The RAEGuard Lite series FGM-7100 is a safe and reliable gas detection smart choice carefully crafted for customers based on Honeywell's latest fixed product design concept. The RAEGuard Lite series adopts an intelligent modular design, consisting of a transmitter and optional * * gas, $r $n $r $n toxic gas, and oxygen sensors. It can be applied in indoor and outdoor hazardous environments to monitor the degree of danger of hazardous gases in real time, quickly and effectively protecting the safety of installation sites and production personnel.
RAEGuard Lite seriesFGM-7100It is adoptedHoneywellThe design concept of the latest fixed product is carefully crafted as a safe and reliable gas detection smart choice for customers.RAEGuard Lite seriesAdopting intelligent modular design, consisting of transmitters and optional * * gases
Composed of toxic gas and oxygen sensors, it can be applied in indoor and outdoor hazardous environments to monitor the degree of danger of hazardous gases in real-time, quickly and effectively protecting the safety of installation sites and production personnel.
RAEGuard LiteEquipped with a large LCD display screen, supporting industrial standard 3-wire analog current output and Modbus RTU digital signal output.Honeywell RAEGuard Lite * */Toxic Gas DetectorAdopting high anti poisoning catalytic combustion technologyToxic and Oxygen
detectionApplying various compensatory electrochemical techniques to enhance the performance of sensors. especiallyOxygen detectorZero point (nitrogen) calibration can be avoided, and with the overall explosion-proof structure design, it can be widely used in various detection environments.

FGM-7100Main features: Safe and reliable • Anti poisoning * * gas detector and excellent toxic gas/oxygen sensor technology • Wide temperature and environmental factor compensation make the instrument always reliable and stable • Redundant design ensures no "false alarm" • Clear status indication and optional sound and light alarm, timely perception of environmental danger level • Optional built-in lightning protection module for worry free outdoor installation • IP66; SIL2 * Easy to install and operate • Only requires the built-in U-shaped clamp for installation • Integrated backplane and housing, easy to install • Plug and unplug wiring terminals for easy wiring • Adjustable Chinese and English display • Large dot matrix backlit LCD display • 3 high brightness LED status indicators • Diversified output with column shaped concentration graphics, digital display, and easily recognizable icons • Adjustable standard three wire source current output to avoid signal distortion caused by wiring • RS485 Modbus digital signal for multi-point networking and remote real-time monitoring • Bluetooth remote easy operation * • Optional standard HART ® Communication protocol for remote diagnosis and setup * Lower operating and maintenance costs • Automatic recognition sensor module • One detector with multiple detection ranges that can be set by oneself • Non invasive magnetic rod operation for configuration/calibration/testing functions • Intelligent warning prompts and fault diagnosis reminders • No need for hot work permits
Technical specifications
| Detection Principle |
catalytic combustion type |
| model |
GTYQ-FGM-7100(**气) |
| sampling method |
Diffusion type |
| working power supply |
24VDC (normal operating voltage range: 16-32VDC) |
| Typical power |
Electrochemical<1W; Catalytic combustion 2W (maximum 5W) |
| output signal |
Standard configurable (source type), optional HART ® 7.2 Agreement* |
| load impedance |
600Ω |
| Other outputs** |
RS485, Modbus RTU
Optional 3 relays (30VDC 5A); Optional Bluetooth *; Hart
|
| protection level |
IP66 |
| connection |
2 3/4 NPT on-site inlet ports, 1 M25 sensor connector |
| terminal block |
5 wiring terminals (11 for models with relay output); Wire diameter: 0.5mm2 (20AWG) to 2.5mm2 (13AWG) |
| Installation method |
Wall or pipe installation |
| display mode |
Ultra large dot matrix LCD display 3 LED status and function indicator lights
|
| Working temperature*** |
-40 ℃ ~+70℃ |
| Operating Humidity |
LEL: 0~95% RH (no condensation); |
| work pressure |
90 ~ 110kPa |
| Overall dimensions |
176mm×157mm×118.5mm(HWD) |
| Material of transmitter |
aluminum alloy |
| sensor material |
316 stainless steel |
| weight |
Aluminum alloy: approximately 2.3kg |
| China |
Explosion proof certification:
LEL:Ex db IIC T6 Gb Ex tb IIIC T80℃
Ex db IIC T5 Gb Ex tb IIIC T90℃
EC:Ex db IIC T6 Gb Ex tb IIIC T80℃
