- Phone
-
Address
Room 3-1510, Shilin Central City, No. 99 Wangqiao Road, Liuhe District, Nanjing City, Jiangsu Province
Nanjing Yiyucheng Instrument Co., Ltd
Room 3-1510, Shilin Central City, No. 99 Wangqiao Road, Liuhe District, Nanjing City, Jiangsu Province
High frequency carbon sulfur analyzerAnalysis scope:
High frequency induction furnace (500mg sample): Low carbon: 1ppm~0.1% High carbon: 0.1%~5%
Low sulfur: 1ppm~0.3%
Note: Changing the sample size can expand the analysis range
Analysis accuracy:
High frequency induction furnace: Low carbon: 1ppm or RSD ≤ 1% High carbon: RSD ≤ 0.5%
Low sulfur: 1.5ppm or RSD ≤ 1.5%
Sensitivity:
0.01ppm
2.4 Analysis time
30 seconds to 40 seconds
High frequency carbon sulfur analyzerInstrument structure:
Modular structure, consisting of high-frequency induction furnace host, computer, vacuum cleaner, printer *, electronic balance * and other modules
Note: * is an optional accessory
Sample weighing:
Recommended range: 0.1g to 0.5g, the sample size can be adjusted according to the sample content
Combustion furnace:
High frequency induction furnace: 18MHz 2.7KVA. The combustion chamber of the high-frequency furnace can be automatically cleaned during each analysis process, making it easy to maintain on a daily basis
Sulfur and nitrogen analyzer infrared detection system:
Standard configuration: The carbon sulfur analyzer is equipped with three independent infrared absorption cells (i.e. three physical channels: 2 carbon channels and 1 sulfur channel), which can be combined with high carbon/low carbon/high sulfur/low sulfur channels according to customer needs, but the total number of channels does not exceed three
Detector: Adopting a German imported pyroelectric solid-state infrared detector
Motor: Adopting Swiss imported synchronous motor
Light source: Adopting American imported antioxidant and stable infrared light source
Constant temperature: The entire chamber is controlled at a constant temperature to ensure constant analysis gas temperature and measurement accuracy
Carrier gas: The infrared light source and detector are protected and purified with oxygen, isolating the influence of the surrounding environmental atmosphere and improving stability and measurement accuracy
Correction (two methods):
Single point calibration: calibrate with a single analysis result
Multi point correction: using multiple analysis results for correction
Flow control:
Analyze the airflow using high-precision electronic flow control technology
Environmental protection measures:
High frequency shielding
Dust filtration:
Adopting imported specialized metal dust filter screen, easy to disassemble and easy to clean
Instrument self-test function:
Automatic monitoring and alarm of high-frequency furnace switch
Reset automatic monitoring and alarm of high-frequency furnace cleaning device
The software provides a step-by-step self-test function (monitoring and adjusting infrared signals, checking the actions of various valves in the air circuit)
The instrument can achieve segmented leak detection through software
Power Supply:
220VAC ±10% ,50 ±1Hz, 16A
Appearance
Width 55cm, height 77cm, thickness 76cm
Weight:
100kg
Software functions:
Steel Research Nak Company provides users with software in the Windows environment, which features *, is easy to operate, flexible to use, and has a friendly interface
Data display and storage
Quickly display the results and analysis curves of the analysis
Automatic storage of analysis results
Drawing and Storage of Dynamic Release Curve
Weight input:
The instrument can automatically read the weight of the sample and the weight of the flux, and automatically complete the peeling function
Channel switching:
Automatic switching between high and low carbon channels and high and low sulfur channels
Data processing:
Multi mode queries can be performed on stored data, such as querying by date or sample number
Can filter data
Perform statistical processing on data (mean, standard deviation, relative deviation)
Perform signal comparison on the release curve of the analysis results
Parameter settings:
Flexible adjustments can be made to analysis parameters such as flushing time, analysis time, and flux blank based on specific samples
Corresponding calibration methods and parameters can be established for different types of samples and stored in the database, with no limit on the number of analysis methods
Instrument automatic function:
Automatic alarm when an error occurs
High frequency furnace automatically cleans twice per analysis
After each analysis, the instrument automatically blows back the dust filter
Automatic vacuum cleaning after analysis
Laboratory installation requirements:
Oxygen: purity greater than 99.5%
Nitrogen: Industrial grade
Power supply: 220VAC ± 10%, 50 ± 1Hz, minimum current 16A (recommended to configure single-phase 5KVA stabilized power supply)
Applicable temperature: 18 ° C to 29 ° C
Applicable humidity:<80% RH
Grounding resistance:<5W
No electromagnetic interference, no strong electromagnetic field, no strong vibration
Placement table: Length x Width x Height: 150cm x 80cm x 80cm (Users can choose a universal table, only for placing computers, printers, and electronic scales, requiring these two tables to be 50cm away from the wall)
Experimental bench: with a load-bearing capacity greater than 150Kg (only for placing the instrument host)