- Phone
-
Address
No. 607, Building 1, Huihuang International, Shangdi 10th Street, Haidian District, Beijing
Beishide Instrument Technology (Beijing) Co., Ltd
No. 607, Building 1, Huihuang International, Shangdi 10th Street, Haidian District, Beijing
BSD-660 Fully Automatic High ThroughputHigh performance specific surface area and pore size analyzer for combustible gas adsorption
Product Overview:
Analysis of specific surface area and mesopores, micropores, and ultramicropores
High throughput analysis: up to 12 samples can be analyzed simultaneously
◆ Truly fully automatic: degassing test, fully automatic switching, no need for human intervention
Main Function
High throughput rapid specific surface area analysis;
◆ Pore volume and pore size distribution (mesoporous, microporous, ultramicroporous)
Conventional gas adsorption, such as N2, O2, Ar, CO, CO2, etc
◆ Adsorption of combustible gases, such as H2, CH4, C2H6 and other alkynes;
High performance specific surface area and pore size analyzer for combustible gas adsorption
Technical Parameters
Wide testing range: specific surface area above 0.0005 ㎡/g, pore size 0.35-500nm;
High testing accuracy: specific surface area, pore size, pore volume, adsorption capacity ≤ 1% RSD (standard sample);
◆ Program heating and degassing: Software controlled program heating, room temperature -400 ℃, accuracy better than 0.1 ℃;
Intelligent degassing completion judgment: supports software automatic judgment, automatically judges the degassing effect based on pressure changes;
◆ Anti flying degassing: "Program controlled pressure"+"Program controlled temperature"+"Degassing furnace lifting"="Pressure controlled temperature rise";
Vacuum degree: 10-2Pa, optional molecular pump, vacuum degree can reach 10-8Pa;
Technical Advantages
◆ High throughput: Supports analysis of up to 12 samples at a time;
◆ Fully automated: The international degassing furnace and Dewar cup switch automatically, without the need for manual transfer of sample tubes or degassing furnaces;
High time utilization rate: It solves the problem of wasting time when conventional instruments cannot start testing after degassing is completed after work, making it a reality to install samples after work and check data at work;
Eliminate "helium pollution": Helium testing dead volume vacuum heating degassing adsorption testing solves the problem of helium pollution in microporous analysis internationally and improves testing accuracy;
◆ Anti flying degassing: Supports "programmed pressure control" and "programmed temperature control" degassing, automatically raising and lowering the degassing furnace according to pressure changes to prevent sample flying;
◆ Support automatic cycle testing: automatic degassing+test cycle testing, used to evaluate the stability and lifespan of material adsorption performance;
◆ "Pressure controlled heating" anti flying degassing technology;
◆ "Automatic constant temperature zone" technology;
◆ Convenient installation and sealing: The one-time sealing technology for 6 sample tubes in a single analysis station eliminates the need to seal each tube individually, providing an efficient experience;
◆ Full temperature control of the pneumatic system: The internal pneumatic system of the instrument is fully temperature controlled to 40 ℃, with an accuracy better than 0.1 ℃;
◆ Upward sliding door: Humanized and easy to open and close, saving laboratory space;
◆ Electric turbine liquid nitrogen pump: Humanized liquid nitrogen addition, stepless speed regulation, free movement, safe and convenient, liquid nitrogen pollution-free;
◆ High reliability: International supplier system, all core components are adopted;
