa, in accordance with GB/T9978.1 regulations.
11. Furnace temperature sensor: Corundum thermocouple, temperature range0-1300℃
12. Test piece temperature measurement: copper sheet type,φ0.5mm, Diameter 12mm, back 0.2mm, temperature range: 0-600 ℃
13. Chamber exhaust fan: flow rate12734~17824m³/h, Full pressure 3208~2541pa, power 18.5KW
14. Combustion fan: flow rate3963~9600m³/h, Full pressure 4661~4256Pa, power: 18.5KW
15. Collector smoke exhaust fan:traffic3963~4792m³/h, Full pressure 4661~4256Pa, power: 11KW
16. Loading test piece: cross shaped nodeK-shaped node, total loading force of 1200KN, equipped with 4 loading cylinders, each outputting a force of 300KN, cylinder area: 253mm, pressure 20Mpa, servo proportional linear loading.
17. Load displacement:0-600mm, Precision of 0.01mm, equipped with 4 sets in total. Same as the loading cylinder.