- Phone
-
Address
1-1404-483, 14th Floor, No. 87 West Third Ring North Road, Haidian District, Beijing
Beijing Eurasia Depeng Technology Co., Ltd
1-1404-483, 14th Floor, No. 87 West Third Ring North Road, Haidian District, Beijing
Horizontal and Vertical Combustion Tester/Vertical Combustion Tester/Combustion Tester Model: DP-5
Horizontal and Vertical Combustion TesterSuitable working conditions and main technical indicators of the instrument
1. Environmental temperature: Room temperature to 40 ℃; Relative humidity: ≤ 75%;
2. Power supply voltage and power: 220V ± 10% 50HZ power 150W
3. Automatic ignition time of the lamp: arbitrarily set
4. Lamp inner diameter 9.5mm ± 0.5mm
5. Gas source: liquefied petroleum gas
6. Steel plate electrostatic spraying box
7. More than 0.5 cubic meters (steel plate electrostatic spraying version)
8. Instrument weight approximately: 100kg
9. Working power supply: 220V AC 50HZ
10. Timing range: 0~999s Timing accuracy: 10s ± 0.2s 30s ± 0.2s;
11. Flame application time: 0-99.9S (adjustable)
12. Residual flame time: 0-99.9S (adjustable)
13. Remaining burning time: 0-99.9S (adjustable)
14. Combustion angle: 0 °, 20 °, 45 ° can be selected
15. Flame height: adjustable from 20mm to 175mm
16. Flame temperature: (100-1000) ℃ adjustable
17. Gas flow rate: adjustable from 105ml/min to 1000ml/min
18. Combustion lamp: inner diameter of lamp tube 9.5 ± 0.3mm, length: 100mm ± 10mm
19. Time device: can be accurate to 0.5S
20. Position adjustment: the sample holder bracket can be adjusted up and down, left and right, the combustion seat can be adjusted back and forth, and the adjustment stroke is large
21. Dimensions: Width 1160mm, Depth 600mm, Height 1310 (including feet) mm
22. Combustion test area volume:>0.5 cubic meters, length * width * height approximately 900mm × 590mm × 1050mm, background black, background illumination ≤ 20Lux
Dark box type three purpose UV analyzer/three purpose UV analyzer/UV analyzer model: DP-203B
1、 Principle
This instrument is composed of ultraviolet lamps and filters. It can emit 253.7nm and 365.0nm ultraviolet rays separately, and can also mix and use two wavelengths at once.
Main technical indicators
Wavelength: 253.7nm, 365.0nm
Color filter: 150 × 50 (mm)
Dimensions: 300 × 300 × 270 (mm)
Large irradiation area: 250 × 250 (mm) (usable area)
Power supply: AC220V ± 10% 50HZ
Weight: 3Kg
Desktop Three Frequency CNC Ultrasonic Cleaner/Three Frequency CNC Ultrasonic Cleaner Model: DP-300VDE
Main technical indicators
model |
Instrument size (mm) |
Size inside the cleaning tank (mm) |
capacity (L) |
ultrasound frequency (KHz) |
frequency conversion Adjustable time (S) |
ultrasound power (W) |
power adjustable (%) |
water ingress liquid level (mm) |
heat power (W) |
temperature adjustable (℃) |
time adjustable (min) |
drop sound cover |
enter row water |
|||
DP-300VDB |
320*264*320 |
300*240*150 |
10 |
45 |
80 |
100 |
1-999 |
300 |
40-100 |
1-120 |
400 |
10-80 |
1-480 |
Nothing |
manual control |
|
DP-300VDE |
320*264*340 |
300*240*150 |
10 |
45 |
80 |
100 |
1-999 |
300 |
40-100 |
1-120 |
400 |
10-80 |
1-480 |
have |
manual control |
|
DP- 300VDV |
410*350*380 |
300*240*180 |
13 |
45 |
80 |
100 |
1-999 |
300 |
40-100 |
1-140 |
400 |
10-80 |
1-480 |
have |
electric control |
|
Steel bar detector/steel bar position detector model: DP-180
Product features:
Measure the thickness of the concrete protective layer
Position the steel reinforcement
Estimate the diameter of steel bars
Main technical indicators:
1. Measurement range of protective layer thickness (nominal):
Range (nominal): 6mm to 90mm
Two range (nominal) range: 7mm~200mm
2. Measurement range of steel bar diameter (nominal): Ø 6 to Ø 50mm
3. The measurement value of the thickness of the steel reinforcement protective layer has a large allowable error:
Maximum allowable error (mm) Protection layer range Protection layer range
≤±1 6~59 7~79
≤±2 60~69 80~119
≤±4 70~90 120~200
4. Large allowable error range for measuring the diameter of steel bars: ± 1 level
5. Normal working environment requirements:
Working temperature: -10 ℃ to+40 ℃
Relative humidity:<90% RH
Ultrasonic level gauge Model: DP-RPF
Main functional features:
·Distance accuracy online calibration can be performed in different environments, and the range start and end points, output analog type, and liquid level window lock values can all be set with a keyboard.
Main technical indicators: (Models other than the following parameters can be customized)
Product Model DP-RPF
Range 5m, 10m, 15m
Detection blind zone ≤ 400~800mm (depending on the range and sensor)
Detection accuracy of 0.25~0.5% F.S (at 25 ℃, beyond blind spot range, calm target surface)
Output signal 4-20mA two-wire system, three wire system, four wire system; 0~20mA
1~5V,0~5V
RS485,RS232;
1-4 switch signals, 1-4 relay outputs
(Default 4-20mA three wire system, other output methods can be customized)
Display mode LCD; LED (two-wire system only displays four liquid levels on LCD, choose any other option)
Working temperature range of 0~50 ℃ (default, customizable for a wider temperature range)
Working power supply DC24V/300mA (default, customizable AC220V/50hz, or DC wide voltage supply)
Outgoing method: quick connect terminal block
Installation method: Threaded installation, thread size M68 × 2.0