Ideal laboratory instruments
Easy to use and operate, all operations can be completed with just four buttons. The LCD display is convenient for users, and troubleshooting can be carried out based on error codes, resulting in minimal maintenance.
high precision
There are two ranges, namely 0.00-50.00 FTU and 50-1000 FTU.
LED light source
Using infrared light-emitting diodes (LEDs) as the light source. Compared with ordinary light sources, infrared LEDs have a long lifespan, stable emission intensity, and a peak value of 890nm. Even at low sample concentrations, they can ensure sufficient scattered light intensity and reduce chromatic interference, allowing for the measurement of turbidity in various colored samples.
Storage calibration date
The instrument has unique GLP functionality. GLP circuit automatically stores and retrieves calibration data. You can call up the latest calibration time, date, and calibration results at any time, making it convenient for users to confirm and approve the need for recalibration.
Equipped with RS232 interface, Three point calibration for 0FTU, 10FTU, and 500FTU, with built-in real-time clock.
It can store 500 sets of data and transmit data to a PC through the RS232 interface and HI92000 software.
Technical parameters of LP2000-11 high-performance microcomputer desktop turbidity meter:
model |
LP2000-11 |
measurement range |
0.00 to 50.00FTU & 50-1000FTU |
Resolution |
0.01&1FTU |
Precision |
The larger of ± 5% or ± 0.5 FTU of the reading |
EMC deviation |
±0.2FTU |
Light source |
LED, 890mm infrared light source |
Interface |
RS232 |
Data storage capability |
storage |
Real Time Clock |
have |
calibration method |
Adopting three-point calibration of 0FTU, 10FTU, and 500FTU |
battery |
12VDC power supply |
ambient temperature |
0 to 50℃,RH95% |
Size |
230×170×70mm/600g |
LP2000-11 turbidity meter optional models:
LP2000-11 |
Host, 12VDC transformer, two glass cuvettes, HI93703-0P (0FTU calibrated cuvette), HI93703-10P (10FTU calibrated cuvette), HI93703-05P (500FTU calibrated cuvette) cleaning solution cleaning cloth |
|
|
LP2000-11P |
Host, 12VDC transformer, two glass cuvettes, HI93703-0P (0FTU calibrated cuvette), HI93703-10P (10FTU calibrated cuvette), HI93703-05P (500FTU calibrated cuvette) cleaning solution cleaning cloth hard carrying case |
|