Heavy oil heat testing instrument

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Heavy oil heat testing instrument, computer-controlled automatic calibration of instrument heat capacity, automatic calculation and conversion of high and low heat generation, automatic storage and printing of results. Low failure rate, self-protection, self diagnosis, and easy daily maintenance for customers. Easy to operate and accurate results.

Product Details

heavy oilThermal testing instrument
HKRL-5000 modelheavy oilThermal testing instrumentThe computer controls the automatic calibration of the instrument's heat capacity, automatically calculates and converts the high and low levels of heat generation, automatically saves and prints the results. Low failure rate, self-protection, self diagnosis, and easy daily maintenance for customers. Easy to operate and accurate results. Used to determine the calorific value of liquid fuels such as liquid oil, heavy oil, crude oil, light oil, kerosene, wax oil, gasoline and diesel, methanol and ethanol, synthetic oil, bio oil, gutter oil, fuel oil, acetone, blended oil, etc.
Technical Specifications:
Temperature measurement range: 5-40 ℃ (temperature change should be ≤ 1 ℃ per measurement)
Relative humidity: ≤ 85%
Temperature resolution: 0.0001 ℃
Precision: ≤ 0.1%
Test time: Balance the water temperature for 7 minutes during the initial ignition stage, test the main temperature for 8 minutes after ignition, and conduct the entire experiment for about 15 minutes.
Power: 500W
Power supply: 220V ± 10V
Measurement accuracy: in accordance with the national standard GB/T213-2008
Outer bucket capacity: 40L
内桶容量: 2.5L
Ignition voltage: 24V
Performance characteristics:
1. The computer controls the automatic calibration of the instrument's heat capacity, automatically calculates and converts the high and low levels of heat generation, automatically saves and prints the results.
2. Low failure rate, self-protection, self diagnosis, and easy daily maintenance for customers.
3. At the same time, the instrument adopts a unique cooling calibration system, which can ensure the stability of test results for a long time;

4. Easy to operate and accurate results. It has functions such as data modification, tabulation, and management.


When is it necessary to recalibrate the capacity

1. Due to the varying temperature values (relative temperature values) measured by each temperature probe, their linearity is also differentConsistent, therefore, when replacing the temperature probe, the thermal capacity of the calorimeter needs to be recalibrated.
When calibrating heat capacity and measuring heat generation, if the room temperature differs by more than 5 ℃, the heat capacity should be recalibrated (although platinum resistors have good linearity within a certain temperature range, they do not need to be calibrated with average division values when working within the specified temperature range, otherwise it will cause significant errors that cannot be ignored).