- Phone
-
Address
No. 6, Lane 1118, Jintong Road, Putuo District, Shanghai
Shanghai Kangdeng Electric Technology Co., Ltd
No. 6, Lane 1118, Jintong Road, Putuo District, Shanghai
TAG8000High voltage wireless phase detector
This product is an ideal nuclear phase instrument that is safe, reliable, stable in performance, and easy to operate.
TAG8000High voltage wireless phase detectorInstrument features:
Screen display content: wireless high-voltage nuclear phase analyzer, different phases, same phase X、Y 、
Power supply: One battery (NEDA/604/6F22) or equivalent model for the host. 5 AG13 batteries for X and Y collectors.
Automatic shutdown: The host automatically shuts down after about 15 minutes of startup.
Backlight source: During the phase detection process, if the light is too dim, making it difficult to read data, you can press the backlight switch.
Technical Specifications:
Voltage level: 0.38kV~500kV
Host power supply: 9V ± 2V
Collector power supply: 7.5V ± 1.5V
The line of sight transmission distance between the host and the X and Y collectors is: X ≥ 80m Y ≥ 50m
Working environment: -35 ℃~+50 ℃ ≤ 95% RH humidity:
Storage environment: -40 ℃~+55 ℃ ≤ 95% RH humidity:
Insulated telescopic rod: 600mm in the contracted state and 3200mm in the extended state
Packaging box dimensions (length x width x height): 650mm x 250mm x 100mm
Product total weight: 5kg

2、 Product features:
In the nuclear phase, there is voltage regardless of whether the phases are the same.
2. 220V low voltage can be used to check whether the nuclear phase instrument is normal.
3. The high-voltage nuclear phase meter is equipped with an automatic power switch inside, which automatically turns on the power when in use and turns off when not in use, making it convenient and energy-saving.
3、 Usage:
1. Self check and identify whether the phase instrument is in good condition.
First, insert the test line into the instrument socket, and then plug the other end into a 220V power supply. At this point, there are three reactions as described in Table 4. If there are three reactions, it indicates that it is good. If there are no three reactions, it indicates that there is a problem and it cannot be used.
2. Use a multimeter to check if the high-voltage connection is conducting.
3. Test header items:
If the above method detects that the nuclear phase instrument is normal, then the nuclear phase can be officially verified. If it is already known that the nuclear phase instrument is normal, it can be used directly without testing. If there is no voltage display during the inspection, it indicates that the battery voltage is insufficient and the battery should be replaced. You can open the instrument casing and replace it with a new 9V stacked battery. Note: When the battery voltage is below 6V, there is no sound prompt. As long as the voltage is not lower than 4.5V, it can be displayed correctly.
4. Connect the high-voltage connection as shown in the following diagram:

5. Prediction of Nuclear Phaser:
Before the formal nuclear phase, the nuclear phase detector can be checked for good condition in the same power grid system. One person contacts the A rod with one of the conductors, while the other person contacts the B rod with each conductor in the same power grid. According to Table 4, there are three reactions in different phases, while there are no three reactions in the same phase. Then we can officially establish the nuclear phase.
6. Formal operation:
The nuclear phase operation should be carried out by three people, with two people operating and one person supervising. It must be operated one by one,
Record one by one and determine whether the phase is correct based on the "three haves and three noes" described in Table 4. The nuclear phase operation should be carried out conscientiously in accordance with the regulations and systems formulated by our unit.
7. Maintain safety:
During operation, the human body must not come into contact with nuclear phase instruments, high-voltage connections, and grounding wires, and must maintain a safe distance.
Line Nuclear Phase TesterHigh voltage phase analyzer, wireless phase analyzer,Line Nuclear Phase TesterHigh voltage phase analyzer, wireless phase analyzer,Line Nuclear Phase TesterHigh voltage phase analyzer, wireless phase analyzer
4、 Instrument completeness:
1. Insulation rod
2. Test one header
3. Test one set of connections
4. Self configuration of grounding wire
5. One self checking plug
6. One copy of the instruction manual
7. One warranty card
After sales service commitment
1. Service tenet: Quick response, appropriate handling, and thoughtful service.
2. Service objective: Customer satisfaction is our goal.
3. Service principle: The free warranty period for the product is one year. During the warranty period, the supplier will provide free repair and replacement of parts damaged due to quality reasons. For parts damaged outside the warranty period, only the cost fee will be charged for the provided parts. For equipment damage caused by human factors of the purchaser, the supplier's repair or provided parts will be calculated at cost price.
Our philosophy is "integrity-based, strength first, wholeheartedly for customers". The company adheres to the business philosophy of customer first and service first, and guarantees customers to gallop on the high-speed road of the information age with our service quality, professional technical service strength, and technical customer service team. With the spirit of stability, development, loyalty, efficiency, unity, and innovation, we respect talents and pay attention to technology, so that customers can continuously obtain large profits while enjoying the achievements of information technology development.