• Metrological certification: CPA
|
| Lightning protection performance |
Surge optional (lightning protection module): anti-interference level 4
Compliant with GB/T17626.5-2008/IEC61000-4-5.2005
|

Technical parameter detection principle Catalytic combustion/electrochemical models GTYQ-FGM-7100 (* * gas), GTYQ-FGM-7300 (toxic gases and oxygen) Sampling method Diffusion working power supply 24VDC (normal operating voltage range: 16-32VDC) Typical power Electrochemical<1W; Catalytic combustion 2W (maximum 5W) Output signal Standard configurable (source type), optional HART ® 7.2 Protocol * Load impedance 600 Ω Other outputs * * RS485, Modbus RTU optional 3 relays (30VDC 5A); Optional Bluetooth *; Hart protection level IP66 connector with 2 3/4 NPT on-site inlet interfaces, 1 M25 sensor connector with 5 terminal blocks (11 for models with relay output); Wire diameter: 0.5mm2 (20AWG) to 2.5mm2 (13AWG) Installation method Wall or pipeline installation Display method Large dot matrix LCD display 3 LED status and function indicators Working temperature * * -40 ℃~+70 ℃ Working humidity LEL: 0~95% RH (no condensation); Toxic gases and oxygen: 15%~95% RH (no condensation) working pressure 90-110kPa external dimensions 176mm × 157mm × 118.5mm (HWD) transmitter material aluminum alloy sensor material 316 stainless steel weight aluminum alloy: about 2.3kg China • Explosion proof certification: LEL: Ex db IIC T6 Gb Ex tb IIIC T80 ℃ Ex db IIC T5 Gb Ex tb IIIC T90 ℃ EC: Ex db IIC T6 Gb Ex tb IIIC T80 ℃ • Measurement certification: CPA lightning protection performance surge optional (lightning protection module): anti-interference level 4 in accordance with GB/T17626.5-2008/IEC61000-4-5.2005 Remarks: * Not yet released, please stay tuned * * RAEGuard Lite Future We will also provide users with more diverse communication interfaces and gas types, such as wireless. Please contact the relevant sales personnel for availability. ***The gas sensor can operate continuously from -40 ℃ to+70 ℃; The toxic gas and oxygen sensors can operate continuously from -20 ℃ to+55 ℃, and intermittently from 40 ℃ to+70 ℃ (the accuracy and response time of sensors operating in this temperature range may be affected, and long-term operation may lead to a decrease in sensor sensitivity or even damage). The above product performance characteristics are typical results tested in an environment with a temperature of+20 ℃ and a temperature of 50% RH. When calibrating, please use a calibration cover and the recommended flow rate for testing. If a sunshade is used or in low temperature environments, the response speed will be slowed down. Standard configuration • Detector host • Quick operation guide • Calibration cap • Z-tool • U-shaped clamp • Rain cover • Plug optional accessories • Gas collection cover • Sun visor • Cable gland • Quick installation kit • Gas sampling cover • Relay module • Lightning protection module • HART module (not yet available) • Sound and light alarm • Bluetooth module (not yet available) • Magnetic rod
Technical parameter detection principle Catalytic combustion/electrochemical models GTYQ-FGM-7100 (* * gas), GTYQ-FGM-7300 (toxic gases and oxygen) Sampling method Diffusion working power supply 24VDC (normal operating voltage range: 16-32VDC) Typical power Electrochemical<1W; Catalytic combustion 2W (maximum 5W) Output signal Standard configurable (source type), optional HART ® 7.2 Protocol * Load impedance 600 Ω Other outputs * * RS485, Modbus RTU optional 3 relays (30VDC 5A); Optional Bluetooth *; Hart protection level IP66 connector with 2 3/4 NPT on-site inlet interfaces, 1 M25 sensor connector with 5 terminal blocks (11 for models with relay output); Wire diameter: 0.5mm2 (20AWG) to 2.5mm2 (13AWG) Installation method Wall or pipeline installation Display method Large dot matrix LCD display 3 LED status and function indicators Working temperature * * -40 ℃~+70 ℃ Working humidity LEL: 0~95% RH (no condensation); Toxic gases and oxygen: 15%~95% RH (no condensation) working pressure 90-110kPa external dimensions 176mm × 157mm × 118.5mm (HWD) transmitter material aluminum alloy sensor material 316 stainless steel weight aluminum alloy: about 2.3kg China • Explosion proof certification: LEL: Ex db IIC T6 Gb Ex tb IIIC T80 ℃ Ex db IIC T5 Gb Ex tb IIIC T90 ℃ EC: Ex db IIC T6 Gb Ex tb IIIC T80 ℃ • Measurement certification: CPA lightning protection performance surge optional (lightning protection module): anti-interference level 4 in accordance with GB/T17626.5-2008/IEC61000-4-5.2005