Overview
High Pressure Reducing Valve (HPRV) is suitable for analysis, discharge, and sampling scenarios of high-pressure steam/water systems, especially in industrial scenarios that require high temperature and high pressure tolerance, avoidance of blockage, and stable flow and pressure. Its application effect is significant
Product Details

High Pressure Reducing Valve


application

  • Steam and water analysis system

  • Boiler water discharge system

  • sampler


benefit

  • avoid obstacles

  • Higher flow velocity

  • Compliant with ASME-PTC 19.11.


feature

  • Design of Pipe Rod

  • Designed for high pressure up to 350 (5076 PSI) barg

  • Design temperature: 150 ° C (302 º F)

  • The outlet pressure ranges from 1 to 20 barg. (14.5 to 290 pounds per square inch)


1、 Core application scenarios (clearly adapted system)

The design scenario of this long high-pressure pressure reducing valve is highly focused onPressure control and sampling/discharge requirements for high-pressure fluid systemsThe core application areas clearly marked include:

  1. Steam&Water Analysis Systems (SWAS)

    • Function: In the process of analyzing the composition of steam and water, the high-pressure fluid in the system (such as high-pressure steam generated by boilers and circulating water) is stably depressurized to the low-pressure range (1-20 barg) that subsequent analysis equipment (such as sensors and detectors) can withstand, avoiding damage to precision analysis components caused by high pressure, while ensuring stable fluid flow and accurate analysis data.

    • Adaptability: The analysis system has high requirements for fluid pressure stability and cleanliness. The "non clogging" characteristic of this valve can avoid impurities affecting the analysis results, making it suitable for such high-precision scenarios.

  2. Boiler water blowdown systems

    • Function: During boiler operation, it is necessary to regularly discharge some high-temperature and high-pressure boiler water (to remove scale and impurities and ensure water quality standards). This valve can safely reduce the pressure of high-pressure (up to 350 barg) and high-temperature (up to 150 ℃) water in the boiler, prevent impact on pipelines or equipment during high-pressure discharge, reduce safety risks, and control the discharge flow rate to avoid water resource waste.

    • Adaptability: Boiler discharge needs to withstand high temperature and high pressure conditions. The design pressure (350 barg) and temperature (150 ℃) of this valve are perfectly matched, and the "high flow" characteristic can meet the discharge efficiency requirements.

  3. Grab Sampling Systems

    • Function: In the manual sampling process of industrial fluids such as process water, steam, and chemical media, the high-pressure fluid is depressurized to a safe and easy to operate pressure range, making it convenient for workers to use the sampler to collect samples, while avoiding fluid splashing caused by high pressure during the sampling process, ensuring operational safety.

    • Adaptability: The sampling scenario requires flexible adjustment of the outlet pressure (adjustable from 1-20 barg), and the "Rod In Tube Design" can reduce fluid retention and ensure the representativeness of the sampling sample.

2、 What application is good ": the core judgment criterion for adapting to scenarios

Combined with the pressure reducing valveCharacteristics (high voltage tolerance, no blockage, high flow rate, ASME-PTC 19.11 standard)andadvantageThe following scenarios have excellent performance:

Key features of adaptation scenarios Advantages and support of corresponding valves Typical scenario examples
High system inlet pressure (≤ 350 barg) Design pressure up to 350 barg, directly compatible with high-pressure sources High pressure boiler, high-pressure steam pipeline network
The fluid needs to be stably depressurized to low pressure (1-20 barg) The export pressure is precisely adjustable to meet the low-pressure requirements of downstream equipment Analytical instruments, samplers, low-pressure pipelines
Need to avoid fluid blockage (containing small amounts of impurities) 'Avoid obstructions' design to reduce blockages Boiler discharge (including scale), industrial circulating water
High traffic required (to ensure efficiency) High flow rate feature Large diameter sewage pipeline, batch sampling system
Must comply with industry standards (ensuring safety) Follow ASME-PTC 19.11 standard (Fluid Measurement and Control Standard) Industries with high compliance requirements such as chemical and power industries

3、 Supplementary Information (Assisting in Application Selection)

  • Key technical parametersEnsure that the application scenario matches the following parameters to avoid out of range use

    • Maximum inlet pressure: 350 barg (5076 PSI)

    • Maximum operating temperature: 150 ℃ (302 ℉)

    • Export pressure range: 1-20 barg (14.5-290 PSI)


Overall, this long high-pressure pressure reducing valve (HPRV) is suitable forAnalysis, Discharge, and Sampling Scenarios of High Pressure Steam/Water SystemsEspecially in industrial scenarios that require tolerance to high temperatures and pressures, avoidance of blockages, and ensuring stable flow and pressure, the application effect is significant.


High Pressure Reducing Valve

Part Number
model
Component Name
operation
HPRV
HPRV
High pressure reducing valve